Techno-economic evaluation and comparison of the optimal PV/Wind and grid hybrid system with horizontal and vertical axis wind turbines

被引:12
|
作者
Irshad, Ahmad Shah [1 ,2 ]
Kargar, Nqibullah [3 ]
Elkholy, M. H. [1 ,5 ]
Ludin, Gul Ahmad [1 ]
Elias, Said [4 ,6 ,9 ]
Hilali, Ahmadullah [4 ]
Senjyu, Tomonobu [1 ]
M.Gamil, Mahmoud [5 ]
Pinter, Gabor [7 ,8 ]
机构
[1] Univ Ryukyus, Fac Engn, Dept Elect & Elect Engn, Nishihara, Okinawa 9030213, Japan
[2] Kandahar Univ, Engn Fac, Dept Energy Engn, Kandahar 3801, Afghanistan
[3] Kandahar Univ, Engn Fac, Dept Architecture Engn, Kandahar 3801, Afghanistan
[4] Kandahar Univ, Engn Fac, Dept Civil Engn, Kandahar 3801, Afghanistan
[5] Zagazig Univ, Fac Engn, Elect Power & Machines, Zagazig 44519, Egypt
[6] Leibniz Univ Hannover, Inst Risk & Reliabil, Hannover, Germany
[7] Univ Pannonia, Fac Engn, Soos Erno Res & Dev Ctr, Renewable Energy Res Grp, H-8200 Veszprem, Hungary
[8] Western Caspian Univ, Baku, Azerbaijan
[9] Leibniz Univ Hannover LUH, Inst Risk & Reliabil, Marie Sklodowska Curie Act MSCA, Hannover, Germany
关键词
Renewable energy; Wind energy; Grid energy; Cost of energy; Net present cost; RENEWABLE ENERGY SYSTEM; RURAL ELECTRIFICATION; POWER-GENERATION; OPTIMIZATION; FEASIBILITY; DESIGN; SOLAR;
D O I
10.1016/j.ecmx.2024.100638
中图分类号
O414.1 [热力学];
学科分类号
摘要
Applications for alternative energy sources range from very small scale to large scale grid-coupled hybrid energy systems. In addition, hybrid energy systems are safer to generate power and cheaper to produce than singlesource energy systems. The main goal of this study is to determine whether renewable energy hybrid system with horizontal axis wind turbine (HAWT) or vertical axis wind turbine (VAWT) is more efficient and cost effective in terms of energy, economics, and environmental performance. The use of the Multi Objective Genetic Algorithm (MOGA) in MATLAB software for the sizing of hybrid sustainable energy system with wind turbine (horizontal and vertical axis), solar photovoltaic, and grid connection is evaluated in this study. The results revealed that the cost of energy, NPC and system total cost for the case where HRES consists of HAWT is $0.02 /kWh, $85,905, and $332,240, respectively, while for the case when VAWT is used, these values are $0.06 /kWh, $129,932 and $502,511, respectively. The renewable fraction and CO 2 emission saving are 80.5% and 73.2% for cases 1 and 2, respectively. The use of renewable energy sources will spread more widely and there will be less air pollution as a result of less reliance on grid electricity. The findings from both situations show that adopting HAWTS-based HRESs is more cost effective and efficient for electrifying rural areas. This study paves the way for researchers to focus on types of wind turbines while designing HRESs.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] Techno-Economic Modeling of Wind-Solar PV and Wind-Solar PV-Biomass Hybrid Energy System
    Jagtap, Kunal K.
    Patil, Ganesh
    Katti, P. K.
    Kulkarni, S. B.
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [12] Techno-economic evaluation of a grid-connected hybrid PV-Wind power generation system in San Luis Potosi, Mexico
    Ospino-Castro, Adalberto
    Pena-Gallardo, Rafael
    Hernandez-Rodriguez, Aurelio
    Segundo-Ramirez, Juan
    Munoz-Maldonado, Yecid A.
    2017 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2017,
  • [13] Diffuser augmented wind turbines - a case study for hybrid energy system applications and comparison with horizontal axis wind turbines
    Mohanan, Janesh N.
    Kumaravel, S.
    Ashok, S.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (03) : 6807 - 6822
  • [14] Techno-economic analysis of hybrid system (PV/wind/diesel generator/grid) for domestic consumers in balochistan (nokkundi & ormara)
    Niazi, Irfan Khan
    Khan, Muhammad Bilal
    Wazir, Rashid
    WORLD JOURNAL OF ENGINEERING, 2015, 12 (01) : 29 - 35
  • [15] Energy and exergy efficiency comparison of horizontal and vertical axis wind turbines
    Pope, K.
    Dincer, I.
    Naterer, G. F.
    RENEWABLE ENERGY, 2010, 35 (09) : 2102 - 2113
  • [16] Techno-economic analysis of off-grid PV/wind/fuel cell hybrid system combinations with a comparison of regularly and seasonally occupied households
    Duman, A. Can
    Guler, Onder
    SUSTAINABLE CITIES AND SOCIETY, 2018, 42 : 107 - 126
  • [17] AERODYNAMIC PERFORMANCE OF VERTICAL AND HORIZONTAL AXIS WIND TURBINES
    MAYDEW, RC
    KLIMAS, PC
    JOURNAL OF ENERGY, 1981, 5 (03): : 189 - 190
  • [18] Techno-Economic and Sensitivity Analysis of Grid Connected Perovskite PV-Wind Systems
    Nazir, Masood Ibni
    Selim, F.
    Ahmad, Aijaz
    Hussain, Ikhlaq
    Dawoud, Samir M.
    Alluhaybi, Khalil
    Zaky, Alaa A.
    IEEE ACCESS, 2024, 12 : 78397 - 78408
  • [19] Techno-economic evaluation of an off-grid hybrid PV-wind-diesel-battery system with various scenarios of system?s renewable energy fraction
    Almashakbeh, Atef S.
    Arfoa, Aouda A.
    Hrayshat, Eyad S.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (02) : 6162 - 6185
  • [20] Optimal techno-economic design of hybrid PV/wind system comprising battery energy storage: Case study for a remote area
    Emad, D.
    El-Hameed, M.A.
    El-Fergany, A.A.
    Energy Conversion and Management, 2021, 249