Integrating RGB-thermal image sensors for non-contact automatic respiration rate monitoring

被引:1
|
作者
Khanam, Fatema-Tuz-Zohra [1 ]
Perera, Asanka G. [2 ]
Al-Naji, Ali [1 ,3 ]
McIntyre, Timothy D. [1 ,4 ]
Chahl, Javaan [1 ,4 ]
机构
[1] Univ South Australia, STEM, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[2] Univ Southern Queensland, Sch Engn, Brisbane, Qld 4300, Australia
[3] Middle Tech Univ, Elect Engn Tech Coll, Baghdad 10022, Iraq
[4] Def Sci & Technol Grp, Platforms Div, Edinburgh, SA 5111, Australia
关键词
HEART-RATE; INFRARED THERMOGRAPHY; EXTRACTION; SYSTEM;
D O I
10.1364/JOSAA.520757
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Respiration rate (RR) holds significance as a human health indicator. Presently, the conventional RR monitoring system requires direct physical contact, which may cause discomfort and pain. Therefore, this paper proposes a non-contact RR monitoring system integrating RGB and thermal imaging through RGB-thermal image alignment. The proposed method employs an advanced image processing algorithm for automatic region of interest (ROI) selection. The experimental results demonstrated a close correlation and a lower error rate between measured thermal, measured RGB, and reference data. In summary, the proposed non-contact system emerges as a promising alternative to conventional contact-based approaches without the associated discomfort and pain. (c) 2024 Optica Publishing Group
引用
收藏
页码:1140 / 1151
页数:12
相关论文
共 50 条
  • [21] NON-CONTACT MONITORING OF PRETERM INFANTS USING RGB-D CAMERA
    Cenci, Annalisa
    Liciotti, Daniele
    Frontoni, Emanuele
    Mancini, Adriano
    Zingaretti, Primo
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 9, 2016,
  • [22] Non-contact Pulse Rate Measurement of Hand and Wrist Using RGB Camera
    Lu, Chi-Heng
    Low, Jen-Hua
    Tuan, Chiu-Ching
    ADVANCES ON BROADBAND AND WIRELESS COMPUTING, COMMUNICATION AND APPLICATIONS, BWCCA-2018, 2019, 25 : 586 - 596
  • [23] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Lalit Maurya
    Reyer Zwiggelaar
    Deepak Chawla
    Prasant Mahapatra
    Journal of Clinical Monitoring and Computing, 2023, 37 : 815 - 828
  • [24] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Maurya, Lalit
    Zwiggelaar, Reyer
    Chawla, Deepak
    Mahapatra, Prasant
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (03) : 815 - 828
  • [25] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [26] Non-contact Heart Rate Monitoring with Mobile Phone Camera
    Lin, Shu-Yen
    Tsai, Meng-Ru
    2019 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TW), 2019,
  • [27] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241
  • [28] Application of non-contact sensors for health monitoring in hospitals: a narrative review
    Choo, Yoo Jin
    Lee, Gun Woo
    Moon, Jun Sung
    Chang, Min Cheol
    FRONTIERS IN MEDICINE, 2024, 11
  • [29] Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
    Dosso, Yasmina Souley
    Greenwood, Kimberley J.
    Harrold, Joann
    Green, James R.
    IEEE ACCESS, 2023, 11 : 144168 - 144179
  • [30] Design and Realization of a Wideband Antenna for Non-Contact Respiration Monitoring in AAL Application
    Di Mattia, V.
    Petrini, V.
    Pallotta, E.
    De Leo, A.
    Pieralisi, M.
    Manfredi, G.
    Russo, P.
    Primiani, V. Mariani
    Cerri, G.
    Scalise, L.
    2014 IEEE/ASME 10TH INTERNATIONAL CONFERENCE ON MECHATRONIC AND EMBEDDED SYSTEMS AND APPLICATIONS (MESA 2014), 2014,