Development of an automatic surgical planning system for high tibial osteotomy using artificial intelligence

被引:0
|
作者
Miyama, Kazuki [1 ,2 ,3 ]
Akiyama, Takenori [1 ,3 ]
Bise, Ryoma [2 ]
Nakamura, Shunsuke [3 ]
Nakashima, Yasuharu [1 ]
Uchida, Seiichi [2 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, 3-1-1 Maidashi,Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Univ, Dept Adv Informat Technol, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
[3] Akiyama Clin, 2-28-39 Noke, Fukuoka, Fukuoka 8140171, Japan
来源
KNEE | 2024年 / 48卷
关键词
High tibial osteotomy; Surgical planning; Artificial intelligence; Deep learning; Automatic measurement; Lower-limb alignment parameters; TOTAL KNEE ARTHROPLASTY; OPENING-WEDGE; INTRAOBSERVER RELIABILITY; FOLLOW-UP; ALIGNMENT; OSTEOARTHRITIS; INTEROBSERVER;
D O I
10.1016/j.knee.2024.03.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study proposed an automatic surgical planning system for high tibial osteotomy (HTO) using deep learning -based artificial intelligence and validated its accuracy. The system simulates osteotomy and measures lower -limb alignment parameters in preand post-osteotomy simulations. Methods: A total of 107 whole -leg standing radiographs were obtained from 107 patients who underwent HTO. First, the system detected anatomical landmarks on radiographs. Then, it simulated osteotomy and automatically measured five parameters in preand post-osteotomy simulation (hip knee angle [HKA], weight -bearing line ratio [WBL ratio], mechanical lateral distal femoral angle [mLDFA], mechanical medial proximal tibial angle [mMPTA], and mechanical lateral distal tibial angle [mLDTA]). The accuracy of the measured parameters was validated by comparing them with the ground truth (GT) values given by two orthopaedic surgeons. Results: All absolute errors of the system were within 1.5 degrees or 1.5%. All inter -rater correlation confidence (ICC) values between the system and GT showed good reliability (>0.80). Excellent reliability was observed in the HKA (0.99) and WBL ratios (>0.99) for the preosteotomy simulation. The intra-rater difference of the system exhibited excellent reliability with an ICC value of 1.00 for all lower -limb alignment parameters in preand postosteotomy simulations. In addition, the measurement time per radiograph (0.24 s) was considerably shorter than that of an orthopaedic surgeon (118 s). Conclusion: The proposed system is practically applicable because it can measure lowerlimb alignment parameters accurately and quickly in preand post-osteotomy simulations. The system has potential applications in surgical planning systems. (c) 2024 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 137
页数:10
相关论文
共 50 条
  • [21] Development of Automatic Balancing Application for Fashion Company Using Artificial Intelligence
    Alrasheed, May
    Jmali, Mohamed
    Hamdi, Thouraya
    TEKSTILEC, 2024, 67 (03) : 210 - 224
  • [22] Digital Preoperative Planning for High Tibial Osteotomy using 2D Medical Imaging
    Awang, Norazimah
    Ahmad, Faudzi
    Rahaman, Rosnita A.
    Sulaiman, Riza
    Shapi'i, Azrulhizam
    Rashid, Abdul Halim Abdul
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2021, 12 (10) : 778 - 783
  • [23] Tibial slope and high tibial osteotomy using the circular external fixator
    Gunes, Taner
    Sen, Cengiz
    Erdem, Mehmet
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (02) : 192 - 198
  • [24] Digital planning of high tibial osteotomy. Interrater reliability by using two different software
    Schroeter, Steffen
    Ihle, Christoph
    Mueller, Johannes
    Lobenhoffer, Philipp
    Stoeckle, Ulrich
    van Heerwaarden, Ronald
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (01) : 189 - 196
  • [25] Tibial slope and high tibial osteotomy using the circular external fixator
    Taner Gunes
    Cengiz Sen
    Mehmet Erdem
    Knee Surgery, Sports Traumatology, Arthroscopy, 2007, 15 : 192 - 198
  • [26] Digital planning of high tibial osteotomy. Interrater reliability by using two different software
    Steffen Schröter
    Christoph Ihle
    Johannes Mueller
    Philipp Lobenhoffer
    Ulrich Stöckle
    Ronald van Heerwaarden
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 189 - 196
  • [27] System of Recommendation and Automatic Correction of Web Accessibility Using Artificial Intelligence
    Morillo, Paulina
    Chicaiza-Herrera, Diego
    Vallejo-Huanga, Diego
    ADVANCES IN USABILITY AND USER EXPERIENCE, 2020, 972 : 479 - 489
  • [28] Emergency consultation system with automatic response software using artificial intelligence
    Amagasa, Shunsuke
    Moriya, Takashi
    HEALTH POLICY AND TECHNOLOGY, 2022, 11 (03)
  • [29] Trajectory planning using artificial intelligence
    Eroglu, M.
    Gill, K.F.
    Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 1993, 207 (B3) : 193 - 198
  • [30] Automatic meal planning using artificial intelligence algorithms in computer aided diabetes therapy
    Bulka, J.
    Izworski, A.
    Koleszynska, J.
    Lis, J.
    Wochlik, I
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON AUTONOMOUS ROBOTS AND AGENTS, 2009, : 450 - 454