摘要
The increasing interest in solar energy has led to the development of various connection types designed to enhance the efficiency of photovoltaic (PV) systems under different environmental conditions. Addressing the challenges associated with these connection types is crucial for improving the reliability of solar energy utilization. Accordingly, the significance of electrical faults in PV systems with different array configurations has grown. This study aims to comprehensively evaluate Line-to-Different Line (LDL), Line-to-Line (LL), and Line-to-Neutral (LN) electrical fault types using the Series-Parallel (SP), Total-Cross-Tie (TCT), Bridge- Link (BL), Honey-Comb (HC), SP-TCT, BL-TCT, BL-HC, and HC-TCT PV array connection types on the TMS320F28338 DSP kit based Processor-in-Loop (PIL) platform. To do this, The Reliability Index (RI) and Efficiency Index (EI) are defined and calculated for all possible fault types based on the array's fault current and generated power. Additionally, the current paths of the system under different fault conditions for eight configuration types are formalized. With this, the electrical fault states of a PV array in any dimension can be easily analyzed with the proposed method, and it will also facilitate the electrical fault analysis of a new PV configuration to be proposed in the future. The results of this work indicate that among the eight configurations, the TCT achieves the highest RI value of 3.59 under all electrical fault types. In contrast, the SP configuration has the lowest RI of 1.28. Conversely, the SP array configuration shows a significantly higher average EI of 81.86%, while the TCT configuration has the lowest EI of 56.56%. These indicate that the TCT configuration is the most reliable under electrical faults; however, the SP configuration is the most efficient. In addition, among the three electrical fault types, the LN fault causes more deterioration in the RI and EI across almost all connection types.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] PV system influence on electrical power quality in point of connection
    Hejtmankova, Pavla
    Dvorsky, Emil
    Skorpil, Jan
    Scerba, Eduard
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 1657 - 1660
  • [22] In connection with the analysis of anthropologic types
    Stolyhwo, K
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1924, 90 : 1194 - 1195
  • [23] BASICITY OF BICYCLIC HYDRAZIDES WITH VARIOUS TYPES OF RING CONNECTION
    YAKHONTOV, LN
    VAISMAN, MN
    KOMAROVA, NA
    PORTNOV, MA
    MIKHLINA, EE
    KHIMIYA GETEROTSIKLICHESKIKH SOEDINENII, 1972, (02): : 220 - +
  • [24] Analysis of a Partially Shaded PV Array Considering Different Module Connection Schemes and Effects of Bypass Diodes
    Wang, Yaw-Juen
    Lin, Shu-Syuan
    2011 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON POWER AND ENERGY SYSTEMS: ISSUES & PROSPECTS FOR ASIA (ICUE), 2011,
  • [25] Accurate Fault Diagnosis Technique for Series Parallel PV Array
    Ryad, Ahmed K.
    Atallah, Ahmed M.
    Zekry, Abdelhalim
    2019 21ST INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON 2019), 2019, : 53 - 58
  • [26] PV Array Fault Detection using Radial Basis Networks
    Pedersen, Emma
    Rao, Sunil
    Katoch, Sameeksha
    Jaskie, Kristen
    Spanias, Andreas
    Tepedelenlioglu, Cihan
    Kyriakides, Elias
    2019 10TH INTERNATIONAL CONFERENCE ON INFORMATION, INTELLIGENCE, SYSTEMS AND APPLICATIONS (IISA), 2019, : 306 - 309
  • [27] PV Array Fault Detection Based on Deep Neural Network
    Gao, Wei
    2021 13TH ANNUAL IEEE GREEN TECHNOLOGIES CONFERENCE GREENTECH 2021, 2021, : 42 - 47
  • [28] The Fault Analysis of PV Cable Fault in DC Microgrids
    Zhang, Zhiming
    Chen, Qing
    Xie, Ranran
    Sun, Kongming
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (01) : 486 - 496
  • [29] Reliability Assessment of a Fault-Tolerant PV Multistring Inverter
    Renaudineau, Hugues
    Paradell-Sola, Pol
    Trilla, Liuis
    Filba-Martinez, Alber
    Cardoner, David
    Luis Dominguez-Garcia, Jose
    ENERGIES, 2020, 13 (24)
  • [30] Reliability assessment and optimization of main electrical connection of substation
    Xu, Xiaoning
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (12): : 441 - 446