Research on propagation law of partial discharge ultrasonic signal in converter transformer

被引:1
|
作者
Duan, Hao [1 ]
Cheng, Lin [2 ,3 ]
Luo, Chuanxian [2 ,3 ]
Zhang, Jing [2 ,3 ]
Su, Zhonghuan [4 ]
机构
[1] State Grid Corp Ltd, Beijing 100031, Peoples R China
[2] State Grid Elect Power Res Inst Co LTD, Nanrui Grp, Nanjing 211106, Peoples R China
[3] Wuhan Nanrui Co LTD, State Grid Elect Power Res Inst, Wuhan 430074, Peoples R China
[4] Tbea Hengyang Transformer Co LTD, Hengyang 421007, Peoples R China
关键词
Electric transformer testing - Ultrasonic applications;
D O I
10.1063/5.0207346
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
When local discharge occurs inside the transformer, it will be accompanied by a burst sound to generate an ultrasonic signal, which can be used for fault monitoring and diagnosis inside the transformer. This paper focuses on studying the converter transformer and simulating and analyzing the location where local discharge is likely to occur in the converter transformer. The provided information includes the distribution of sound pressure within and outside the converter transformer and the impact of the winding on this distribution. Furthermore, the investigation focuses on the testing of local discharge in converter transformers using ultrasonic signals. A local discharge detection device for converter transformers has been developed. The experiment and analysis have been conducted, and what was learned was compared to the simulated outcomes. The determination of the local discharge position in converter transformers is based on the analysis of the time-varying waveform obtained at the observation point. This approach offers a novel method for finding and identifying local discharge.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Detection technology of partial discharge in transformer based on optical signal
    Jia, Shuangrui
    Jia, Yunfei
    Bu, Zewei
    Li, Simeng
    Lv, Liang
    Ji, Shengchang
    ENERGY REPORTS, 2023, 9 : 98 - 106
  • [32] Detection technology of partial discharge in transformer based on optical signal
    Jia, Shuangrui
    Jia, Yunfei
    Bu, Zewei
    Li, Simeng
    Lv, Liang
    Ji, Shengchang
    ENERGY REPORTS, 2023, 9 : 98 - 106
  • [33] Determination of partial discharge propagation and location in transformer windings using a hybrid transformer model
    Naderi, Mohammad S.
    Blackburn, T. R.
    Phung, B. T.
    Naderi, Mehdi S.
    Ghaemmaghami, R.
    Nasiri, A.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2007, 35 (06) : 607 - 623
  • [34] One Novel Type of UHF Antenna for Locating Partial Discharge and Simulation of UHF Signal Propagation within Transformer
    Zhu Chaojie
    Yin Yi
    Lu Yuncai
    Fei Yijun
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 1179 - 1182
  • [35] Study of Partial Discharge Ultrasonic Wave Propagation in Generator Stator
    Yang, Yongming
    Duan, Xu
    Jiang, Fan
    MECHATRONICS AND APPLIED MECHANICS, PTS 1 AND 2, 2012, 157-158 : 53 - 57
  • [36] Application of improved genetic algorithm in ultrasonic location of transformer partial discharge
    Zhu, Youchan
    Zhou, Li
    Xu, Haisheng
    NEURAL COMPUTING & APPLICATIONS, 2020, 32 (06): : 1755 - 1764
  • [37] Transformer Partial Discharge Detection Using Electical-Ultrasonic Technology
    Jiang, Wei
    Liu, Fan
    Wang, Zhiyuan
    Zhang, Xinghai
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [38] Application of improved genetic algorithm in ultrasonic location of transformer partial discharge
    Youchan Zhu
    Li Zhou
    Haisheng Xu
    Neural Computing and Applications, 2020, 32 : 1755 - 1764
  • [39] Ultrasonic position-setting measurement on partial discharge of power transformer
    Zhang, Fengying
    Wang, Yuguang
    Bianyaqi/Transformer, 2000, 37 (02): : 29 - 33
  • [40] Time-frequency Analysis Method for HF Partial Discharge Signal From Power Transformer Bushing Tap With Signal Propagation Characteristics
    Liu Y.
    Xie X.
    Luo X.
    Zhang L.
    Du Z.
    Liu, Yi (liuyi@sgepri.sgcc.com.cn), 1600, Science Press (46): : 594 - 602