The influence of radiographic marker registration versus a markerless trace registration method on the implant placement accuracy achieved by dynamic computer-assisted implant surgery. An in-vitro study

被引:1
|
作者
Jorba-Garcia, Adria [1 ]
Bara-Casaus, Jose Javier [2 ,3 ]
Camps-Font, Octavi [4 ,5 ]
Figueiredo, Rui [4 ,5 ]
Valmaseda-Castellon, Eduard [4 ,5 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, Spain
[2] Hosp Univ Sagrat Cor, Dent & Maxillofacial Inst, Grp Quirosalud, Barcelona, Spain
[3] Univ Barcelona, Univ Hosp Mutua Terrassa, Dept Oral & Maxillofacial Surg, Terrassa, Spain
[4] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg, Barcelona, Spain
[5] IDIBELL Inst, Barcelona, Spain
关键词
Computer-assisted surgery; Dental implants; Surgical navigation systems; Implant-Supported Dental Prosthesis; Accuracy; NAVIGATION;
D O I
10.1016/j.jdent.2024.105072
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study aimed to compare the effect the radiographic marker registration (RMR) and markerless tracing registration (MTR) on implant placement accuracy using a dynamic computer-assisted implant surgery system (dCAIS). Additionally, this study aimed to assess the surgical time and whether the implant location influences the accuracy of the two registration methods. Methods: 136 dental implants were randomly allocated to the RMR or MTR group and were placed with a dCAIS in resin models. Preoperative and postoperative Cone Beam Computer Tomograms (CBCT) were overlaid and implant placement accuracy was assessed. Descriptive and multivariate analysis of the data was performed. Results: Significant differences (P < 0.001) were found for all accuracy variables except angular deviation (RMR:4.30 degrees (SD:4.37 degrees); MTR:3.89 degrees (SD:3.32 degrees)). The RMR had a mean 3D platform deviation of 1.53 mm (SD:0.98 mm) and mean apex 3D deviation of 1.63 mm (SD:1.05 mm) while the MTR had lower values (0.83 mm (SD:0.67 mm) and 1.07 mm (SD:0.86 mm), respectively). In the MTR group, implant placement in the anterior mandible was more accurate (p < 0.05). Additionally, MTR did not significantly increase the surgical time compared with RMR (P = 0.489). Conclusions: MTR seems to increase the accuracy of implant placement using dCAIS in comparison with the RMR method, without increasing the surgical time. The operated area seems to be relevant and might influence the implant deviations. Clinical significance: Considering the limitations of this in-vitro study<bold>,</bold> MTR seems to provide a higher accuracy in implant placement using dCAIS without increasing the surgical time. Furthermore, this method does not require radiographic markers and allows re-registration during surgery.
引用
下载
收藏
页数:8
相关论文
共 46 条
  • [21] Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non- randomized prospective study
    Jaemsuwan, S.
    Arunjaroensuk, S.
    Kaboosaya, B.
    Subbalekha, K.
    Mattheos, N.
    Pimkhaokham, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (02) : 264 - 271
  • [22] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Feng, Yuzhang
    Su, Zhenya
    Mo, Anchun
    Yang, Xingmei
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [23] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Yuzhang Feng
    Zhenya Su
    Anchun Mo
    Xingmei Yang
    International Journal of Implant Dentistry, 8
  • [24] Comparison of the accuracy of implant placement using different drilling systems for static computer-assisted implant surgery: A simulation-based experimental study
    Sittikornpaiboon, Paknisa
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (04) : 635 - 643
  • [25] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Raabe, Clemens
    Schuetz, Tabea S.
    Chappuis, Vivianne
    Yilmaz, Burak
    Abou-Ayash, Samir
    Couso-Queiruga, Emilio
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01) : 4
  • [26] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Clemens Raabe
    Tabea S. Schuetz
    Vivianne Chappuis
    Burak Yilmaz
    Samir Abou-Ayash
    Emilio Couso-Queiruga
    International Journal of Implant Dentistry, 9
  • [27] Assessment of the Accuracy of Two Different Dynamic Navigation System Registration Methods for Dental Implant Placement in the Posterior Area: An In Vitro Study
    Wei, Tai
    Ma, Feifei
    Sun, Feng
    Ma, Yu
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (01):
  • [28] Accuracy of different registration areas using active and passive dynamic navigation systems in dental implant surgery: An in vitro study
    Wu, Bin-Zhang
    Ma, Fei-Fei
    Yan, Xiao-Yan
    Sun, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 888 - 897
  • [29] Influence of alveolar ridge morphology and guide-hole design on the accuracy of static Computer-Assisted Implant Surgery with two implant macro-designs: An in vitro study
    Dulla, Fabrice Alain
    Couso-Queiruga, Emilio
    Chappuis, Vivianne
    Yilmaz, Burak
    Abou-Ayash, Samir
    Raabe, Clemens
    JOURNAL OF DENTISTRY, 2023, 130
  • [30] Accuracy of dental implant placement using augmented reality-based navigation, static computer assisted implant surgery, and the free-hand method: An in vitro study
    Kivovics, Marton
    Takacs, Anna
    Penzes, Dorottya
    Nemeth, Orsolya
    Mijiritsky, Eitan
    JOURNAL OF DENTISTRY, 2022, 119