Lab-made CO2 laser-engraved electrochemical sensors for ivermectin determination

被引:0
|
作者
Ferreira, Dianderson C. M. [1 ]
Inoque, Nelio I. G. [2 ]
Tanaka, Auro Atsushi [1 ]
Dantas, Luiza M. F. [1 ]
Munoz, Rodrigo A. A. [2 ]
da Silva, Iranaldo S. [1 ]
机构
[1] Univ Fed Maranhao, Chem Technol Dept, BR-65080805 Sao Luis, Maranhao, Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38408100 Uberlandia, MG, Brazil
关键词
GRAPHENE;
D O I
10.1039/d4ay00414k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ivermectin (IVM), as a broad-spectrum antiparasitic drug, was widely prescribed to treat COVID-19 during the pandemic, despite lacking proven efficacy in combating this disease. Therefore, it is important to establish affordable devices in laboratories with minimal infrastructure. The laser engraving technology has been revolutionary in sensor manufacturing, primarily attributed to the diversity of substrates that can be employed and the freedom it provides in creating sensor models. In this work, electrochemical sensors based on graphene were developed using the laser engraving technology for IVM sensing. Through, the studies that used the techniques of cyclic voltammetry and differential pulse voltammetry, following parameter optimization, for the laser-induced graphene electrode demonstrated a mass transport governed by adsorption of the species and exhibited a linear working range of 10-100 (mu mol L-1), a limit of detection (LOD) of 1.6 x 10(-6) (mol L-1), a limit of quantification (LOQ) of 4.8 x 10(-6) (mol L-1), and a sensitivity of 0.139 (mu A mu mol L-1). The developed method was successfully applied to direct analysis of pharmaceutical tablets, tap water (recovery of 94%) and synthetic urine samples (recovery between 97% and 113%). These results demonstrate the feasibility of the method for routine analyses involving environmental samples.
引用
收藏
页码:4136 / 4142
页数:7
相关论文
共 50 条
  • [21] CO2 Laser Manufacturing of Miniaturised Lenses for Lab-on-a-Chip Systems
    Mohammed, Mazher-Iqbal
    Desmulliez, Marc Phillipe Yves
    [J]. MICROMACHINES, 2014, 5 (03): : 457 - 471
  • [22] Electrochemical sensors based on proton-conducting electrolytes for determination of concentration and diffusion coefficient of CO2 in inert gases
    Kalyakin, Anatoly S.
    Medvedev, Dmitry A.
    Volkov, Alexander N.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2021, 229
  • [23] Quantification of a subsea CO2 release with lab-on-chip sensors measuring benthic gradients
    Schaap, Allison
    Koopmans, Dirk
    Holtappels, Moritz
    Dewar, Marius
    Arundell, Martin
    Papadimitriou, Stathys
    Hanz, Rudolf
    Monk, Samuel
    Mowlem, Matthew
    Loucaides, Socratis
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2021, 110 (110)
  • [24] Efficiency determination of the laser-induced reaction of NO(A(2Σ+)) with CO2
    Codnia, J.
    Manzano, F. A.
    Azcarate, M. L.
    [J]. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2011, 223 (01) : 65 - 69
  • [25] Cutting depth determination within CO2 laser micromachining
    Sykorova, L.
    [J]. Annals of DAAAM for 2006 & Proceedings of the 17th International DAAAM Symposium: INTELLIGENT MANUFACTURING & AUTOMATION: FOCUS ON MECHATRONICS AND ROBOTICS, 2006, : 405 - 406
  • [26] A new Bluetooth-assisted sensor based on lab-made screen-printed electrode modified with Ni-Ag 2 S for electrochemical detection of triclosan
    Cetiner, Rumeysa
    Sarilmaz, Adem
    Ozel, Faruk
    Bas, Salih Zeki
    Ozmen, Mustafa
    [J]. ELECTROCHIMICA ACTA, 2024, 489
  • [27] Measurement of the Nonlinearity of Heat-Flux Sensors Employing a CO2 laser
    van der Ham, E. W. M.
    Beer, C. M.
    Ballico, M. J.
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2018, 39 (01)
  • [28] Traceable dynamic calibration for high temperature sensors using CO2 laser
    Zhou, Hanchang
    Hao, Xiaojian
    Chen, Wedi
    Huang, Liang
    [J]. 2006 IEEE SENSORS, VOLS 1-3, 2006, : 1349 - +
  • [29] Extremely deep long-period fiber grating made with CO2 laser
    Slavik, Radan
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2006, 18 (13-16) : 1705 - 1707
  • [30] Sulfanilamide Electrochemical Sensor Using Phenolic Substrates and CO2 Laser Pyrolysis
    de Farias, Davi M.
    Pradela-Filho, Lauro A.
    Arantes, Iana V. S.
    Gongoni, Juliana L. M.
    Veloso, William B.
    Meloni, Gabriel N.
    Paixao, Thiago R. L. C.
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (48) : 56424 - 56432