A low-cost digital image correlation (DIC) system for measuring two-dimensional displacement fields is described. Using an off-the-shelf camera, lens, and open-source DIC analysis software, displacement fields in aluminum and steel dog-bone tensile specimens were measured. Correction for out-of-plane motion is used to obtain strains from the displacement fields. Proposed DIC strain measurement system is validated using conventional thin-film strain gauges for strains below 1%. Average strain measurements from the DIC system were found to be within 1% of the measurement obtained using strain gauges. For strains between 1% and 10%, strain histories from the DIC systems displayed excellent correlation with strain measurements obtained using an extensometer.
引用
收藏
页码:514 / 522
页数:9
相关论文
共 50 条
  • [31] Integration of fringe projection and two-dimensional digital image correlation for three-dimensional displacements measurements
    Felipe-Sese, Luis
    Lopez-Alba, Elias
    Siegmann, Philip
    Diaz, Francisco A.
    OPTICAL ENGINEERING, 2016, 55 (12)
  • [32] Low-Cost Plasmonic Platform for Photon-Emission Engineering of Two-Dimensional Semiconductors
    Singh, Anuj Kumar
    Mandal, Kishor K.
    Gupta, Yashika
    Anand, V. S. Abhay
    Eswaramoorthy, Lekshmi
    Kumar, Brijesh
    Kala, Abhinav
    Dixit, Saurabh
    Achanta, Venu Gopal
    Kumar, Anshuman
    PHYSICAL REVIEW APPLIED, 2023, 19 (04)
  • [33] Medical Simulators for Developing Countries Via Low-Cost Two-Dimensional Position Tracking
    Walz, Robin
    Meier, Zachary
    Winek, Michael
    Kowalewski, Timothy M.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2014, 8 (03):
  • [34] Two-dimensional non-recursive design method of low-cost FIR filter
    Zhong Y.
    Yan Y.
    Meng Z.
    Tian Y.
    Liu M.
    Li J.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2021, 53 (06): : 171 - 176and191
  • [35] Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera
    Kim, Seo Woo
    Ih, Jeong-Guon
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2018, 37 (02): : 99 - 109
  • [36] Improvement of Two-Dimensional Terahertz Image by Digital Image Processing
    Shon, Chae-Hwa
    Jin, Yun-Sik
    Jeon, Seuk-Gy
    Kim, Keun-Ju
    Jung, Sun-Shin
    Yong, Chong Won
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2005, 16 (06) : 500 - 507
  • [37] Accurate ex situ deformation measurement using an ultra-stable two-dimensional digital image correlation system
    Pan, Bing
    Yu, Liping
    Wu, Dafang
    APPLIED OPTICS, 2014, 53 (19) : 4216 - 4227
  • [38] Implementation of an Image Stitching Algorithm to a Low-Cost Digital Microscope
    Botan, Renan
    Coco, Klaus Fabian
    Komati, Karin Satie
    2017 30TH SIBGRAPI CONFERENCE ON GRAPHICS, PATTERNS AND IMAGES (SIBGRAPI), 2017, : 285 - 291
  • [39] A low-cost, portable, two-dimensional bioimpedance distribution estimation system based on the AD5933 impedance converter
    Munoz, Juan D.
    Mosquera, Victor H.
    Rengifo, Carlos F.
    HARDWAREX, 2022, 11
  • [40] LOW-COST DIGITAL SYSTEM FOR PHOTOINDUCED TRANSIENT SPECTROSCOPY
    BRASIL, MJSP
    PEDREIRA, PRB
    MOTISUKE, P
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (05) : 430 - 434