EXPERIMENTAL ANALYSIS OF DYNAMIC OPERATIONS OF THE MAIN STEAM RELIEF ISOLATION VALVE USED IN NUCLEAR POWER PLANTS

被引:0
|
作者
Zhou, Weihao [1 ]
Zong, Chaoyong [1 ]
Li, Qingye [1 ]
Jiang, Songzhi [2 ]
Liu, Yanliang [2 ]
Song, Xueguan [1 ]
机构
[1] Dalian Univ Technol, Sch Mech Engn, Dalian 116023, Peoples R China
[2] Dalian DV Valve Co Ltd, Dalian 116037, Peoples R China
基金
中国国家自然科学基金;
关键词
Main steam relief isolation valve; experimental analysis; opening time; closing time; throttle area; CFD ANALYSIS; REACTOR;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Main steam relief isolation valve (MSRIV) is one type of advanced control valve used in pressurized water reactors (PWR), such as Hualong One (HPR 1000 in China) and European Pressurized Reactor (EPR). It can provide overpressure protection for the steam generator (SG) and used for waste heat discharging. However, MSRIV may show undesirable operations such as reclose slow under high pressure & temperature conditions (e.g., 8.9 MPa & 316 degrees C) and/or cannot be opened timely under low pressure & temperature conditions (e.g., 0.14 MPa & 316 degrees C). To explore the root causes of these undesirables, an experimental based analysis was specially carried out in this paper. For valve performance measurement, an experimental test rig was developed, thereby not only dynamic responses of the MSRIV under different operating conditions, but also the influence of valve key parameters can be analyzed. The results show that both the system pressure and the throttle area have great influence on the dynamics of the MSRIV. Upon the same disk throttle area, the valve opening time decrease with the inlet pressure, while the valve reclosing time increase with it. For the same inlet pressures, larger throttle area usually led to longer valve opening time and the shorter valve closing time. The results obtained in this study not only provide a reference for the valve early design stage, but also can be used as a criterion for the subsequent numerical modeling works which is of great importance for the flow details acquisition and valve mechanism exploration.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Ageing Analysis of Power Cables used in Nuclear Power Plants
    Abro, Shahid Hussain
    Shah, Syed Aqeel Ahmed
    Alaboodi, Abdulaziz Solaiman
    Shoaib, Talha
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2020, 39 (01) : 195 - 204
  • [22] AN EARTHQUAKE ISOLATION SYSTEM FOR STEAM-GENERATORS IN NUCLEAR-POWER PLANTS
    BHATTI, MA
    CIAMPI, V
    KELLY, JM
    PISTER, KS
    NUCLEAR ENGINEERING AND DESIGN, 1982, 73 (03) : 229 - 252
  • [23] NUMERICAL SIMULATION OF PRESSURE TRANSIENTS IN A PWR MAIN STEAM LINE SYSTEM DUE TO QUICK OPERATIONS OF PRESSURE RELIEF VALVE
    Jo, Jong Chull
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE 2009, VOL 4, 2010, : 35 - 43
  • [24] STUDY ON LOAD CAPACITY OF MAIN STEAM SUPERPIPE NOZZLE USED IN NUCLEAR POWER PLANT
    Zhou Gengyu
    Liang Shuhua
    Sun Lin
    Lv Feng
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [25] THE MAIN FEATURES OF CONTROL AND OPERATION FOR STEAM-TURBINES AT NUCLEAR-POWER PLANTS
    CZINKOCZKY, B
    ENERGIA ES ATOMTECHNIKA, 1981, 34 (10): : 449 - 456
  • [26] Unit for the Heat Treatment and Straightening of Tubes Used in the Steam Generators of Nuclear Power Plants
    Burkin, S. P.
    Shimov, G. V.
    Serebryakov, An. V.
    Serebryakov, Al. V.
    METALLURGIST, 2016, 60 (1-2) : 61 - 68
  • [27] Unit for the Heat Treatment and Straightening of Tubes Used in the Steam Generators of Nuclear Power Plants
    S. P. Burkin
    G. V. Shimov
    An. V. Serebryakov
    Al. V. Serebryakov
    Metallurgist, 2016, 60 : 61 - 68
  • [28] Analysis of pressure oscillations and safety relief valve vibrations in the main steam system of a Boiling Water Reactor
    Galbally, David
    Garcia, Gonzalo
    Hernando, Jesus
    Sanchez, Juan de Dios
    Barral, Marcos
    NUCLEAR ENGINEERING AND DESIGN, 2015, 293 : 258 - 271
  • [29] Cause Analysis and Solution of Main Steam Pipe Vibration in a Nuclear Power Plant
    某核电厂主蒸汽管道振动原因分析及解决方案探讨
    Zhan, Minming (zhanminming@snerdi.com.cn), 1600, Atomic Energy Press (42): : 138 - 142
  • [30] Experimental analysis of droplet impacting on inclined wall of the corrugated plate dryer in steam generator of nuclear power plants
    Li Ru
    Chen Bowen
    Wang Weibing
    Wang Bo
    Tian Ruifeng
    ANNALS OF NUCLEAR ENERGY, 2022, 172