The influence on the power consumption for air-conditioning equipment by the ventilation

被引:0
|
作者
Nishitani, Tsuyoshi [1 ]
Ikeda, Kazuki [1 ]
Iwasaki, Yuto [1 ]
Tanaka, Aoi [1 ]
Yukita, Kazuto [1 ]
Nanahara, Toshiya [1 ]
Goto, Tokimasa [2 ]
Mizuno, Katsunori [3 ]
Goto, Yasuyuki [1 ]
机构
[1] Aichi Inst Technol, Dept Elect & Elct Engn, Toyota, Aichi, Japan
[2] Aichi Inst Technol, Dept Dept Business Adm, Toyota, Aichi, Japan
[3] Aichi Inst Technol, Dept Fac Informat Sci, Toyota, Aichi, Japan
关键词
Air conditioning equipment; Energy management system; Power consumption; Ventilation;
D O I
10.1109/ICSMARTGRID55722.2022.9848599
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In recent years, the necessity of energy conservation in the electrical energy field to achieve a zero-carbon society has been established. Energy conservation requires the effective use of electric energy, and energy management systems (EMS) have been attracting attention as one of the technologies for energy conservation. In this study, we have focused on air-conditioning equipment, which consumes a large amount of energy in homes and offices, and have examined the factors that affect their power consumption. We investigated the influence of the presence or absence of ventilation on the power consumption of air-conditioning equipment.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 50 条
  • [31] Test facility for Heating, Ventilation and Air-Conditioning systems
    Yu, B
    van Paassen, DHC
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 951 - 958
  • [32] Testing of Equipment/Retroactive Effects of Air-conditioning Systems
    Vogelsang, Peter
    [J]. WOHLFUHLEN DURCH RAUMLUFTTECHNIK, 2010, 2091 : 143 - 167
  • [33] SAFE DESIGN OF 8290 DUCTED AIR-CONDITIONING EQUIPMENT
    Colbourne, D.
    Arango, A.
    Dickson, E.
    [J]. 13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 46 - 54
  • [34] EVOLUTION OF MATERIALS FOR FANS IN UNITARY AIR-CONDITIONING EQUIPMENT
    KINSWORT.DD
    [J]. ASHRAE JOURNAL, 1971, 13 (07): : 45 - &
  • [35] SOUND RATING OF OUTDOOR UNITARY AIR-CONDITIONING EQUIPMENT
    RAMSEY, RW
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (01): : 118 - &
  • [36] MATERIALS USED IN CONTROLS FOR UNITARY AIR-CONDITIONING EQUIPMENT
    WARREN, DE
    [J]. ASHRAE JOURNAL, 1971, 13 (07): : 44 - &
  • [37] QUIETING THE AIR-CONDITIONING EQUIPMENT FOR A LARGE HOTEL BALLROOM
    GOODFRIEND, LS
    OSTERGAARD, PB
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1960, 32 (07): : 932 - 932
  • [38] THERMAL MODEL FOR EVALUATION OF SUBWAY VENTILATION AND AIR-CONDITIONING
    LASSOW, W
    SCHOCH, KF
    LUSTENADER, EL
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1972, IA 8 (04) : 504 - +
  • [39] INFLUENCE OF RESIDENTIAL VENTILATION MODE ON ENERGY CONSUMPTION OF AIR CONDITIONING AND HEATING
    Yang, Y. X.
    Wang, Z. C.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1079 - 1086
  • [40] VENTILATION STRATEGY AND UNIQUE AIR-CONDITIONING AT INCO LIMITED
    STACHULAK, JS
    [J]. CIM BULLETIN, 1991, 84 (950): : 41 - 45