Experimental and numerical investigations of seismic performance of stepped beam-column joints with different connection forms

被引:1
|
作者
Cheng, Xin [1 ,2 ]
Li, Yun [1 ]
An, Yi [1 ,2 ]
Liu, Jianfei [1 ]
Zhang, Ruibin [3 ]
Liao, Fangfang [4 ]
机构
[1] Taiyuan Univ Technol, Dept Civil Engn, Taiyuan 030024, Peoples R China
[2] Taiyuan Univ Technol, Shanxi Key Lab Civil Engn Disaster Prevent & Contr, Taiyuan 030024, Peoples R China
[3] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[4] Changan Univ, Sch Civil Engn, Xian 710061, Peoples R China
来源
基金
中国博士后科学基金;
关键词
Beam-column joint; Connection forms; Flush beam flanges; Full-scale test; Seismic performance; STEEL; BEHAVIOR; DESIGN;
D O I
10.1016/j.jobe.2024.109543
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The seismic resilience of prefabricated steel structures significantly depends on the design and construction of beam-column joints. To address the challenges related to the installation of prefabricated wall panels and overall system assembly, this study introduces a novel stepped beam-column joint. The effectiveness of different connection configurations on the seismic behavior of the joints was investigated. A series of cyclic tests were conducted on four joint specimens with different configurations, and their failure mechanisms, hysteretic curves, skeleton curves, stiffness degradation, load-bearing capacity, and energy dissipation capacity, were revealed. The experimental results showed that the stepped joint configuration offers favourable seismic performance, with notable asymmetry observed in the response patterns under positive and negative loading directions. Reducing the height of the stepped segment or the thickness of the end plate adversely affected the seismic performance, leading to early bolt failure. Consequently, a detailed finite element model of the stepped joint was developed and the model demonstrated satisfactory agreement with the experimental results. Furthermore, a parametric analysis focusing on variations in stepped segment ' s height was conducted, providing insights into optimization of the load-bearing capacity of the stepped joint. The difference in the performance between the stepped joints and traditional flush end plate joints is also highlighted.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Experimental study on the seismic behavior of an innovative stepped beam-column joint
    Li, Yun
    Cheng, Xin
    An, Yi
    Zhang, Ruibin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 214
  • [22] Experimental study on the seismic behavior of an innovative stepped beam-column joint
    Li, Yun
    Cheng, Xin
    An, Yi
    Zhang, Ruibin
    Journal of Constructional Steel Research, 2024, 214
  • [23] Experimental Study on Seismic Performance of Precast Pretensioned Prestressed Concrete Beam-Column Interior Joints Using UHPC for Connection
    Xiong, Xueyu
    Xie, Yifan
    Yao, Gangfeng
    Liu, Ju
    Yan, Laizhang
    He, Liang
    MATERIALS, 2022, 15 (16)
  • [24] Seismic performance of SMA-prestressed self-centering beam-column joints: Experimental and numerical study
    Feng, Yutao
    Li, Weibin
    Journal of Constructional Steel Research, 2025, 226
  • [25] Seismic Performance of Beam-Column Connection According to Load Velocity
    Oh, Sanghoon
    Park, Jaehan
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, STESSA 2024 - VOL 1, 2024, 519 : 337 - 349
  • [26] Experimental and numerical research on seismic behavior of end-plate connection beam-column joints considering concrete floor effect
    Lu, Shengcan
    Zhang, Jiong
    Wang, Minrong
    Chen, Huiquan
    STRUCTURES, 2024, 65
  • [27] Experiment of seismic performance of UHTCC reinforced beam-column joints
    Su, Jun
    Li, Wei
    Zhang, Jin
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2015, 43 (09): : 110 - 113
  • [28] Experimental Investigation of Seismic Performance of a Hybrid Beam-Column Connection in a Precast Concrete Frame
    Chen, Weihong
    Xie, Yujun
    Guo, Xiaohui
    Li, Dong
    BUILDINGS, 2022, 12 (06)
  • [29] Seismic performance of RC interior wide beam-column joints
    Jiang, Qing
    Xuan, Dianchun
    Chong, Xun
    Shen, Jie
    Fan, Yonglong
    Su, Wenji
    STRUCTURES, 2023, 48 : 373 - 389
  • [30] Seismic performance of RC exterior wide beam-column joints
    Jiang, Qing
    Su, Wenji
    Feng, Yulong
    Shen, Jie
    Fan, Yonglong
    Xuan, Dianchun
    STRUCTURAL CONCRETE, 2024, : 5037 - 5055