Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

被引:0
|
作者
Mathews, Ashwin Joseph [1 ]
Krishnan, Easwaran N. [2 ]
Joseph, Albin [1 ]
Annadurai, Gurubalan [3 ]
Fauchoux, Melanie T. [1 ]
Simonson, Carey J. [1 ]
机构
[1] Univ Saskatchewan, Dept Mech Engn, Saskatoon, SK S7N 5A9, Canada
[2] Oak Ridge Natl Lab, Bldg & Transportat Sci Div, Oak Ridge, TN 37830 USA
[3] Indian Inst Technol, Dept Energy Sci & Engn, Mumbai 400076, India
基金
加拿大自然科学与工程研究理事会;
关键词
Membrane-based air-to-air energy exchanger; Contaminant transfer; Exhaust air transfer ratio; Membranes; Indoor air quality; Gaseous contaminants; VOCs; WATER-VAPOR; GAS; PERMEATION; VENTILATION; TRANSPORT; SORPTION; VOLUME;
D O I
10.1016/j.enbuild.2024.114428
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Membrane-based air-to-air energy exchangers (M-AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and airconditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (epsilon-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Validation of extrapolation of test performance for air-to-air rotary energy exchangers (ASHRAE RP-1799)
    Wang, Weimin
    Alhariry, Alaa Jamal
    Gowri, Krishnan
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (01) : 34 - 48
  • [32] Air-to-air enthalpy exchangers: Membrane modification using metal-organic frameworks, characterisation and performance assessment
    Albdoor, Ahmed K.
    Ma, Zhenjun
    Cooper, Paul
    Al-Ghazzawi, Fatimah
    Liu, Jingjing
    Richardson, Christopher
    Wagner, Pawel
    Journal of Cleaner Production, 2021, 293
  • [33] An analytical solution for heat mass transfer in a hollow fiber membrane based air-to-air heat mass exchanger
    Zhang, Li-Zhi
    JOURNAL OF MEMBRANE SCIENCE, 2010, 360 (1-2) : 217 - 225
  • [34] Comparison of the Heat Transfer Efficiency of Selected Counterflow Air-to-Air Heat Exchangers Under Unbalanced Flow Conditions
    Kaminski, Kazimierz
    Znaczko, Pawel
    Kardas-Cinal, Ewa
    Chamier-Gliszczynski, Norbert
    Koscielny, Krzysztof
    Cur, Krzysztof
    ENERGIES, 2025, 18 (01)
  • [35] MEMBRANE-BASED COMPRESSED-AIR DRYER
    HAGGIN, J
    CHEMICAL & ENGINEERING NEWS, 1988, 66 (29) : 35 - 35
  • [36] Membrane-Based Direct Air Capture: A Review
    Yang, Seong Baek
    Im, Kwang-Seop
    Nikita, Km
    Nam, Sang Yong
    APPLIED CHEMISTRY FOR ENGINEERING, 2024, 35 (02): : 85 - 95
  • [37] A testing and HVAC design methodology for air-to-air heat pipe heat exchangers
    Guo, PB
    Ciepliski, DL
    Besant, RW
    HVAC&R RESEARCH, 1998, 4 (01): : 3 - 26
  • [38] Heat and mass transfer modeling of an energy efficient Hybrid Membrane-Based Air Conditioning System for humid climates
    Abdollahi, F.
    Hashemifard, S. A.
    Khosravi, A.
    Matsuura, T.
    JOURNAL OF MEMBRANE SCIENCE, 2021, 625
  • [39] Performance Deteriorations from Flow Maldistribution in Air-to-Air Heat Exchangers: A Parallel-Plates Membrane Core Case
    Zhang, Li-Zhi
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2009, 56 (09) : 746 - 763
  • [40] ASSESSMENT OF THE PROBABILITY OF FAILURES OF AIR-TO-AIR HEAT EXCHANGERS DURING OPERATION OF AVIATION SEA-BASED AIR CONDITIONING SYSTEMS
    Galimov, Almir R.
    Merkulov, Vladislav, I
    Nikolaevich, Pokusaev M.
    Tishchenko, Igor, V
    MARINE INTELLECTUAL TECHNOLOGIES, 2018, 2 (04): : 155 - 160