Electronic cleansing in CT colonography using transformer-based UNet

被引:0
|
作者
Tachibana, Rie [1 ,2 ,3 ]
Nappi, Janne J. [2 ,3 ]
Okamoto, Masaki [4 ]
Yoshida, Hiroyuki [2 ,3 ]
机构
[1] Natl Inst Technol, Oshima Coll, Dept Informat Sci & Technol, 1091-1 Komatsu Suo-Oshima, Oshima 7422193, Japan
[2] Massachusetts Gen Hosp, Dept Radiol, 3D Imaging Res, 125 Nashua St,Suite 260, Boston, MA 02114 USA
[3] Harvard Med Sch, 125 Nashua St,Suite 260, Boston, MA 02114 USA
[4] Boston Med Sci Inc, 3-7-2 Nihonbashi honcho,Chuo Ku, Tokyo 1030023, Japan
关键词
Deep learning; virtual cleansing; image quality assessment; machine learning; virtual colonoscopy;
D O I
10.1117/12.3006129
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We developed a novel 3D transformer-based UNet method for performing electronic cleansing (EC) in CT colonography (CTC). The method is designed to map an uncleansed CTC image volume directly into the corresponding virtually cleansed CTC image volume. In the method, the layers of a 3D transformer-based encoder are connected via skip connections to the decoder layers of a 3D UNet to enhance the ability of the UNet to use long-distance image information for resolving EC image artifacts. The EC method was trained by use of the CTC image volumes of an anthropomorphic phantom that was filled partially with a mixture of foodstuff and an iodinated contrast agent. The CTC image volume of the corresponding empty phantom was used as the reference standard. The quality of the EC images was tested visually with six clinical CTC test cases and quantitatively based on a phantom test set of 100 unseen samples. The image quality of EC was compared with that of a conventional 3D UNet-based EC method. Our preliminary results indicate that the 3D transformer-based UNet EC method is a potentially effective approach for optimizing the performance of EC in CTC.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Digital subtraction bowel cleansing for CT colonography using morphological and linear filtration methods
    Zalis, ME
    Perumpillichira, J
    Hahn, PE
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (11) : 1335 - 1343
  • [42] Electronic cleansing and stool tagging in CT colonography: Advantages and pitfalls with primary three-dimensional evaluation
    Pickhardt, PJ
    Choi, JHR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) : 799 - 805
  • [43] Self-supervised generative adversarial network for electronic cleansing in dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2020: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2020, 11318
  • [44] TransDose: a transformer-based UNet model for fast and accurate dose calculation for MR-LINACs
    Xiao, Fan
    Cai, Jiajun
    Zhou, Xuanru
    Zhou, Linghong
    Song, Ting
    Li, Yongbao
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (12):
  • [45] ResTrans-Unet: A Residual-Aware Transformer-Based Approach to Medical Image Segmentation
    Ma, Fengying
    Wang, Zhi
    Ji, Peng
    Fu, Chengcai
    Wang, Feng
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2024, 34 (04)
  • [46] SOAT-UNET: a transformer-based Siamese over-attention network for change detection
    Sun, Xuhui
    Fu, Bowen
    Jiang, Xiangyuan
    Ma, Xiaojing
    Ma, Sile
    SIGNAL IMAGE AND VIDEO PROCESSING, 2023, 17 (08) : 4275 - 4283
  • [47] SOAT-UNET: a transformer-based Siamese over-attention network for change detection
    Xuhui Sun
    Bowen Fu
    Xiangyuan Jiang
    Xiaojing Ma
    Sile Ma
    Signal, Image and Video Processing, 2023, 17 : 4275 - 4283
  • [48] LTUNet: A Lightweight Transformer-Based UNet with Multi-scale Mechanism for Skin Lesion Segmentation
    Guo, Huike
    Zhang, Han
    Li, Minghe
    Quan, Xiongwen
    ARTIFICIAL INTELLIGENCE, CICAI 2023, PT II, 2024, 14474 : 147 - 158
  • [49] Video captioning using transformer-based GAN
    Babavalian M.R.
    Kiani K.
    Multimedia Tools and Applications, 2025, 84 (10) : 7091 - 7113
  • [50] Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions
    Xu, Yonghua
    Cai, Wenli
    Nappi, Janne
    Yoshida, Hiro
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : 1712 - 1716