Unravelling Influence Factors in Pattern Recognition Myoelectric Control Systems: The Impact of Limb Positions and Electrode Shifts

被引:0
|
作者
Wang, Bingbin [1 ]
Li, Jinglin [1 ]
Hargrove, Levi [2 ,3 ]
Kamavuako, Ernest Nlandu [1 ,4 ]
机构
[1] King's Coll London, Dept Engn, London WC2R 2LS, England
[2] Shirley Ryan Abil, Ctr Bion Med, Chicago, IL 60611 USA
[3] Northwestern Univ, Feinberg Sch Med, Dept Phys Med & Rehabil, Chicago, IL 60611 USA
[4] Univ Kindu, Fac Med, Site Lwama 2, Kindu, DEM REP CONGO
关键词
changes in feature space; electrode shifts; electromyography; limb positions; myoelectric control; pattern recognition; HIGH-DENSITY EMG; ROBUST; FEATURES;
D O I
10.3390/s24154840
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pattern recognition (PR)-based myoelectric control systems can naturally provide multifunctional and intuitive control of upper limb prostheses and restore lost limb function, but understanding their robustness remains an open scientific question. This study investigates how limb positions and electrode shifts-two factors that have been suggested to cause classification deterioration-affect classifiers' performance by quantifying changes in the class distribution using each factor as a class and computing the repeatability and modified separability indices. Ten intact-limb participants took part in the study. Linear discriminant analysis (LDA) was used as the classifier. The results confirmed previous studies that limb positions and electrode shifts deteriorate classification performance (14-21% decrease) with no difference between factors (p > 0.05). When considering limb positions and electrode shifts as classes, we could classify them with an accuracy of 96.13 +/- 1.44% and 65.40 +/- 8.23% for single and all motions, respectively. Testing on five amputees corroborated the above findings. We have demonstrated that each factor introduces changes in the feature space that are statistically new class instances. Thus, the feature space contains two statistically classifiable clusters when the same motion is collected in two different limb positions or electrode shifts. Our results are a step forward in understanding PR schemes' challenges for myoelectric control of prostheses and further validation needs be conducted on more amputee-related datasets.
引用
收藏
页数:15
相关论文
共 29 条
  • [21] Limb Position Tolerant Pattern Recognition for Myoelectric Prosthesis Control with Adaptive Sparse Representations From Extreme Learning
    Betthauser, Joseph L.
    Hunt, Christopher L.
    Osborn, Luke E.
    Masters, Matthew R.
    Levay, Gyorgy
    Kaliki, Rahul R.
    Thakor, Nitish V.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (04) : 770 - 778
  • [22] Analyzing the impact of class transitions on the design of pattern recognition-based myoelectric control schemes
    Raghu, Shriram Tallam Puranam
    MacIsaac, Dawn
    Scheme, Erik
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 71
  • [23] Reducing Classification Accuracy Degradation of Pattern Recognition Based Myoelectric Control caused by Electrode Shift using a High Density Electrode Array
    Boschmann, Alexander
    Platzner, Marco
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 4324 - 4327
  • [24] Semi-supervised adaptation of upper-limb myoelectric pattern recognition prosthesis control through virtual gameplay
    Liu, Andru
    Elwin, Matthew L.
    Wright, Zachary A.
    2023 11TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, NER, 2023,
  • [25] Influence of the Weight Actions of the Hand Prosthesis on the Performance of Pattern Recognition Based Myoelectric Control: Preliminary Study
    Cipriani, Christian
    Sassu, Rossella
    Student, Marco Controzzi
    Carrozza, Maria Chiara
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1620 - 1623
  • [26] Using Serious Games to Measure Upper-Limb Myoelectric Pattern Recognition Prosthesis Control Performance in an At-Home Environment
    Maas, Bart
    Wright, Zack A.
    Lock, Blair A.
    van der Sluis, Corry K.
    Bongers, Raoul M.
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 2024, 36 (03) : 153 - 160
  • [27] Target Achievement Control Test: Evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses
    Simon, Ann M.
    Hargrove, Levi J.
    Lock, Blair A.
    Kuiken, Todd A.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (06): : 619 - 627
  • [28] Real-Time and Offline Performance of Pattern Recognition Myoelectric Control Using a Generic Electrode Grid With Targeted Muscle Reinnervation Patients
    Tkach, Dennis C.
    Young, Aaron J.
    Smith, Lauren H.
    Rouse, Elliott J.
    Hargrove, Levi J.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2014, 22 (04) : 727 - 734
  • [29] Improved High-Density Myoelectric Pattern Recognition Control Against Electrode Shift Using Data Augmentation and Dilated Convolutional Neural Network
    Wu, Le
    Zhang, Xu
    Wang, Kun
    Chen, Xiang
    Chen, Xun
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2020, 28 (12) : 2637 - 2646