摘要
Measurements of neutron ambient dose equivalent rates are challenging because there are no perfect instruments that cover the entire 9 orders of magnitude neutron energy range (thermal to 20 MeV). Hence quantifying performance requirements with the international standard IEC 61005 for neutron ambient dose equivalent rate meters presents unique challenges. This paper discusses the requirements of this standard, which have been refined and improved over the last 20 years. Examples of type testing results for the constancy of ambient dose rate response, variation of the response due to neutron energy, response time, and various environmental disturbances are examined. IEC 61005 provides manufacturers with internationally acceptable requirements and provides consistent test methods for compliance with stated performance requirements.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Assessment of ambient dose equivalent rate distribution patterns in a forested-rugged terrain using field-measured and modeled dose equivalent rates
    Yasumiishi, Misa
    Masoudi, Pedram
    Nishimura, Taku
    Ochi, Kotaro
    Ye, Xiang
    Aldstadt, Jared
    Komissarov, Mikhail
    [J]. RADIATION MEASUREMENTS, 2023, 168
  • [42] Neutron spectrum unfolding based on generalized regression neural networks for neutron fluence and neutron ambient dose equivalent estimations
    Wang, Jie
    Guo, Zhirong
    Chen, Xianglei
    Zhou, Yulin
    [J]. APPLIED RADIATION AND ISOTOPES, 2019, 154
  • [43] Neutron dose equivalent rate in heavy ion accelerator target area
    Li, Guisheng
    Zhang, Tianmei
    Li, Zongwei
    Su, Youwu
    Zhang, Shumin
    [J]. He Jishu/Nuclear Techniques, 1999, 22 (12): : 771 - 774
  • [44] Measurement of neutron ambient dose equivalent in passive carbon-ion and proton radiotherapies
    Yonai, Shunsuke
    Matsufuji, Naruhiro
    Kanai, Tatsuaki
    Matsui, Yuki
    Matsushita, Kaoru
    Yamashita, Haruo
    Numano, Masumi
    Sakae, Takeji
    Terunuma, Toshiyuki
    Nishio, Teiji
    Kohno, Ryosuke
    Akagi, Takashi
    [J]. MEDICAL PHYSICS, 2008, 35 (11) : 4782 - 4792
  • [45] Use of prompt gamma emissions from polyethylene to estimate neutron ambient dose equivalent
    Priyada, P.
    Sarkar, P. K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 785 : 135 - 142
  • [46] Monte Carlo study of neutron-ambient dose equivalent to patient in treatment room
    Mohammadi, A.
    Afarideh, H.
    Davani, F. Abbasi
    Ghergherehchi, M.
    Arbabi, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 118 : 140 - 148
  • [47] EVALUATION OF NEUTRON AMBIENT DOSE EQUIVALENT IN INTENSITY-MODULATED COMPOSITE PARTICLE THERAPY
    Matsumoto, Shinnosuke
    Yonai, Shunsuke
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 193 (02) : 90 - 95
  • [48] Design of Three-detector Neutron Ambient Dose Equivalent and Spectrum Monitor Instrument
    Zhou Y.
    Zeng L.
    Ren C.
    Sun G.
    Liu H.
    Wang J.
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2021, 55 : 143 - 150
  • [49] Neural networksfor predicting neutron ambient dose equivalent measured by means of Bonner spheres
    Braga, CC
    Dias, MS
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1580 - 1583
  • [50] EVALUATION OF NEUTRON AMBIENT DOSE EQUIVALENT IN CARBON-ION RADIOTHERAPY WITH ENERGY SCANNING
    Matsumoto, Shinnosuke
    Yonai, Shunsuke
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (03) : 310 - 318