Assessment of Mobility Trajectories Using Wearable Inertial Sensors During Autologous Hematopoietic Cell Transplant

被引:0
|
作者
Skiba, Meghan B. [1 ,2 ,3 ]
El-Gohary, Mahmoud [4 ]
Horak, Fay [4 ,5 ]
Dieckmann, Nathan F. [6 ]
Guidarelli, Carolyn [3 ]
Meyers, Gabrielle [7 ]
Hayes-Lattin, Brandon [7 ]
Winters-Stone, Kerri [3 ,8 ]
机构
[1] Univ Arizona, Coll Nursing, Adv Nursing Practice & Sci Div, Tucson, AZ USA
[2] Univ Arizona, Canc Ctr, Tucson, AZ USA
[3] Oregon Hlth & Sci Univ, Knight Canc Inst, Sch Med, Div Oncol Sci, Portland, OR USA
[4] Clario Inc Co, APDM, Portland, OR USA
[5] Oregon Hlth & Sci Univ, Sch Med, Dept Neurol, Portland, OR USA
[6] Oregon Hlth & Sci Univ, Sch Nursing, Portland, OR USA
[7] Oregon Hlth & Sci Univ, Sch Med, Div Hematol & Med Oncol, Portland, OR USA
[8] Oregon Hlth & Sci Univ, 3181 SW Sam Jackson Pk Rd, Portland, OR 97239 USA
来源
关键词
Disability; Gait analysis; Hematologic neoplasms; Multiple myeloma; Physical functional performance; Postural balance; Rehabilitation; QUALITY-OF-LIFE; 6-MINUTE WALK TEST; INTERNATIONAL CLASSIFICATION; PHYSICAL FUNCTION; CANCER SURVIVORS; RISK-FACTORS; BALANCE; GAIT; PERFORMANCE; VALIDITY;
D O I
10.1016/j.apmr.2024.01.019
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: This study aimed to characterize mobility patterns using wearable inertial sensors and serial assessment across autologous hematopoietic cell transplant (autoHCT) and investigate the relation between mobility and perceived function in patients with hematologic cancer. Design: Prospective longitudinal study. Setting: Hospital adult transplant clinic followed by discharge. Participants: 78 patients with hematological cancer receiving autoHCT. Main Outcome Measures: Mobility was measured across 3 clinical phases (pretransplant, pre-engraftment, and post-engraftment) in using inertial sensors worn during prescribed performance tests in the hospital. Perceived function was assessed using validated provider-reported (Eastern Cooperative Oncology Group [ECOG] Performance Status Scale) and patient-reported [European Organization for Research and Treatment of Cancer Quality of Life Questionnaire [EORTC QLQ-C30]) measures. Trajectories of 5 selected mobility characteristics (turn duration, gait speed, stride time variability, double support time, and heel strike angle) across the clinical phases were also evaluated using piecewise linear mixed-effects models. Results: Using Principal Components Analysis, 4 mobility patterns were identified pretransplant: Gait Limitation, Sagittal Sway, Coronal Sway , and Balance Control. Gait Limitation measured pretransplant was significantly inversely associated with perceived function reported by the provider- ( b = -0.11; 95% CI: -0.19, -0.02) and patient- ( b = -4.85; 95% CI: -7.72, -1.99) post-engraftment in age-adjusted linear regression models. Mobility characteristics demonstrated immediate declines early pre-engraftment with stabilization by late pre-engraftment. Conclusion: Patients with hematological cancer experiencing gait limitations pretransplant are likely to have worse perceived function postengraftment. Mobility declines in early phases post-transplant and may not fully recover, indicating an opportunity for timely rehabilitation referrals. Wearable inertial sensors can be used to identify early mobility problems and patients who may be at risk for future functional decline who may be candidates for early physical rehabilitation. Archives of Physical Medicine and Rehabilitation 2024;105:1106 -15 (c) 2024 by the American Congress of Rehabilitation Medicine.
引用
收藏
页码:1106 / 1115
页数:10
相关论文
共 50 条
  • [21] Trajectories of Fasting Blood Glucose in Autologous Hematopoietic Cell Transplantation
    Hammer, Marilyn J.
    Paul, Steven M.
    Steinberg, Amir
    Eckardt, Patricia
    Barton-Burke, Margaret
    Miaskowski, Christine
    CANCER NURSING, 2019, 42 (04) : 307 - 313
  • [22] Variability Analysis of Therapeutic Movements using Wearable Inertial Sensors
    Irvin Hussein López-Nava
    Bert Arnrich
    Angélica Muñoz-Meléndez
    Arzu Güneysu
    Journal of Medical Systems, 2017, 41
  • [23] TAILORED MOBILIZATION IN AUTOLOGOUS HEMATOPOIETIC STEM CELL TRANSPLANT
    Santos, Olga
    Campanico, Soraia
    Branco, Isabel
    Brilhante, Dialina
    BONE MARROW TRANSPLANTATION, 2023, 58 (SUPP1) : 611 - 611
  • [24] Load Position and Weight Classification during Carrying Gait Using Wearable Inertial and Electromyographic Sensors
    Gorsic, Maja
    Dai, Boyi
    Novak, Domen
    SENSORS, 2020, 20 (17) : 1 - 14
  • [25] A convenient approach for knee kinematics assessment using wearable inertial sensors during home-based rehabilitation: Validation with an optoelectronic system
    El Fezazi, Mohamed
    Achmamad, Abdelouahad
    Jbari, Atman
    Jilbab, Abdelilah
    SCIENTIFIC AFRICAN, 2023, 20
  • [26] Teager Energy assessment of tremor severity in clinical application of wearable inertial sensors
    Hanson, Mark A.
    Powell, Harry C.
    Frysinger, Robert C.
    Huss, Diane S.
    Elias, W. Jeffrey
    Lach, John
    2007 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2007, : 136 - +
  • [27] Usability study of wearable inertial sensors for exergames (WISE) for movement assessment and exercise
    Rajkumar, Ashwin
    Vulpi, Fabio
    Bethi, Satish Reddy
    Raghavan, Preeti
    Kapila, Vikram
    MHEALTH, 2021, 7 (01)
  • [28] Assessment of the pivot shift using inertial sensors
    Zaffagnini S.
    Signorelli C.
    Grassi A.
    Yue H.
    Raggi F.
    Urrizola F.
    Bonanzinga T.
    Marcacci M.
    Current Reviews in Musculoskeletal Medicine, 2016, 9 (2) : 160 - 163
  • [29] Using Wearable Inertial Sensors to Monitor Effectiveness of Different Types of Customized Orthoses during CrossFit® Training
    Brognara, Lorenzo
    Mazzotti, Antonio
    Rossi, Federica
    Lamia, Francesca
    Artioli, Elena
    Faldini, Cesare
    Traina, Francesco
    SENSORS, 2023, 23 (03)
  • [30] Validation of Foot-Strike Assessment Using Wearable Sensors During Running
    DeJong, Alexandra F.
    Hertel, Jay
    JOURNAL OF ATHLETIC TRAINING, 2020, 55 (12) : 1307 - 1310