Implementation of a real-time fNIRS signal quality assessment

被引:0
|
作者
Ferdinando, Hany [1 ]
Ilvesmaki, Martti [1 ]
Tone, Patricia-Elena [1 ]
Rahayu, Triana [1 ]
Moradi, Sadegh [2 ]
Myllyla, Teemu [1 ,2 ]
机构
[1] Univ Oulu, Fac Med, Res Unit Hlth Sci & Technol, Oulu, Finland
[2] Univ Oulu, Optoelet & Measurement Tech Res Unit, Oulu, Finland
关键词
fNIRS; signal quality index; power ratio; skewness; kurtosis; INDEX;
D O I
10.1117/12.3005688
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Signal quality is crucial in any signal analysis. Typically, the reason for bad signal quality is inappropriate sensor placement which is also highly dependent on the measurement location. It is usually quite easy to get a good optical signal from finger, but not from the brain. This study aims to provide a real-time signal quality assessment method to help clinical personnel in placement of the fNIRS sensors on head to ensure good signal quality. Signal was segmented for each 10 seconds and a band-pass filter at 0.5-3 Hz was applied to isolate signal in cardiac band. Each segmented signal was subject to visual quality assessment to get bad, fair, and good labels. We used maximum to mean power ratio to generate signal quality index (SQI) score. Other methods included were skewness and kurtosis of the heart rate variability (HRV). Results showed that power ratio provides better consistency and separation among three different labels. Both skewness and kurtosis failed to separate fair and good segments. Using two threshold values, indices from power ration can be transformed into red (bad), yellow (fair), and green (good) alarm to help healthcare practitioners, who have no expertise to assess signal quality, to fix sensor placement to get good or acceptable signals.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Using fNIRS for Real-Time Cognitive Workload Assessment
    Hincks, Samuel W.
    Afergan, Daniel
    Jacob, Robert J. K.
    [J]. FOUNDATIONS OF AUGMENTED COGNITION: NEUROERGONOMICS AND OPERATIONAL NEUROSCIENCE, AC 2016, PT I, 2016, 9743 : 198 - 208
  • [2] Real-time fNIRS signal acquisition system: Compatible with TMS
    Wang, Kai
    Chen, He
    Li, Xiaoli
    [J]. 2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 2338 - 2341
  • [3] Implementation of a Real-time ECG Signal Processor
    Chien, Shih-Yu Chang
    Hsieh, Cheng-Han
    Lin, Mark Po-Hung
    Fang, Qiang
    Lee, Shuenn-Yuh
    [J]. 2014 IEEE INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2014,
  • [4] ACOUSTOOPTIC IMPLEMENTATION OF REAL-TIME AND NEAR-REAL-TIME SIGNAL PROCESSING
    BERG, NJ
    LEE, JN
    CASSEDAY, MW
    [J]. OPTICAL ENGINEERING, 1979, 18 (04) : 420 - 428
  • [5] Real-time Signal Quality Assessment for ECGs Collected Using Mobile Phones
    Liu, Chengyu
    Li, Peng
    Zhao, Lina
    Liu, Feifei
    Wang, Ruxiang
    [J]. 2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 357 - 360
  • [6] Design and Implementation of A Real-time Capsule Endoscope Image Quality Assessment Method
    Zhang, T.
    Wang, L.
    Gu, J.
    Deng, Y. J.
    Li, X. D.
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1962 - +
  • [7] Hardware implementation of real-time SAR signal processor
    Huang, Jian-xi
    Wu, Jing-hong
    Huang, Shun-ji
    [J]. IEEE National Radar Conference - Proceedings, 2000, : 205 - 209
  • [8] The hardware implementation of real-time SAR signal processor
    Huang, JX
    Wu, JH
    Huang, SJ
    [J]. RECORD OF THE IEEE 2000 INTERNATIONAL RADAR CONFERENCE, 2000, : 205 - 209
  • [9] Optimal implementation of real-time GPS signal simulator
    Vaidehi, V
    Prasad, SVMK
    Ramakrishna, PV
    Krishnan, CN
    [J]. International Conference on Computing, Communications and Control Technologies, Vol 3, Proceedings, 2004, : 139 - 144
  • [10] Implementation of Real-Time MTIE Assessment Method
    Dobrogowsk, Andrzej
    Kasznia, Michal
    [J]. 2011 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM/EUROPEAN FREQUENCY AND TIME FORUM PROCEEDINGS, 2011, : 304 - 309