Inter-rater-reliability, intra-rater-reliability and validity of clinical tests to assess cervical spine motor control abilities: A systematic review of diagnostic accuracy studies

被引:0
|
作者
Engelmann, Bernard [1 ]
Switters, Jacob Marten [2 ]
Luomajoki, Hannu [3 ]
机构
[1] Physiotherapie Team Spittelau, Stadtbahnbogen 348,Heiligenstadterstr 31, A-1190 Vienna, Austria
[2] JMS Praxis, Markgraf Rudiger Str 25-5, A-1150 Vienna, Austria
[3] Zurich Univ Appl Sci, ZHAW Inst Physiotherapy, Dept Hlth, Katharina Sulzer Pl 9 CH, CH-8401 Winterthur, Switzerland
关键词
Cervical motor control; Diagnostics; Physical examination; Neck pain; Systematic review; LOW-BACK-PAIN; CRANIOCERVICAL FLEXION TEST; CHRONIC NECK PAIN; MOVEMENT CONTROL; MUSCULOSKELETAL PAIN; FEAR-AVOIDANCE; PERFORMANCE; INDIVIDUALS; DYSFUNCTION; GUIDELINE;
D O I
10.1016/j.jbmt.2024.01.026
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Research into the aetiology of spinal pain has shown a clear tendency towards a sensorimotor control perspective. In contrast to the lumbar spine, the available motor control tests for the cervical spine are extremely varied, little studied and sometimes very costly. Objective: Review the quality and choice of the available cervical spine motor control tests. The diagnostic accuracy of the current low technology motor control tests was evaluated in a systematic review. Method: A search for reliability and discriminative validity studies was conducted in the Pubmed MEDLINE (R) database (NCBI) and the Cochrane Central Register of Controlled Trials, according to the PRISMA-DTA protocol. Quality Appraisal for Reliability Studies (QAREL) and Standards for Reporting Diagnostic accuracy studies (STARD) were conducted to assess the quality of the included studies. The statistical parameters of ICC, kappa-value, sensitivity, specificity, Diagnostic Odds Ratio, Area Under the Curve, mean, standard deviation and/or the confidence interval were extracted. Results: Two movement control test batteries, one head-eye-coordination test battery and the craniocervical flexion test were found to be standing out in terms of reliability, validity, applicability and cost-effectiveness (Kappa and ICC scores >0.8 for reliability and AUC 0,83 for validity.) Discussion: To date only one study was published for each of the test batteries. Nevertheless, the risk of bias compared to all other cervical motor control tests found was significantly lower. Moreover, the application is possible completely without technical equipment, which makes the findings of the present work accessible to the majority of healthcare professionals.
引用
收藏
页码:674 / 682
页数:9
相关论文
共 42 条
  • [1] Inter- and intra-rater-reliability of a clinical framework for spine-related neck-arm pain
    Kapitza, C.
    Luedtke, K.
    Komenda, M.
    Kiefhaber, M.
    Schmid, A. B.
    Ballenberger, N.
    Tampin, B.
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2023, 67
  • [2] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Moll, Line Thorndal
    Kindt, Morten Wasmod
    Stapelfeldt, Christina Malmose
    Jensen, Tue Secher
    CHIROPRACTIC & MANUAL THERAPIES, 2018, 26
  • [3] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Line Thorndal Moll
    Morten Wasmod Kindt
    Christina Malmose Stapelfeldt
    Tue Secher Jensen
    Chiropractic & Manual Therapies, 26
  • [4] Assessment of the posture of adolescents in everyday clinical practice: Intra-rater and inter-rater reliability and validity of a posture index
    Ludwig, Oliver
    Hammes, Annette
    Kelm, Jens
    Schmitt, Eduard
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2016, 20 (04) : 761 - 766
  • [5] Intra- and inter-rater reliability of movement and palpation tests in patients with neck pain: A systematic review
    Jonsson, Anders
    Rasmussen-Barr, Eva
    PHYSIOTHERAPY THEORY AND PRACTICE, 2018, 34 (03) : 165 - 180
  • [6] Screening of the spine in adolescents: inter- and intra-rater reliability and measurement error of commonly used clinical tests
    Aartun, Ellen
    Degerfalk, Anna
    Kentsdotter, Linn
    Hestbaek, Lise
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [7] Screening of the spine in adolescents: inter- and intra-rater reliability and measurement error of commonly used clinical tests
    Ellen Aartun
    Anna Degerfalk
    Linn Kentsdotter
    Lise Hestbaek
    BMC Musculoskeletal Disorders, 15
  • [8] Education of physiotherapists improves inter-rater reliability in lumbar spine motor control tests: A randomized controlled trial
    Riese, Daniel
    Kool, Jan
    Sieben, Judith
    de Bie, Rob
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2023, 64
  • [9] Diagnostic validity, accuracy and inter-rater reliability of a phonological assessment for Danish-speaking children
    Clausen, Marit C.
    Fox-Boyer, Annette, V
    JOURNAL OF COMMUNICATION DISORDERS, 2022, 95
  • [10] The Inter-Rater Reliability and Diagnostic Accuracy of Patellar Mobility Tests in Patients with Anterior Knee Pain
    Sweitzer, Brett A.
    Cook, Chad
    Steadman, J. Richard
    Hawkins, Richard J.
    Wyland, Douglas J.
    PHYSICIAN AND SPORTSMEDICINE, 2010, 38 (03): : 90 - 96