Transceiver for Ultrasonic Intra-Body Area Networks With Non-Coherent BPSK Detection

被引:1
|
作者
Guedey, Justine [1 ]
Rivet, Francois [1 ]
Lapuyade, Herve [1 ]
Deval, Yann [1 ]
机构
[1] Univ Bordeaux, IMS Lab, F-33405 Talence, France
关键词
Implant; piezoelectric transducer; network; POWER; TRANSMISSION;
D O I
10.1109/TCSII.2024.3357066
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This brief presents a transceiver for an Ultrasonic Intra-Body Area Network (UIBAN) enabling regular monitoring of low data rate bio-signals. The modulation scheme is Binary Phase Shift-Keying (BPSK) because of its superior energy efficiency compared to the other binary modulations. Therefore, a BPSK detector composed of a single D flip-flop is proposed. The carrier frequency is 1 MHz and the bit rate is 7.8125 kbits/s . The integrated circuit (IC) was designed in the 0.35 mu m CMOS technology from AMS. The complete transceiver was measured with 2 2mm diameter ultrasound transducers. The measured Bit Error Rate (BER) was 1.8\times 10(-3) and 1.3 x 10(-2) over a distance of 3.1 cm and 17.5 cm in castor oil, although subjected to many reflections. This is, to the authors' knowledge, the highest measured communication distance with two ultrasonic transducers of a volume lower than 10 mm(3) in an environment similar to that of the human body.
引用
收藏
页码:2976 / 2980
页数:5
相关论文
共 50 条
  • [31] CONSEQUENT DETECTION OF NON-COHERENT SIGNAL
    SHLOMA, AM
    GOLFELD, GB
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1980, 23 (08): : 61 - 64
  • [32] An Intercellular Communication System for Intra-Body Communication Networks
    Rudsari, Hamid Khoshfekr
    Damrath, Martin
    Zoofaghari, Mohammad
    Balasingham, Ilangko
    Veletic, Mladen
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2025, 73 (02) : 817 - 831
  • [33] A Non-coherent BPSK Receiver with Dual Band Filtering for Implantable Biomedical Devices
    Wilkerson, Benjamin P.
    Kang, Jin-Ku
    2012 19TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS (ICECS), 2012, : 697 - 700
  • [34] A unifying perspective of coherent and non-coherent change detection
    Ash, Joshua N.
    ALGORITHMS FOR SYNTHETIC APERTURE RADAR IMAGERY XXI, 2014, 9093
  • [35] Body contour registration by non-coherent interferometry
    Scheiber, C
    Musse, O
    Mallet, Y
    Sirat, G
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 898 - 898
  • [36] Model of a Short Range Non-Coherent IR-UWB Transceiver
    Daoud, Dhoha
    Ghorbel, Mohamed
    Ben Hamida, Ahmed
    2014 1ST INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP 2014), 2014, : 539 - +
  • [37] Neural Network based Transceiver for Non-Coherent OFDM Optical Modulation
    Ibrahim, Asmaa
    Elsheikh, Ahmed
    Abdelsalam, Ahmed M.
    Prat, Josep
    2023 25TH INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATION TECHNOLOGY, ICACT, 2023, : 1424 - 1428
  • [38] Impulse radio based non-coherent UWB transceiver architectures - An example
    Stoica, Lucian
    Rabbachin, Alberto
    Oppermann, Ian
    2006 IEEE INTERNATIONAL CONFERENCE ON ULTRA-WIDEBAND, VOLS 1 AND 2, 2006, : 547 - +
  • [39] Direct-Sequence Ultrasonic Wideband Technology for Intra-Body Communications
    Wang, Qianqian
    Guan, Quansheng
    Ma, Biyun
    Liu, Jiaojiao
    IEEE COMMUNICATIONS LETTERS, 2019, 23 (10) : 1744 - 1747
  • [40] Non-coherent Impulse Radio UWB Receiver for Wireless Body Area Network System
    Im, Junha
    Kim, Jaeseok
    2011 IEEE 54TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2011,