Relationship between Intraocular Pressure Fluctuation and Visual Field Progression Rates in the United Kingdom Glaucoma Treatment Study

被引:5
|
作者
Rabiolo, Alessandro [1 ,2 ,3 ,4 ]
Montesano, Giovanni [1 ,2 ,5 ]
Crabb, David P. [5 ]
Garway-Heath, David F. [1 ,2 ]
机构
[1] Moorfields Eye Hosp, NIHR Biomed Res Ctr, London, England
[2] UCL Inst Ophthalmol, London, England
[3] Univ Hosp Maggiore Car, Ophthalmol Unit, Novara, Italy
[4] Univ Piemonte Orientale, Dept Hlth Sci, Novara, Italy
[5] City Univ London, Optometry & Visual Sci, London, England
关键词
Design: Randomized; double-masked; placebo-controlled multicenter trial; Ophthalmology; OCULAR PULSE AMPLITUDE; OPEN-ANGLE GLAUCOMA; RISK-FACTOR; BLOOD-FLOW; CORNEAL HYSTERESIS; TERM; THICKNESS; PARAMETER; RIGIDITY; IOP;
D O I
10.1016/j.ophtha.2024.02.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate whether intraocular pressure (IOP) fluctuation is associated independently with the rate of visual field (VF) progression in the United Kingdom Glaucoma Treatment Study. Design: Randomized, double-masked, placebo-controlled multicenter trial. Participants: Participants with >= 5 VFs (213 placebo, 217 treatment). Methods: Associations between IOP metrics and VF progression rates (mean deviation [MD] and five fastest locations) were assessed with linear mixed models. Fluctuation variables were mean Pascal ocular pulse amplitude (OPA), standard deviation (SD) of diurnal Goldmann IOP (diurnal fluctuation), and SD of Goldmann IOP at all visits (long-term fluctuation). Fluctuation values were normalized for mean IOP to make them independent from the mean IOP. Correlated nonfluctuation IOP metrics (baseline, peak, mean, supine, and peak phasing IOP) were combined with principal component analysis, and principal component 1 (PC1) was included as a covariate. Interactions between covariates and time from baseline modeled the effect of the variables on VF rates. Analyses were conducted separately in the two treatment arms. Main outcome measures: Associations between IOP fluctuation metrics and rates of MD and the five fastest test locations. Results: In the placebo arm, only PC1 was associated significantly with the MD rate (estimate, -0.19 dB/year [standard error (SE), 0.04 dB/year]; P < 0.001), whereas normalized IOP fluctuation metrics were not. No variable was associated significantly with MD rates in the treatment arm. For the fastest five locations in the placebo group, PC1 (estimate, -0.58 dB/year [SE, 0.16 dB/year]; P < 0.001), central corneal thickness (estimate, 0.26 dB/year [SE, 0.10 dB/year] for 10 mu m thicker; P = 0.01) and normalized OPA (estimate, -3.50 dB/year [SE, 1.04 dB/year]; P = 0.001) were associated with rates of progression; normalized diurnal and long-term IOP fluctuations were not. In the treatment group, only PC1 (estimate, -0.27 dB/year [SE, 0.12 dB/year]; P = 0.028) was associated with the rates of progression. Conclusions: No evidence supports that either diurnal or long-term IOP fluctuation, as measured in clinical practice, are independent factors for glaucoma progression; other aspects of IOP, including mean IOP and peak IOP, may be more informative. Ocular pulse amplitude may be an independent factor for faster glaucoma progression.
引用
收藏
页码:902 / 913
页数:12
相关论文
共 50 条
  • [41] Intraocular pressure (IOP) measured with the Ocular Response Analyzer is a better predictor of glaucoma progression than Goldmann IOP in the United Kingdom Glaucoma Treatment Study (UKGTS).
    Lascaratos, Gerassimos
    Garway-Heath, David F.
    Russell, Richard A.
    Crabb, David Paul
    Zhu, Haogang
    Hirn, Cornelia
    Kotecha, Aachal
    Suzuki, Katsuyoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [42] The advanced glaucoma intervention study (AGIS): 7. The relationship between control of intraocular pressure and visual field deterioration
    Van Veldhuisen, PC
    Ederer, F
    Gaasterland, DE
    Sullivan, EK
    Beck, A
    Prum, BE
    Cyrlin, MN
    Weiss, H
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (04) : 429 - 440
  • [43] Response to Letter to the Editor: Long-Term Intraocular Pressure Fluctuation is a Risk Factor for Visual Field Progression in Advanced Glaucoma
    Lee, Jihei Sara
    Park, Sungeun
    Seong, Gong Je
    Kim, Chan Yun
    Lee, Sang Yeop
    Choi, Wungrak
    Bae, Hyoung Won
    JOURNAL OF GLAUCOMA, 2023, 32 (05) : E41 - E42
  • [44] Visual field asymmetry is unrelated to intraocular pressure asymmetry in the low-pressure glaucoma treatment study
    Greenfield, DS
    Liebmann, JM
    Ritch, R
    Krupin, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [45] Surgery for normal tension glaucoma. Target intraocular pressure and visual field progression
    Fontana, L
    Viswanathan, AC
    Poinooswamy, D
    Hitchings, RA
    Scullica, L
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1997, 75 : 43 - 44
  • [46] Intraocular Pressure, Baseline Visual Field (VF) Mean Deviation (MD), and Glaucoma Progression
    Forchheimer, I.
    De Moraes, C. G.
    Folgar, F. A.
    Teng, C. C.
    Tello, C.
    Ritch, R.
    Liebmann, J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [47] Intraocular pressure fluctuation and glaucoma progression: what do we know?
    Leidl, Matthew C.
    Choi, Catherine J.
    Syed, Zeba A.
    Melki, Samir A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (10) : 1315 - 1319
  • [48] Distribution of Intraocular Pressure Measurements During Follow-up and its Relationship with Rates of Visual Field Progression
    Ghobraiel, Sara
    De Moraes, Gustavo V.
    Myers, Jonathan S.
    Liebmann, Jeffrey M.
    Ritch, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [49] Risk Factors for Visual Field Progression in the Low-pressure Glaucoma Treatment Study
    De Moraes, Carlos Gustavo
    Liebmann, Jeffrey M.
    Greenfield, David S.
    Gardiner, Stuart K.
    Ritch, Robert
    Krupin, Theodore
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (04) : 702 - 711
  • [50] Intraocular pressure and progression of visual field damage
    Brogliatti, B
    Rigault, R
    Palanza, L
    Savio, E
    Rolle, T
    Fea, A
    Merlo, SB
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 : 26 - 27