Effective Flange Width Based on Equivalence of Slab Crack Width at Hogging Moment Region of Composite Frame Beam

被引:0
|
作者
Tao, Mu-Xuan [1 ]
Zou, Ze-Bin [1 ]
Zhao, Ji-Zhi [2 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
steel-concrete composite structure; composite frame beam; hogging moment region; effective flange width; parameter sensitivity analysis;
D O I
10.3390/buildings14061708
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite structures have advantages in terms of strong bearing capacity and full utilisation of performance, and thus, composite frame beams are widely used in building construction. However, in the design and use of existing composite frame beams, the composite effect of a slab and steel beam cannot be completely taken into account. In this study, the effective flange width method is utilised to calculate the contribution of the slab reinforcement to the section moment of inertia to check the beam-end crack width via simulations using the general finite-element software MSC.MARC 2020. A parameter sensitivity analysis of the reinforcement tensile stress is conducted to determine critical influential geometric parameters for the side-column and centre-column hogging moment regions. Finally, design formulae for calculating the effective flange widths of the side- and centre-column hogging moment regions are proposed. In the formula for the side-column hogging moment region, the half column width (R) and steel-beam height (hs) are critical variables, whereas, in the formula for the centre-column hogging moment region, the steel-beam height (hs), slab width (bc), and half clear-span length (l) are critical variables. Both formulas are verified via a multiparameter simulation, which enables more accurate crack-checking calculations for the hogging moment region in the serviceability limit state. This study provides an important reference for fine finite-element simulations of serviceability limit states and shows the factors affecting the effective flange width that differ from those in the ultimate limit state.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Effective slab width in prestressed twin-girder composite decks
    Dezi, Luigino
    Gara, Fabrizio
    Leoni, Graziano
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2006, 132 (09): : 1358 - 1370
  • [32] STATIC STRUCTURAL PERFORMANCE OF CONTINUOUS COMPOSITE SLAB STRENGTHENED BY CFRP LAMINATE IN THE HOGGING MOMENT REGION
    Dahham, Khalid W.
    Baharom, Shahrizan
    Badaruzzaman, Wan Hamidon W.
    Muhammad, Norhasni
    Al-Zand, Ahmed W.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2018, 13 (06) : 1489 - 1499
  • [33] STUDY ON EFFECTIVE FLANGE WIDTH OF END OF CIRCULAR-SECTION-COLUMN COMPOSITE FRAME BEAM WITH NON-SYMMETRICAL STEEL SECTION AT ULTIMATE LIMIT STATE
    Peng W.-J.
    Tao M.-X.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (08): : 59 - 67and256
  • [34] Studies on Effective Width of Continuous Composite Beam of Arch Bridge
    Su, Qingtian
    Wang, Wei
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 1181 - 1186
  • [35] Effective width and rigidity of steel-concrete composite beam
    Nie, JG
    Tian, CY
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 64 - 71
  • [36] Effective slab width for beam-end flexural strength of composite frames with circular-section columns
    Zhao, Ji-Zhi
    Zhou, Qi-Liang
    Tao, Mu-Xuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 174 (174)
  • [37] Numerical evaluation for the effective slab width of steel-concrete composite beams
    Lasheen, Mahmoud
    Shaat, Amr
    Khalil, Ayman
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 148 : 124 - 137
  • [38] Crack width in negative moment area of continuous steel-concrete composite beams
    Qi, Lu-Kuan
    Li, Lin
    Chang, Jing
    Huo, Da
    Beijing Gongye Daxue Xuebao / Journal of Beijing University of Technology, 2008, 34 (07): : 714 - 719
  • [39] An Effective Beam Width Model of Slab in Thick Wall-Thick Slab Joints Subjected to Lateral Forces
    Wang, Jiehui
    Kusunoki, Koichi
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [40] Equivalent frame analysis for effective wall width of nonplanar beam-wall connections
    Behnam, Hamdolah
    Kuang, J. S.
    Huang, Qunxian
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (01):