Generation of LiF(Mg,Cu,Na,Si) thermoluminescent crystal and evaluation of dose response and sensitivity

被引:1
|
作者
Khorshidi, Abdollah [1 ,2 ,3 ]
机构
[1] Nucl Sci & Technol Res Inst, Radiat Applicat Res Sch, Tehran, Iran
[2] Gerash Univ Med Sci, Sch Paramed, Gerash, Iran
[3] Qaem Univ, Cent Branch, Kerman, Iran
关键词
Thermoluminescent dosimeter; Crystal impurity; Detector sensitivity; Dose response; DOSIMETRIC CHARACTERISTICS; LIF; DEPENDENCE; TLD-100;
D O I
10.1016/j.net.2024.02.041
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this research, thermoluminescent pellets were prepared by adding Mg, Cu, Na and Si impurities to lithium fluoride (LiF) crystal powder via melting and quenching methods to study dosimetric characteristics. Here, its reproducibility, dose response, dosimeter sensitivity, thermal and optical fading were investigated and the obtained results were compared with the properties of LiF: Cu, Mg, P crystal nominated as GR-200.
引用
收藏
页码:2790 / 2798
页数:9
相关论文
共 50 条
  • [41] Behaviour of LiF:Mg,Cu,P and LiF:Mg,Ti thermoluminescent detectors for electron doses up to 1 MGy
    Bilski, Pawel
    Obryk, Barbara
    Stuglik, Zofia
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 576 - 578
  • [42] Preparation and thermoluminescent dosimetry features of high sensitivity LiF:Mg,Ce phosphor
    Shoushtari, M. K.
    Zahedifar, M.
    Sadeghi, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 887 : 128 - 132
  • [43] Dose re-evaluation in personal dosimetry using the phototransferred thermoluminescence method of LiF:Mg,Cu,Si TLD
    Kim, Hyoungtaek
    Kim, Min Chae
    Lee, Jungil
    Chang, Insu
    Lee, Seung Kyu
    Kim, Jang-Lyul
    RADIATION MEASUREMENTS, 2018, 118 : 20 - 25
  • [44] Dependence of glow curve structure on the concentration of dopants in LiF:Mg,Cu,Na,Si phosphor
    Nam, YM
    Kim, JL
    Chang, SY
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 231 - 234
  • [45] A personal thermoluminescence dosimeter using LiF:Mg,Cu,Na,Si detectors for photon fields
    Jung, HY
    Lee, KJ
    Kim, JL
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (01) : 87 - 93
  • [46] Optically stimulated luminescence dosimetry on tissue equivalent LiF: Mg, Cu, Na, Si phosphor
    Seth, Pooja
    Aggarwal, Shruti
    Bahl, Shaila
    Kumar, Pratik
    OPTIK, 2022, 260
  • [47] The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments
    Mohammadi, Kheirollah
    Khayat, Omid
    Afarideh, Hossein
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (01) : 19 - 26
  • [48] Sensitivity loss and recovery for individual TL peaks in LiF:Mg,Ti and LiF:Mg,Cu,P after high-dose irradiation
    Bilski, P.
    Cybulski, T.
    Puchalska, M.
    Ptaszkiewicz, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 357 - 360
  • [49] The Response of LiF:Mg, Ti Thermoluminescent Dosimeters to Low-Energy Photons
    Rasmussen, B.
    Davis, S.
    Micka, J.
    DeWerd, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [50] DOSE REASSESSMENT OF LIF-MG,CU,P
    DRISCOLL, CMH
    RADIATION PROTECTION DOSIMETRY, 1987, 19 (01) : 59 - 61