Implementation of a real-time fNIRS signal quality assessment

被引:0
|
作者
Ferdinando, Hany [1 ]
Ilvesmaki, Martti [1 ]
Tone, Patricia-Elena [1 ]
Rahayu, Triana [1 ]
Moradi, Sadegh [2 ]
Myllyla, Teemu [1 ,2 ]
机构
[1] Univ Oulu, Fac Med, Res Unit Hlth Sci & Technol, Oulu, Finland
[2] Univ Oulu, Optoelet & Measurement Tech Res Unit, Oulu, Finland
关键词
fNIRS; signal quality index; power ratio; skewness; kurtosis; INDEX;
D O I
10.1117/12.3005688
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Signal quality is crucial in any signal analysis. Typically, the reason for bad signal quality is inappropriate sensor placement which is also highly dependent on the measurement location. It is usually quite easy to get a good optical signal from finger, but not from the brain. This study aims to provide a real-time signal quality assessment method to help clinical personnel in placement of the fNIRS sensors on head to ensure good signal quality. Signal was segmented for each 10 seconds and a band-pass filter at 0.5-3 Hz was applied to isolate signal in cardiac band. Each segmented signal was subject to visual quality assessment to get bad, fair, and good labels. We used maximum to mean power ratio to generate signal quality index (SQI) score. Other methods included were skewness and kurtosis of the heart rate variability (HRV). Results showed that power ratio provides better consistency and separation among three different labels. Both skewness and kurtosis failed to separate fair and good segments. Using two threshold values, indices from power ration can be transformed into red (bad), yellow (fair), and green (good) alarm to help healthcare practitioners, who have no expertise to assess signal quality, to fix sensor placement to get good or acceptable signals.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Design and Implementation of Signal Generator and Real-time Analysis System
    Song Jie
    Yuan Hang
    Guan Chengbin
    Long Teng
    He You
    [J]. 2013 25TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2013, : 4517 - 4520
  • [22] Implementation of a portable device for real-time ECG signal analysis
    Jeon, Taegyun
    Kim, Byoungho
    Jeon, Moongu
    Lee, Byung-Geun
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [23] Towards Real-time Image Quality Assessment
    Geary, Bobby
    Grecos, Christos
    [J]. REAL-TIME IMAGE AND VIDEO PROCESSING 2011, 2011, 7871
  • [24] Real-time Video Quality Assessment Platform
    Papp, Istvan
    Lukic, Nemanja
    Marceta, Zoran
    Teslic, Nikola
    [J]. 2009 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, 2009, : 215 - +
  • [25] Optimizing spatial specificity and signal quality in fNIRS: an overview of potential challenges and possible options for improving the reliability of real-time applications
    Klein, Franziska
    [J]. FRONTIERS IN NEUROERGONOMICS, 2024, 5
  • [26] LSTM-based real-time signal quality assessment for blood volume pulse analysis
    Gao, Haoyuan
    Zhang, Chao
    Pei, Shengbing
    Wu, Xiaopei
    [J]. BIOMEDICAL OPTICS EXPRESS, 2023, 14 (03) : 1119 - 1136
  • [27] Real-Time PPG Signal Quality Assessment System for Improving Battery Life and False Alarms
    Vadrevu, Simhadri
    Manikandan, M. Sabarimalai
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2019, 66 (11) : 1910 - 1914
  • [28] Signal quality and Bayesian signal processing in neurofeedback based on real-time fMRI
    Koush, Yury
    Zvyagintsev, Mikhail
    Dyck, Miriam
    Mathiak, Krystyna A.
    Mathiak, Klaus
    [J]. NEUROIMAGE, 2012, 59 (01) : 478 - 489
  • [29] SDR Implementation of a Testbed for Real-Time Interference Detection With Signal Cancellation
    Politis, Christos
    Maleki, Sina
    Duncan, Juan Merlano
    Krivochiza, Jevgenij
    Chatzinotas, Symeon
    Ottesten, Bjorn
    [J]. IEEE ACCESS, 2018, 6 : 20807 - 20821
  • [30] Irregular Sampling of GPS Signal for Real-time Implementation of Pipelined PFFT
    Huang, Jianhua
    Luo, Gaoyong
    [J]. COMPUTER AND INFORMATION TECHNOLOGY, 2014, 519-520 : 969 - 974