Dual-mode detection of antibiotic drugs using ytterbium molybdate/porous carbon nanocomposite

被引:1
|
作者
Babulal, Sivakumar Musuvadhi [1 ]
Alagumalai, Krishnapandi [2 ]
Sivakumar, Mani [3 ]
Chen, Shen Ming [1 ]
Kim, Seong-Cheol [2 ]
Bharathi, Arumugam [2 ]
Babulal, Lakshmipriya Musuvadhi [4 ]
Karuppiah, Chelladurai [4 ]
Alothman, Asma A. [5 ]
Aldosari, Eman [5 ]
机构
[1] Natl Taipei Univ Technol, Coll Engn, Dept Chem Engn & Biotechnol, Taipei 10608, Taiwan
[2] Yeungnam Univ, Sch Chem Engn, Gyongsan 38541, South Korea
[3] Saveetha Univ, Saveetha Inst Med & Tech Sci, Saveetha Dent Coll & Hosp, Gen Pathol, Chennai 600077, Tamil Nadu, India
[4] Ming Chi Univ Technol, Battery Res Ctr Green Energy, New Taipei 24301, Taiwan
[5] King Saud Univ, Coll Sci, Chem Dept, Riyadh 11451, Saudi Arabia
来源
基金
新加坡国家研究基金会;
关键词
YbMO/PC; Metronidazole; Real-time approach; UV-vis spectrascopy analysis; Electrochemical sensor; ELECTROCHEMICAL SENSOR; GRAPHENE OXIDE; DEGRADATION; PERFORMANCE; CATALYST; METRONIDAZOLE; NANOPARTICLES; NANOSHEETS; NANOTUBES; COMPOSITE;
D O I
10.1016/j.jece.2024.112331
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Monitoring the levels of metronidazole (MTZ) is crucial to ensure the desired therapeutic effectiveness and to prevent potential harm to patients. However, MTZ exhibits concentration -dependent antimicrobial activity and has a narrow therapeutic range. In this study, "one stone two mango" strategy was influenced for the electrochemical and UV-vis spectroscopy detection of antibiotic residues of MTZ. The successfully synthesized ytterbium molybdate nano petals (YbMO) with porous carbon (PC) nanocomposite (NC) using ultrasonication method. The YbMO/PC NC, as well as other modified electrodes, were identified and targeted as molecules using natural pH as the probe to indicate current intensity. Also, examined the morphology and physicochemical properties of the synthesized materials. Furthermore, conducted cycling voltammetry (CV) and linear sweep voltammetry (LSV) on the modified electrodes to model MTZ analytes. Among them, the YbMO/PC NC/GCE exhibited larger reduction peak current and lower potential compared to other modified electrodes due to the synergistic effect between YbMO and PC, resulting in effective detection of MTZ. The YbMO/PC NC/GCE demonstrated exceptional sensitivity (3.28 mu A mu M-1 cm -2), a wide linear range (0.01-10.61 and 20.61-1630.61 mu M), and a remarkably low detection limit (LOD: 0.006 mu M). The proposed YbMO/PC NC/GCE exhibits the successfully analyzed MTZ in serum (101%), urine (97.9%), tablets (99.15%), lake (99.1%), and river water (99.8%). On the other hand, a UV-vis spectrometric method was employed to detect MTZ. The results showed a wide linear range (0.05-57.2 mu M) and an impressive LOD (70 nM). These results are attributed to the heightened sensitivity, selectivity, repeatability, and durability of the sensor.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Flexible Dual-Mode Tactile Sensor Derived from Three-Dimensional Porous Carbon Architecture
    Wang, Zifeng
    Jiang, Ruijuan
    Li, Guangming
    Chen, Yiyan
    Tang, Zijie
    Wang, Yukun
    Liu, Zhuoxin
    Jiang, Hongbo
    Zhi, Chunyi
    ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (27) : 22685 - 22693
  • [32] New dual-mode biquads using OTAs
    Bhaskar, D. R.
    Sharma, R. K.
    Singh, A. K.
    Senani, R.
    FREQUENZ, 2006, 60 (11-12) : 246 - 252
  • [33] Facile synthesis and ozonation of carbon dots using mango pulps for dual-mode colorimetry and ratiometric fluorescence detection of sarcosine
    Qin, Weidong
    Tian, Hongyuan
    Meng, Zhao
    Tang, Zhanqiu
    Wang, Junhua
    Wu, Zhenglong
    MICROCHEMICAL JOURNAL, 2023, 195
  • [34] Dual-Mode Multifunction Filter Using VDGAs
    Channumsin, Orapin
    Tangsrirat, Worapong
    2018 15TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2018, : 481 - 484
  • [35] Nitrogen-doped carbon dots/curcumin nanocomposite for combined Photodynamic/photothermal dual-mode antibacterial therapy
    Wen, Fangzhou
    Li, Peiyuan
    Meng, Hongrong
    Yan, Hongjun
    Huang, Xiaodong
    Cui, Hao
    Su, Wei
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 39
  • [36] Carbon Dot-Layered Double Hydroxide Nanocomposite with Dual-Mode Emission for Anti-Fake Application
    Wang, Xinrui
    Feng, Xiangnan
    Gao, Xuewei
    Liang, Kaixiang
    Shi, Wenying
    CHEMISTRYSELECT, 2022, 7 (27):
  • [37] Tough Porous Hydrogels for Ultrasensitive Naked-Eye and Fluorescence Dual-Mode Detection of Iron(III)
    Chen, Liang
    Li, Yao
    Zhang, Xincheng
    Cui, Yuanzhi
    Shi, Da
    Wang, Yan
    Rao, Ping
    Zhao, Liping
    Guo, Hua
    Guo, Mingming
    Ren, Wenshan
    ACS Applied Polymer Materials, 2024, 6 (23) : 14548 - 14556
  • [38] Fluorimetric and ratiometric colorimetric dual-mode detection of organophosphorus pesticides based on carbon dots/DTNB
    Feng, Yaoyao
    Qu, Yujiao
    Sun, Xiaobo
    Pan, Wei
    Wang, Jinping
    NEW JOURNAL OF CHEMISTRY, 2022, 46 (17) : 8022 - 8028
  • [39] Surface-functionalized fluorescent carbon dots (CDs) for dual-mode detection of lead ions
    Amy Bamrah
    Harpreet Singh
    Shalini Singh
    Sanjeev Kumar Bhardwaj
    Madhu Khatri
    Akash Deep
    Neha Bhardwaj
    Chemical Papers, 2022, 76 : 6193 - 6203
  • [40] Iron, Nitrogen-Doped Carbon Aerogels for Fluorescent and Electrochemical Dual-Mode Detection of Glucose
    Wu, Xingzi
    Sun, Yujie
    He, Ting
    Zhang, Yulin
    Zhang, Guo-Jun
    Liu, Qiming
    Chen, Shaowei
    LANGMUIR, 2021, 37 (38) : 11309 - 11315