Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study

被引:11
|
作者
Moll, Line Thorndal [1 ,2 ,3 ]
Kindt, Morten Wasmod [4 ]
Stapelfeldt, Christina Malmose [1 ,2 ]
Jensen, Tue Secher [4 ,5 ]
机构
[1] DEFACTUM, PP Oerums Gade 11,Bygn 1B, DK-8000 Aarhus C, Cent Denmark Re, Denmark
[2] Aarhus Univ, Sect Clin Social Med & Rehabil, Dept Publ Hlth, PP Oerums Gade 9-11,Bygn 1B, DK-8000 Aarhus C, Denmark
[3] Silkeborg Reg Hosp, Univ Res Clin Innovat Patient Pathways, Diagnost Ctr, Spine Ctr, Falkevej 1-3, DK-8600 Silkeborg, Denmark
[4] Silkeborg Reg Hosp, Univ Res Clin Innovat Patient Pathways, Diagnost Ctr, Dept Diagnost Imaging, Falkevej 1-3, DK-8600 Silkeborg, Denmark
[5] Univ Southern Denmark, Nord Inst Chiropract & Clin Biomechan, Campusvej 55, DK-5230 Odense M, Denmark
关键词
Magnetic resonance imaging; Reliability; Cervical spine; Degenerative; Classification; MRI; Agreement; GRADING SYSTEM; DISC; STENOSIS; AGREEMENT; PATIENT; TROPISM;
D O I
10.1186/s12998-018-0210-2
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
BackgroundKnowledge about the assessment reliability of common cervical spine changes is a prerequisite for precise and consistent communication about Magnetic Resonance Imaging (MRI) findings. The purpose of this study was to determine the inter- and intra-rater reliability of degenerative findings when assessing cervical spine MRI.MethodsFifty cervical spine MRIs from subjects with neck pain were used. A radiologist, a chiropractor and a second-year resident of rheumatology independently assessed kyphosis, disc height, disc contour, vertebral endplate signal changes, spinal canal stenosis, neural foraminal stenosis, and osteoarthritis of the uncovertebral and zygapophyseal joints. An evaluation manual was composed containing classifications and illustrative examples, and ten of the MRIs were evaluated twice followed by consensus meetings to refine the classifications. Next, the three readers independently assessed the full sample. Reliability measures were reported using prevalence estimates and unweighted kappa () statistics.ResultsThe overall inter-rater reliability was substantial (0.61) for the majority of variables and moderate only for zygapophyseal osteoarthritis (=0.56). Intra-rater reliability estimates were higher for all findings.ConclusionsThe present classifications for some of the most common cervical degenerative findings yielded mainly substantial inter-rater reliability estimates and substantial to almost perfect intra-rater reliability estimates. .Trial registrationRegional Data Protection Agency (J.no. 1-16-02-86-16). The letter of exemption from the Regional Ethical Committee is available from the author on request (case no. 86 / 2017).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Line Thorndal Moll
    Morten Wasmod Kindt
    Christina Malmose Stapelfeldt
    Tue Secher Jensen
    [J]. Chiropractic & Manual Therapies, 26
  • [2] Inter- and intra-rater reliability of cervical auscultation to detect aspiration in patients with dysphagia
    Stroud, AE
    Lawrie, BW
    Wiles, CM
    [J]. CLINICAL REHABILITATION, 2002, 16 (06) : 640 - 645
  • [3] INTER- AND INTRA-RATER RELIABILITY IN THE DIAGNOSIS AND STAGING OF ENDOMETRIOSIS
    Schliep, K.
    Stanford, J.
    Chen, Z.
    Zhang, B.
    Dorais, J.
    Johnstone, E.
    Hammoud, A.
    Varner, M.
    Louis, G. Buck
    Peterson, M.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2012, 175 : S137 - S137
  • [4] Finger circumference measurements: inter- and intra-rater reliability
    Lewis, Erika S.
    [J]. HAND THERAPY, 2010, 15 (03) : 69 - 72
  • [5] Test-retest, inter- and intra-rater reliability of the flexicurve for evaluation of the spine in children
    Sedrez, Juliana A.
    Candotti, Claudia T.
    Rosa, Maria I. Z.
    Medeiros, Fernanda S.
    Marques, Mariana T.
    Loss, Jefferson F.
    [J]. BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2016, 20 (02) : 142 - 147
  • [6] Inter- and intra-rater reliability of carpal tunnel volume measurement
    Anderson, Drew A.
    Miller, Mackenzie J.
    Agur, Anne M.
    Oliver, Michele L.
    Gordon, Karen D.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2022, 10 (02): : 211 - 216
  • [7] Inter- and intra-rater reliability of fluoroscopic cough stress testing
    Glancz, L. J.
    Cartwright, R.
    Cardozo, L.
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2010, 30 (05) : 492 - 495
  • [8] Inter- and Intra-Rater Reliability of the Visual Vertical in Subacute Stroke
    Piscicelli, Celine
    Barra, Julien
    Davoine, Patrice
    Chrispin, Anne
    Nadeau, Sylvie
    Perennou, Dominic
    [J]. STROKE, 2015, 46 (07) : 1979 - 1983
  • [9] Inter- and intra-rater reliability of nasal auscultation in daycare children
    Santos, Rita
    Alexandrino, Ana Silva
    Tome, David
    Melo, Cristina
    Montes, Antonio Mesquita
    Costa, Daniel
    Ferreira, Joao Pinto
    [J]. MINERVA PEDIATRICA, 2018, 70 (01) : 20 - 26
  • [10] Inter- and Intra-Rater Reliability of Neck Circumference Measurements in Children
    LaBerge, Robert C.
    Vaccani, Jean Philippe
    Gow, Robert M.
    Gaboury, Isabelle
    Hoey, Lynda
    Katz, Sherri L.
    [J]. PEDIATRIC PULMONOLOGY, 2009, 44 (01) : 64 - 69