Air Flow in Sanitary Sewer Laterals

被引:2
|
作者
Qian, Yu [1 ]
Shao, Weiyun [2 ]
Steffler, Peter M. [2 ]
Zhu, David Z. [1 ,2 ]
机构
[1] Ningbo Univ, Sch Civil & Environm Engn & Geog Sci, Ningbo 315211, Zhejiang, Peoples R China
[2] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 1H9, Canada
基金
国家重点研发计划; 加拿大自然科学与工程研究理事会;
关键词
Air pressure; Air-water drag; Sanitary sewer; Sewer air flow; Sewer laterals; Wastewater drag; WASTE-WATER DRAG; VENTILATION MODEL; CONCRETE; DYNAMICS;
D O I
10.1061/JHEND8.HYENG-13857
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air in the headspace of sewer laterals can be driven by the flowing sewage as well as air pressure. In this study, the openings on manholes for air flow are approximated as a thin continuous slot at the laterals. In this way, the governing equations can be solved analytically for infinitely long laterals without water flow. For cases with water flow, a numerical solution is developed. It is found that the air flow pattern in a long lateral can be categorized into three zones. The zone closest to the trunk is defined as the "zone of influence," where the air flow in the lateral is dominated by air pressure, and the air pressure and air velocity decay exponentially in the lateral. The second zone is named as "zone of equilibrium" where the air pressure gradient is zero and the air flow is only driven by the drag of water and can be calculated analytically. The air flow zone farthest from the trunk is defined as the "zone of induction" where the air is inducted into the system for mass balance in the system. An explicit fitting expression on the air velocity and water velocity in a long lateral is provided. A graphic solution for air velocity and zone of influence is also developed for a quick estimation on the air movement in sewer laterals.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] AN EVALUATION OF PROBLEMS OF SANITARY SEWER SYSTEM DESIGN
    GEYER, JC
    LENTZ, JJ
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1966, 38 (07): : 1138 - &
  • [22] SANITARY SEWER EXTENSION BUILT ABOVE GROUND
    EASLEY, RA
    CIVIL ENGINEERING, 1971, 41 (04): : 66 - &
  • [23] DESIGNING FOR REMOVAL OF SANITARY SEWER CROSS CONNECTIONS
    HOLLENBECK, AJ
    WATER-ENGINEERING & MANAGEMENT, 1984, 131 (04): : 29 - 31
  • [24] Monitoring sewage networks for sanitary sewer overflows
    Abu Sier, D
    Lansey, K
    CIVIL ENGINEERING AND ENVIRONMENTAL SYSTEMS, 2005, 22 (02) : 123 - 132
  • [25] Integrating sanitary sewer system automation with GIS
    Wang, MH
    CONFERENCE XXII - GEOSPATIAL INFORMATION & TECHNOLOGY ASSOCIATION, PROCEEDINGS, 1999, : 199 - 206
  • [26] POLYETHYLENE PIPE SLIPPED INTO DEFECTIVE SANITARY SEWER
    HARLAN, TS
    ALLMAN, WB
    CIVIL ENGINEERING, 1973, 43 (06): : 78 - 81
  • [27] Innovations in pipe linings for sanitary sewer rehabilitation
    Abraham, DM
    Gillani, SA
    Gokhale, S
    MATERIALS AND CONSTRUCTION: EXPLORING THE CONNECTION, 1999, : 484 - 491
  • [28] SANITARY SEWER BEDDING SCORED AS UNDERDRAIN CONDUIT
    MCFALL, RL
    CIVIL ENGINEERING, 1972, 42 (05): : 51 - &
  • [29] Sanitary district brings in the sleeves to enlarge sewer
    不详
    CIVIL ENGINEERING, 1996, 66 (08): : 78 - 78
  • [30] USE OF COMPUTERS IN DESIGN OF SANITARY SEWER SYSTEMS
    DECICCO, PR
    SOEHNGEN, HF
    TAKAGI, J
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1968, 40 (2P1): : 269 - &