Dosimetric characteristics of self-expandable metallic and plastic stents for transpapillary biliary decompression in external beam radiotherapy

被引:0
|
作者
Ueda, Yoshihiro [1 ]
Ikezawa, Kenji [2 ]
Sagawa, Tomohiro [1 ]
Isono, Masaru [1 ]
Ohira, Shingo [1 ]
Miyazaki, Masayoshi [1 ]
Takada, Ryoji [2 ]
Yamai, Takuo [2 ]
Ohkawa, Kazuyoshi [2 ]
Teshima, Teruki [3 ]
Konishi, Koji [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, 3-1-69 Otemae,Chuo Ku, Osaka 5378567, Japan
[2] Osaka Int Canc Inst, Dept Hepatobiliary & Pancreat Oncol, 3-1-69 Otemae,Chuo Ku, Osaka 5378567, Japan
[3] Osaka Heavy Ion Therapy Ctr, Dept Radiat Oncol, 3-1-10 Otemae,Chuo Ku, Osaka 5400008, Japan
关键词
Pancreatobiliary; Radiotherapy; Self-expandable metallic stents; Plastic stents; Radiopaque markers; DOSE PERTURBATION; NEOADJUVANT CHEMORADIATION; INDUCTION CHEMOTHERAPY; CANCER-PATIENTS; PHASE-II; RADIATION; CHEMORADIOTHERAPY; OBSTRUCTION; PLACEMENT; THERAPY;
D O I
10.1007/s13246-024-01447-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is little evidence regarding radiation dose perturbation caused by the self-expandable metallic stents (SEMSs) used for transpapillary biliary decompression. We aimed to compare SEMSs with plastic stents (PSs) and clarify their dosimetric characteristics. Fifteen SEMSs (10 braided and 5 lasercut type) and six PSs (diameter: 2.3-3.3 mm) were inserted into a water-equivalent solid phantom. In total, 13 SEMSs had radiopaque markers, whereas the other two did not. Using radiochromic films, the dose difference adjacent to the stents at locations proximal, distal, and arc delivery to the radiation source was evaluated based on comparison to measurement of the dose delivery in phantom without any stent in place. The median values of the dose difference for each stent were used to compare the SEMS and PS groups.Results: The dose difference (median (minimum/maximum)) was as follows: proximal, SEMSs + 2.1% (1.8 / 4.7) / PSs + 5.4% (4.1 / 6.3) (p < 0.001); distal, SEMSs -1.0% (-1.6 /-0.4) / PSs -8.9% (-11.7 / -7.4) (p < 0.001); arc delivery, SEMSs 1.2% (0.9 / 2.3) / PSs 2.2% (1.6 / 3.6) (p = 0.005). These results demonstrated that the dose differences of SEMSs were significantly smaller than those of PSs. On the other hand, the dose difference was large at surface of the radiopaque markers for SEMSs: proximal, 10.3% (7.2 / 20.9); distal, -8.4% (-16.3 / -4.2); arc delivery, 5.5% (4.2 / 9.2). SEMSs for biliary decompression can be safely used in patients undergoing radiotherapy, by focusing on the dose distribution around the stents and by paying attention to local changes in the dose distribution of radiopaque markers.
引用
收藏
页码:1323 / 1335
页数:13
相关论文
共 50 条
  • [1] PREOPERATIVE BILIARY DECOMPRESSION PRECEDING PANCREATICODUODENECTOMY WITH PLASTIC OR SELF-EXPANDABLE METALLIC STENT
    Haapamaki, C.
    Seppanen, H.
    Udd, M.
    Juuti, A.
    Halttunen, J.
    Kiviluoto, T.
    Siren, J.
    Mustonen, H.
    Kylanpaa, L.
    SCANDINAVIAN JOURNAL OF SURGERY, 2015, 104 (02) : 79 - 85
  • [2] Novel characteristics of traction force in biliary self-expandable metallic stents
    Hori, Yasuki
    Hayashi, Kazuki
    Yoshida, Michihiro
    Naitoh, Itaru
    Ban, Tesshin
    Miyabe, Katsuyuki
    Kondo, Hiromu
    Nishi, Yuji
    Umemura, Shuichiro
    Fujita, Yasuaki
    Natsume, Makoto
    Kato, Akihisa
    Ohara, Hirotaka
    Joh, Takashi
    DIGESTIVE ENDOSCOPY, 2017, 29 (03) : 347 - 352
  • [3] Covered Self-Expandable Metallic Stents versus Multiple Plastic Stents for Benign Biliary Strictures
    Nayfeh, Tarek
    Majzoub, Abdul Monaem
    Aboursheid, Tarek
    Malik, Alexander
    Osman, Karim T.
    Hassett, Leslie C.
    Noureddin, Nabil
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S1151 - S1151
  • [4] Self-expandable metallic biliary stents with permanent access
    Ho, CS
    Voss, MD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 410 - 414
  • [5] Self-expandable metallic stents vs. plastic stents for endoscopic biliary drainage in hepatocellular carcinoma
    Chung, Kwang Hyun
    Lee, Sang Hyub
    Park, Jin Myung
    Lee, Jae Min
    Ahn, Dong-Won
    Ryu, Ji Kon
    Kim, Yong-Tae
    ENDOSCOPY, 2015, 47 (06) : 509 - 517
  • [6] Superiority of Self-Expandable Metallic Stents Over Plastic Stents in Treatment of Malignant Distal Biliary Strictures
    Jang, Sunguk
    Stevens, Tyler
    Parsi, Mansour A.
    Bhatt, Amit
    Kichler, Adam
    Vargo, John J.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2022, 20 (02) : E182 - E195
  • [7] Percutaneous self-expandable metallic stents and malignant biliary strictures
    Hamy, A
    dAlincourt, A
    Paineau, J
    Lerat, F
    Gibaud, H
    Leborgne, J
    Visset, J
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1997, 23 (05): : 403 - 408
  • [8] MALIGNANT BILIARY OBSTRUCTION - TREATMENT WITH SELF-EXPANDABLE METALLIC STENTS
    CUMHUR, T
    OZMEN, MN
    AKHAN, O
    OLCER, T
    CEKIRGE, S
    OZDEMIR, E
    EUROPEAN RADIOLOGY, 1995, 5 (01) : 6 - 12
  • [9] Self-expandable metallic stents in the management of malignant biliary obstruction
    Tsai, CC
    Mo, LR
    Lin, RC
    Kuo, JY
    Chang, KK
    Yeh, YH
    Yang, SC
    Yueh, SK
    Tsai, HM
    Yu, CY
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1996, 95 (04) : 298 - 302
  • [10] Percutaneous self-expandable metallic stents and malignant biliary strictures
    d'Alincourt, A
    Lerat, F
    Gibaud, H
    Paineau, J
    Leborgne, J
    Visset, J
    JOURNAL DE RADIOLOGIE, 1998, 79 (01): : 39 - 43