Reinforcing resilience for integrated design of green and grey infrastructure with real-time control rules by considering system failures

被引:0
|
作者
Luo, Xinran [1 ,2 ,3 ]
Liu, Pan [1 ,2 ,3 ]
Cheng, Qian [1 ,2 ,3 ]
Liu, Weibo [1 ,2 ,3 ]
Zhou, Chutian [1 ,2 ,3 ]
Zheng, Yalian [1 ,2 ,3 ]
Wang, Dianchang [4 ]
Cheng, Lei [1 ,2 ,3 ]
机构
[1] Wuhan Univ, State Key Lab Water Resources Engn & Management, Wuhan 430072, Peoples R China
[2] Wuhan Univ, Hubei Prov Key Lab Water Syst Sci Sponge City Cons, Wuhan 430072, Peoples R China
[3] Wuhan Univ, Res Inst Water Secur RIWS, Wuhan 430072, Peoples R China
[4] Yangtze Ecol & Environm Co Ltd, Wuhan 430072, Peoples R China
基金
国家重点研发计划;
关键词
Urban drainage systems; Green and grey infrastructure; Real-time control; Equipment and structural failures; Resilience; URBAN DRAINAGE SYSTEMS; PERFORMANCE; MANAGEMENT; MODEL;
D O I
10.1016/j.jhydrol.2024.131498
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The mutual benefits of real-time control and green and grey infrastructure for urban drainage system (UDS) renovations have drawn great attention. However, risks emerged due to equipment and structural failures, and no studies considered such failures while optimizing the renovation scheme. To address this issue, this study proposed a multi -criteria optimization method for the integrated design of green and grey infrastructure with real-time control rules, where the economic cost and system performance under normal and exceptional conditions were optimized simultaneously. Failure probabilities of equipment and structure were quantified using homogeneous Poisson process models, and failure losses were estimated with the aid of a machine learning -based surrogate model. This approach was tested with a combined UDS in China. Results indicate that: (1) More investment does not necessarily increase system resilience to failures. Equipment and structural failures can significantly lower the effectiveness of grey infrastructure and real-time control. Therefore, solutions with more investments in grey infrastructure, which indicate higher costs, experience greater failure losses. (2) System resilience to failures can be significantly improved while maintaining other objectives when compared with the traditional design scheme. The proposed method allows for a new perspective in addition to the cost -andresilience two -objectives design of UDS renovations, especially for systems threatened by various failures.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Real-time control of pig growth through an integrated management system
    Parsons, D. J.
    Green, D. M.
    Schofield, C. P.
    Whittemore, C. T.
    BIOSYSTEMS ENGINEERING, 2007, 96 (02) : 257 - 266
  • [32] An integrated system for real-time Model Predictive Control of humanoid robots
    Erez, Tom
    Lowrey, Kendall
    Tassa, Yuval
    Kumar, Vikash
    Kolev, Svetoslav
    Todorov, Emanuel
    2013 13TH IEEE-RAS INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2013, : 292 - 299
  • [33] Implementation of a real-time integrated control system in a freeway/arterial corridor
    Rindt, CR
    Jayakrishnan, R
    McNally, MG
    TRANSPORTATION SYSTEMS 1997, VOLS 1-3, 1997, : 1097 - 1102
  • [34] A real-time state estimation framework for integrated energy system considering measurement delay
    Xu, Dongliang
    Xu, Junjun
    Wu, Zaijun
    Hu, Qinran
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (14) : 2891 - 2902
  • [35] Design of Real-Time Dynamic Reversible Lane in Intelligent Cooperative Vehicle Infrastructure System
    Mao, Lina
    Li, Wenquan
    Hu, Pengsen
    Zhou, Guiliang
    Zhang, Huiting
    Dai, Jin
    Journal of Advanced Transportation, 2020, 2020
  • [36] System Design and Performance Analysis of Indoor Real-time Localization using UWB Infrastructure
    Plangger, Jonathan
    Ravichandran, Hari Govindasamy
    Rodin, Sarat Chandran
    Atia, Mohamed
    2023 IEEE INTERNATIONAL SYSTEMS CONFERENCE, SYSCON, 2023,
  • [37] Design of Real-Time Dynamic Reversible Lane in Intelligent Cooperative Vehicle Infrastructure System
    Mao, Lina
    Li, Wenquan
    Hu, Pengsen
    Zhou, Guiliang
    Zhang, Huiting
    Dai, Jin
    JOURNAL OF ADVANCED TRANSPORTATION, 2020, 2020
  • [38] Design and Implementation of an Integrated Environment for Real-Time Control of Power Electronic Systems
    Tuncer, Servet
    Tatar, Yetkin
    Guldemir, Hanifi
    COMPUTER APPLICATIONS IN ENGINEERING EDUCATION, 2009, 17 (02) : 119 - 130
  • [39] The design of Real-time Distributed Arrival Time Control System in a cell manufacturing
    Gao, Bin
    Gong, Jun
    Li, Qian
    Tang, Jiafu
    2011 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, 2011, : 1518 - +
  • [40] Implementation of a modern real-time control infrastructure for supporting the Brazilian interconnected power system
    Ribeiro, C
    Moszkowicz, M
    de Silveira, AF
    Céspedes, R
    Cáceres, D
    PICA 2001: 22ND IEEE POWER ENGINEERING SOCIETY INTERNATIONAL CONFERENCE ON POWER INDUSTRY COMPUTER APPLICATIONS, 2001, : 148 - 154