Case study on combined heat and water system for district heating in Beijing through recovery of industrial waste heat in Tangshan

被引:2
|
作者
Yang, Xiaolin [1 ]
Kong, Ying [1 ]
Zhou, Yu [2 ]
Liu, Dawei [2 ]
Xia, Jianjun [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing, Peoples R China
[2] Shougang Environm Ind Co Ltd, Beijing, Peoples R China
关键词
Combined heat and water system; District heating; Desalination; Industrial waste heat; Long-distance transportation; Seasonal thermal storage;
D O I
10.1016/j.energy.2024.131316
中图分类号
O414.1 [热力学];
学科分类号
摘要
With the proposal of China ' s dual -carbon goal, the recovery of industrial waste heat (IWH) for district heating has gained increasing attention. Recently, some scholars have proposed that combined heat and water (CHW) systems are more economical compared with separate heat and water supplies. Beijing lacks desalinated water (DW) and clean low -carbon heat, whereas Tangshan in Hebei Province is rich in IWH. By combining CHW with seasonal thermal energy storage, a case of long-distance transport of hot DW from Tangshan to Beijing was planned, and the costs, energy consumption, and feasibility were analyzed. As a result, under the optimal heat source temperature and effect number of 70 degrees C and 10 for seawater desalination, the heat from various IWH sources of the three costal steel plants is recovered maximally to produce about 35000 t/h of 95 degrees C DW. Then, the hot DW is transported to Beijing with a long-distance heat loss ratio controlled below 3 %. Annually, 271.2 million tons of DW and 91.5 million GJ of heat is supplied. The introduction of IWH can save 2.68 billion Nm 3 of natural gas per year and the discounted payback period is about 10 years, which has obvious energy -saving, environmental, and economic benefits.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] An Integrated Heating System for Large Buildings with Heat Pumps and Waste Heat Recovery.
    Kalischer, P.
    [J]. TEW Technische Berichte, 1975, 44 (04): : 79 - 86
  • [42] Application of heat pump water heating system with heat recovery in ammonia refrigeration system
    Huang, Tao
    Yuan, Dongli
    [J]. ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 670 - 673
  • [43] Dynamic Simulation of Heat Losses in a District Heating System: A Case Study in Wales
    Li, Yu
    Rezgui, Yacine
    Zhu, Hanxing
    [J]. 2016 THE 4TH IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE), 2016, : 273 - 277
  • [44] Optimal utilisation of heat demand in district heating system-A case study
    Gebremedhin, Alemayehu
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 30 : 230 - 236
  • [45] A WASTE HEAT DISTRICT HEATING-SYSTEM WITH SEASONAL-VARIATIONS
    MAHINI, RT
    SCHROCK, VE
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 35 - 36
  • [46] An analytical framework for assessing the integration of the waste heat into a district heating system: Case of the city of Riga
    Ziemele, Jelena
    Dace, Elina
    [J]. ENERGY, 2022, 254
  • [47] Optimal Seasonal Heat Storage in a District Heating System with Waste Incineration
    Penttinen, Petri
    Vimpari, Jussi
    Junnila, Seppo
    [J]. ENERGIES, 2021, 14 (12)
  • [48] Combined energetic, economic and climate change assessment of heat pumps for industrial waste heat recovery
    Jovet, Yoann
    Lefevre, Frederic
    Laurent, Alexis
    Clausse, Marc
    [J]. APPLIED ENERGY, 2022, 313
  • [49] New low temperature industrial waste heat district heating system based on natural gas fired boilers with absorption heat exchangers
    Sun, Fangtian
    Cheng, Lijiao
    Fu, Lin
    Gao, Junwei
    [J]. APPLIED THERMAL ENGINEERING, 2017, 125 : 1437 - 1445
  • [50] INDUSTRIAL-WASTE HEAT-RECOVERY - A CASE IN POINT
    TRUEDSSON, GR
    [J]. ENERGY ENGINEERING, 1980, 77 (02) : 14 - 16