Functional and anatomical results of subthreshold micropulse laser as rescue treatment for central serous chorioretinopathy after verteporfin shortage

被引:2
|
作者
Oribio-Quinto, Carlos [1 ]
Alarcon-Garcia, Antonio Domingo [1 ]
Enriquez-Fuentes, Jacobo [1 ]
Burgos-Blasco, Barbara [1 ]
Fernandez-Vigo, Jose Ignacio [1 ,2 ]
机构
[1] Fdn Invest Biomed Hosp Clin San Carlos IdISCC, Dept Ophthalmol, Madrid, Spain
[2] Ctr Int Oftalmol Avanzada, Madrid, Spain
关键词
Central serous chorioretinopathy; Subthreshold micropulse laser; Photodynamic therapy; Verteporfin; Rescue therapy; PHOTODYNAMIC THERAPY; INTRAVITREAL INJECTIONS; HALF-FLUENCE; PHOTOCOAGULATION;
D O I
10.1016/j.pdpdt.2024.104295
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To evaluate the anatomical and functional outcomes of high-density subthreshold micropulse laser (HSML) treatment in a cohort of patients diagnosed with chronic central serous chorioretinopathy (CSCR) whose treatment with photodynamic therapy (PDT) was delayed due to the worldwide shortage of verteporfin. Methods: Prospective interventional study which included 42 eyes of 40 patients diagnosed with chronic CSCR and on the waiting list for PDT who received rescue therapy with HSML using the Navilas (R) System device (OD-OS GmBH, Teltwo, Germany). Best corrected visual acuity (BCVA), subretinal fluid (SRF), and subfoveal choroidal thickness (SFCT) were measured at inclusion and during the follow-up visits at 2, 4, and 6 months. Results: The mean waiting time from the indication of PDT until treatment with HSML was 14.6 +/- 9.7 months (range 5-21). There were no differences in the pre-treatment BCVA compared with the 6-month follow-up visit (67 +/- 16.7 letters and 67.5 +/- 8.2 letters respectively, p = 0.136). However, there was a significant decrease in the mean SFCT of -39.6 +/- 37.1 mu m (p = 0.030). Additionally, there was a decrease in SRF height between the pre-treatment measure (123.0 +/- 49.8 mu m) and the 2, 4, and 6-month follow-up visits after HSML of -58.5 +/- 68.2 mu m, -53.2 +/- 76.3 mu m, and -65.4 +/- 53.6 mu m respectively (p < 0.001). A complete resolution of the SRF was observed in 16/42 eyes (38.1 %) and a reduction of the SRF height in 85.7 % of the overall cohort was observed after HSML treatment. Conclusion: A significant anatomical improvement in SRF and a decrease in SFCT were observed in patients with CSCR who were previously waiting for PDT and were rescued by HSML. However, the rate of complete SRF resolution was low.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] 577 nm subthreshold micropulse laser treatment for acute central serous chorioretinopathy: a comparative study
    Long, He
    Liu, Maoxiong
    Hu, Qinghua
    Li, Xin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [22] 577 nm subthreshold micropulse laser treatment for acute central serous chorioretinopathy: a comparative study
    He Long
    Maoxiong Liu
    Qinghua Hu
    Xin Li
    BMC Ophthalmology, 22
  • [23] Morphological parameters predicting subthreshold micropulse laser effectiveness in central serous chorioretinopathy
    Kiraly, Peter
    Smrekar, Jaka
    Mekjavic, Polona Jaki
    LASERS IN MEDICAL SCIENCE, 2022, 37 (08) : 3129 - 3136
  • [24] Morphological parameters predicting subthreshold micropulse laser effectiveness in central serous chorioretinopathy
    Peter Kiraly
    Jaka Smrekar
    Polona Jaki Mekjavić
    Lasers in Medical Science, 2022, 37 : 3129 - 3136
  • [25] Subthreshold diode micropulse laser versus observation in acute central serous chorioretinopathy
    Arora, Supriya
    Sridharan, Preethi
    Arora, Tarun
    Chhabra, Mohit
    Ghosh, Basudeb
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (01) : 79 - 85
  • [26] Crossover to PDT after the unsuccessful micropulse laser treatment of central serous chorioretinopathy
    Gawecki, Maciej
    Kicinski, Krzysztof
    Grzybowski, Andrzej
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2024, 4 (01): : 32 - 38
  • [27] Evaluation of changes in macular structures after subthreshold micropulse laser therapy on chronic central serous chorioretinopathy
    Liu, Lijun
    Xu, Qian
    Song, Xian
    Zhao, Yuqing
    Zhang, Yu
    Qu, Yi
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [28] Comparison of two laser power levels in the subthreshold micropulse yellow laser treatment of acute central serous chorioretinopathy
    Qin, Liru
    Li, Daming
    Zhou, Yuzhe
    Zhang, Han
    Zhang, Guisen
    Zhang, Xiurong
    Shi, Wei
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 49
  • [29] Nonvisible subthreshold micropulse diode laser (810 nm) treatment of central serous chorioretinopathy: A pilot study
    Lanzetta, P.
    Furlan, F.
    Morgante, L.
    Veritti, D.
    Bandello, F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (06) : 934 - 940
  • [30] Predictive factors of treatment response for navigated yellow subthreshold micropulse laser in chronic central serous chorioretinopathy
    Iovino, Claudio
    Iodice, Clemente Maria
    Damiano, Luciana
    Pisani, Danila
    Rossi, Settimio
    Simonelli, Francesca
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)