The detection of elemental content changes in electrode coating using laser-induced breakdown spectroscopy

被引:0
|
作者
Yang, Lei [1 ]
Li, Yinchuan [1 ]
Pan, Congyuan [2 ]
Bao, Wenyi [1 ]
Qin, Lei [1 ]
Dong, Jingtao [1 ]
Xu, Mengjie [1 ]
Ji, Feng [1 ]
Zhang, Yuzhong [1 ]
Lu, Rongsheng [1 ]
机构
[1] Hefei Univ Technol, Anhui Prov Engn Res Ctr Semicond Inspection Techno, Sch Instrument Sci & Optoelect Engn, Anhui Prov Key Lab Measuring Theory & Precis Instr, Hefei 230009, Anhui, Peoples R China
[2] Anhui Prov Hefei GStar Intelligent Control Tech Co, Hefei 230088, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser-induced breakdown spectroscopy; lithium battery; Electrode coating; Elemental content change; Internal mixed matrix; QUANTITATIVE-ANALYSIS; CATHODE; PERFORMANCE; CALIBRATION; LI; NANOPARTICLES; SPECTROMETRY;
D O I
10.1016/j.sab.2024.106896
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The elemental content of battery electrode coating is prone to change due to the production technology and ambient factors. To ensure the consistent performance and safety of a lithium battery, the elemental content of the electrode coating needs to be kept strictly consistent. This study proposes an internal mixed matrix method that combines laser-induced breakdown spectroscopy and chemometric method to achieve rapid and accurate detection of elemental content changes in electrode coating. The stoichiometric ratios of analytical elements are calculated by using the spectra of laser-induced breakdown spectroscopy. The relationships between that stoichiometric ratios and the actual content of analytical elements are studied and show that they are linear. Thus, the content change of the analytical element can be determined by calculating the change of the stoichiometric ratio. The average relative errors for content changes of iron, lithium, and phosphorus are 6.43%, 2.96%, and 4.12%, respectively, and the lowest detection limits are 278.2 mg/kg, 20.5 mg/kg, and 105.4 mg/kg, respectively. Furthermore, the internal reference method is proposed to correct the effect of ambient gases and improve detection accuracy. The results are that when Fe I 372.751 nm and Fe I 373.485 nm are used as analytical lines, after correcting for the effect of ambient gases, the average relative errors of Fe content changes are reduced by 62% and 72%, respectively, and the lowest detection limits are increased by 67% and 71%, respectively.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] DETERMINATION OF CARBON CONTENT IN STEEL USING LASER-INDUCED BREAKDOWN SPECTROSCOPY
    AGUILERA, JA
    ARAGON, C
    CAMPOS, J
    APPLIED SPECTROSCOPY, 1992, 46 (09) : 1382 - 1387
  • [32] Detection of uranium in solids by using laser-induced breakdown spectroscopy combined with laser-induced fluorescence
    Shen, X. K.
    Lu, Y. F.
    APPLIED OPTICS, 2008, 47 (11) : 1810 - 1815
  • [33] Approach to detection in laser-induced breakdown spectroscopy
    Mueller, M.
    Gornushkin, I. B.
    Florek, S.
    Mory, D.
    Panne, U.
    ANALYTICAL CHEMISTRY, 2007, 79 (12) : 4419 - 4426
  • [34] Detection of explosives with laser-induced breakdown spectroscopy
    Wang, Qian-Qian
    Liu, Kai
    Zhao, Hua
    Ge, Cong-Hui
    Huang, Zhi-Wen
    FRONTIERS OF PHYSICS, 2012, 7 (06) : 701 - 707
  • [35] Application of Laser-Induced Breakdown Spectroscopy in Detection of Cadmium Content in Rice Stems
    Wang, Wei
    Kong, Wenwen
    Shen, Tingting
    Man, Zun
    Zhu, Wenjing
    He, Yong
    Liu, Fei
    Liu, Yufei
    FRONTIERS IN PLANT SCIENCE, 2020, 11
  • [36] Elemental analysis of single ambient aerosol particles using laser-induced breakdown spectroscopy
    Heikkila, Paavo
    Rostedt, Antti
    Toivonen, Juha
    Keskinen, Jorma
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [37] Elemental analysis of single ambient aerosol particles using laser-induced breakdown spectroscopy
    Paavo Heikkilä
    Antti Rostedt
    Juha Toivonen
    Jorma Keskinen
    Scientific Reports, 12
  • [38] Ablation Properties and Elemental Analysis of Silicone Rubber Using Laser-Induced Breakdown Spectroscopy
    Wang, Xilin
    Wang, Han
    Chen, Can
    Jia, Zhidong
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (11) : 2766 - 2771
  • [39] Determination of elemental impurities in plastic calibration standards using laser-induced breakdown spectroscopy
    Ayyalasomayajula, Krishna K.
    McIntyre, Dustin L.
    Jain, Jinesh
    Singh, Jagdish P.
    Fang Yu-Yueh
    APPLIED OPTICS, 2012, 51 (07) : B143 - B148
  • [40] An Optimized Calibration Procedure for Determining Elemental Ratios Using Laser-Induced Breakdown Spectroscopy
    Frydenvang, Jens
    Kinch, Kjartan Munster
    Husted, Soren
    Madsen, Morten Bo
    ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1492 - 1500