Electrical fault and reliability analysis of various PV array connection types

被引:0
|
作者
Avci, Emre [1 ]
机构
[1] Duzce Univ, Dept Elect & Elect Engn, TR-81620 Duzce, Turkiye
关键词
Connection type; Electrical fault; Panel configuration; Photovoltaic (PV); Solar energy; PERFORMANCE ENHANCEMENT; DIAGNOSIS; CONFIGURATIONS; SYSTEMS;
D O I
10.1016/j.jestch.2024.101774
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The increasing interest in solar energy has led to the development of various connection types designed to enhance the efficiency of photovoltaic (PV) systems under different environmental conditions. Addressing the challenges associated with these connection types is crucial for improving the reliability of solar energy utilization. Accordingly, the significance of electrical faults in PV systems with different array configurations has grown. This study aims to comprehensively evaluate Line-to-Different Line (LDL), Line-to-Line (LL), and Line-to-Neutral (LN) electrical fault types using the Series-Parallel (SP), Total-Cross-Tie (TCT), Bridge- Link (BL), Honey-Comb (HC), SP-TCT, BL-TCT, BL-HC, and HC-TCT PV array connection types on the TMS320F28338 DSP kit based Processor-in-Loop (PIL) platform. To do this, The Reliability Index (RI) and Efficiency Index (EI) are defined and calculated for all possible fault types based on the array's fault current and generated power. Additionally, the current paths of the system under different fault conditions for eight configuration types are formalized. With this, the electrical fault states of a PV array in any dimension can be easily analyzed with the proposed method, and it will also facilitate the electrical fault analysis of a new PV configuration to be proposed in the future. The results of this work indicate that among the eight configurations, the TCT achieves the highest RI value of 3.59 under all electrical fault types. In contrast, the SP configuration has the lowest RI of 1.28. Conversely, the SP array configuration shows a significantly higher average EI of 81.86%, while the TCT configuration has the lowest EI of 56.56%. These indicate that the TCT configuration is the most reliable under electrical faults; however, the SP configuration is the most efficient. In addition, among the three electrical fault types, the LN fault causes more deterioration in the RI and EI across almost all connection types.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Power Enhancement of Partial Shaded PV Array by Optimizing the Electrical Connection of Module
    Wang, Mengyao
    INTERNATIONAL CONFERENCE ON ENGINEERING TECHNOLOGY AND APPLICATION (ICETA 2015), 2015, 22
  • [2] Traction Substation Electrical Main Connection Reliability Analysis
    Ding, Xuecheng
    He, Zhengyou
    Yu, Min
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 7293 - +
  • [3] Reliability analysis of the solar array based on Fault Tree Analysis
    Wu Jianing
    Yan Shaoze
    9TH INTERNATIONAL CONFERENCE ON DAMAGE ASSESSMENT OF STRUCTURES (DAMAS 2011), 2011, 305
  • [4] Reliability analysis of PV array or modules with supercapacitor based measurement techniques
    Majumdar, Debashis
    Pal, Sudipta Basu
    Ganguly, Rajiv
    Das Bhattacharya, Konika
    Chanda, Chandan Kumar
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2024, 30 (09): : 1191 - 1200
  • [5] The Impact of PV array Inclination on the PV Inverter Reliability and Lifetime
    Bouguerra, Sara
    Agroui, Kamel
    Yaiche, Mohamed Redha
    Sangwongwanich, Ariya
    Blaabjerg, Frede
    2020 IEEE 9TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC2020-ECCE ASIA), 2020, : 617 - 622
  • [6] Impacts of PV Array Sizing on PV Inverter Lifetime and Reliability
    Sangwongwanich, Ariya
    Yang, Yongheng
    Sera, Dezso
    Blaabjerg, Frede
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 3830 - 3837
  • [7] PV array fault DiagnosticTechnique for BIPV systems
    Hachana, Oussama
    Tina, Giuseppe Marco
    Hemsas, Kamel Eddine
    ENERGY AND BUILDINGS, 2016, 126 : 263 - 274
  • [8] Reliability Analysis on Main Connection Taking Fault Clearance and Switching Operation into Account
    Liu, Wenwen
    Wang, Yong
    Ding, Ying
    2016 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2016, : 200 - 204
  • [9] Modeling of Electrical Characteristics of Various PV Panels
    Milenov, Valentin
    Zarkov, Zahari
    Demirkov, Boris
    Bachev, Ivan
    2019 16TH CONFERENCE ON ELECTRICAL MACHINES, DRIVES AND POWER SYSTEMS (ELMA), 2019,
  • [10] PV array Fault Classification based on Machine Learning
    Nguyen Quoc Minh
    Do Thi Dieu Mai
    Ha Huy Phuc Nguyen
    2022 11TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND INFORMATION SCIENCES (ICCAIS), 2022, : 322 - 326