Development of an automatic surgical planning system for high tibial osteotomy using artificial intelligence

被引:0
|
作者
Miyama, Kazuki [1 ,2 ,3 ]
Akiyama, Takenori [1 ,3 ]
Bise, Ryoma [2 ]
Nakamura, Shunsuke [3 ]
Nakashima, Yasuharu [1 ]
Uchida, Seiichi [2 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, 3-1-1 Maidashi,Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Univ, Dept Adv Informat Technol, 744 Motooka,Nishi Ku, Fukuoka 8190395, Japan
[3] Akiyama Clin, 2-28-39 Noke, Fukuoka, Fukuoka 8140171, Japan
来源
KNEE | 2024年 / 48卷
关键词
High tibial osteotomy; Surgical planning; Artificial intelligence; Deep learning; Automatic measurement; Lower-limb alignment parameters; TOTAL KNEE ARTHROPLASTY; OPENING-WEDGE; INTRAOBSERVER RELIABILITY; FOLLOW-UP; ALIGNMENT; OSTEOARTHRITIS; INTEROBSERVER;
D O I
10.1016/j.knee.2024.03.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: This study proposed an automatic surgical planning system for high tibial osteotomy (HTO) using deep learning -based artificial intelligence and validated its accuracy. The system simulates osteotomy and measures lower -limb alignment parameters in preand post-osteotomy simulations. Methods: A total of 107 whole -leg standing radiographs were obtained from 107 patients who underwent HTO. First, the system detected anatomical landmarks on radiographs. Then, it simulated osteotomy and automatically measured five parameters in preand post-osteotomy simulation (hip knee angle [HKA], weight -bearing line ratio [WBL ratio], mechanical lateral distal femoral angle [mLDFA], mechanical medial proximal tibial angle [mMPTA], and mechanical lateral distal tibial angle [mLDTA]). The accuracy of the measured parameters was validated by comparing them with the ground truth (GT) values given by two orthopaedic surgeons. Results: All absolute errors of the system were within 1.5 degrees or 1.5%. All inter -rater correlation confidence (ICC) values between the system and GT showed good reliability (>0.80). Excellent reliability was observed in the HKA (0.99) and WBL ratios (>0.99) for the preosteotomy simulation. The intra-rater difference of the system exhibited excellent reliability with an ICC value of 1.00 for all lower -limb alignment parameters in preand postosteotomy simulations. In addition, the measurement time per radiograph (0.24 s) was considerably shorter than that of an orthopaedic surgeon (118 s). Conclusion: The proposed system is practically applicable because it can measure lowerlimb alignment parameters accurately and quickly in preand post-osteotomy simulations. The system has potential applications in surgical planning systems. (c) 2024 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 137
页数:10
相关论文
共 50 条
  • [1] Automatic Surgical Skill Assessment System Based on Concordance of Standardized Surgical Field Development Using Artificial Intelligence
    Igaki, Takahiro
    Kitaguchi, Daichi
    Matsuzaki, Hiroki
    Nakajima, Kei
    Kojima, Shigehiro
    Hasegawa, Hiro
    Takeshita, Nobuyoshi
    Kinugasa, Yusuke
    Ito, Masaaki
    JAMA SURGERY, 2023, 158 (08) : E231131
  • [2] A surgical planning and guidance system for high tibial osteotomies
    Tso, CY
    Ellis, RE
    Rudan, J
    Harrison, MM
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 39 - 50
  • [3] Imaging and preoperative planning for high tibial osteotomy
    Pape, D
    Seil, R
    Adam, F
    Rupp, S
    Kohn, D
    Lobenhoffer, P
    ORTHOPADE, 2004, 33 (02): : 122 - +
  • [4] Generic analytical osteotomy model for three-dimensional surgical planning in opening wedge high tibial osteotomy
    Choi, Dong-Kwon
    Koo, Bon-Yeol
    Park, Byoung-Keon
    Kim, Jay-Jung
    Park, Eun-Joo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (08) : 3877 - 3885
  • [5] Generic analytical osteotomy model for three-dimensional surgical planning in opening wedge high tibial osteotomy
    Dong-Kwon Choi
    Bon-Yeol Koo
    Byoung-Keon Park
    Jay-Jung Kim
    Eun-Joo Park
    Journal of Mechanical Science and Technology, 2016, 30 : 3877 - 3885
  • [6] The position of the lateral tibial spine and the implications for high tibial osteotomy planning
    Van Genechten, Wouter
    Mestach, Gino
    Vanneste, Yannick
    Van Haver, Annemieke
    Michielsen, Jozef
    Verdonk, Peter
    Claes, Steven
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (02): : 326 - 332
  • [7] Improvements in surgical technique of valgus high tibial osteotomy
    Lobenhoffer, P
    Agneskirchner, JD
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (03) : 132 - 138
  • [8] Improvements in surgical technique of valgus high tibial osteotomy
    Philipp Lobenhoffer
    Jens D. Agneskirchner
    Knee Surgery, Sports Traumatology, Arthroscopy, 2003, 11 : 132 - 138
  • [9] A CT-free intraoperative planning and navigation system for high tibial dome osteotomy
    Wang, GL
    Zheng, GY
    Grützner, PA
    von Recum, J
    Nolte, LP
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 2, PROCEEDINGS, 2004, 3217 : 610 - 620
  • [10] Wedge volume and osteotomy surface depend on surgical technique for high tibial osteotomy
    Dietrich Pape
    Klaus Dueck
    Manuel Haag
    Olaf Lorbach
    Romain Seil
    Henning Madry