Recording the tactile P300 with the cEEGrid for potential use in a brain-computer interface

被引:0
|
作者
Eidel, M. [1 ]
Pfeiffer, M. [1 ]
Ziebell, P. [1 ]
Kuebler, A. [1 ]
机构
[1] Univ Wurzburg, Inst Psychol, Wurzburg, Germany
来源
关键词
brain-computer interface (BCI); P300-event-related potential; tactile P300; tactually evoked potentials; somatosensory sensitivity; CENTERED DESIGN; COMMUNICATION; TECHNOLOGY; ODDBALL; BCI; DISCRIMINATION; PARTICIPANTS; PROBABILITY; PEOPLE; P3A;
D O I
10.3389/fnhum.2024.1371631
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Brain-computer interfaces (BCIs) are scientifically well established, but they rarely arrive in the daily lives of potential end-users. This could be in part because electroencephalography (EEG), a prevalent method to acquire brain activity for BCI operation, is considered too impractical to be applied in daily life of end-users with physical impairment as an assistive device. Hence, miniaturized EEG systems such as the cEEGrid have been developed. While they promise to be a step toward bridging the gap between BCI development, lab demonstrations, and home use, they still require further validation. Encouragingly, the cEEGrid has already demonstrated its ability to record visually and auditorily evoked event-related potentials (ERP), which are important as input signal for many BCIs. With this study, we aimed at evaluating the cEEGrid in the context of a BCI based on tactually evoked ERPs. To compare the cEEGrid with a conventional scalp EEG, we recorded brain activity with both systems simultaneously. Forty healthy participants were recruited to perform a P300 oddball task based on vibrotactile stimulation at four different positions. This tactile paradigm has been shown to be feasible for BCI repeatedly but has never been tested with the cEEGrid. We found distinct P300 deflections in the cEEGrid data, particularly at vertical bipolar channels. With an average of 63%, the cEEGrid classification accuracy was significantly above the chance level (25%) but significantly lower than the 81% reached with the EEG cap. Likewise, the P300 amplitude was significantly lower (cEEGrid R2-R7: 1.87 mu V, Cap Cz: 3.53 mu V). These results indicate that a tactile BCI using the cEEGrid could potentially be operated, albeit with lower efficiency. Additionally, participants' somatosensory sensitivity was assessed, but no correlation to the accuracy of either EEG system was shown. Our research contributes to the growing amount of literature comparing the cEEGrid to conventional EEG systems and provides first evidence that the tactile P300 can be recorded behind the ear. A BCI based on a thus simplified EEG system might be more readily accepted by potential end-users, provided the accuracy can be substantially increased, e.g., by training and improved classification.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Prediction of Auditory and Visual P300 Brain-Computer Interface Aptitude
    Halder, Sebastian
    Hammer, Eva Maria
    Kleih, Sonja Claudia
    Bogdan, Martin
    Rosenstiel, Wolfgang
    Birbaumer, Niels
    Kuebler, Andrea
    PLOS ONE, 2013, 8 (02):
  • [32] A P300 auditory brain-computer interface based on mental repetition
    Marassi, Alessandro
    Budai, Riccardo
    Chittaro, Luca
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (03):
  • [33] Using a P300 Brain-Computer Interface in an Immersive Virtual Environment
    Donnerer, Michael
    Steed, Anthony
    PRESENCE-TELEOPERATORS AND VIRTUAL ENVIRONMENTS, 2010, 19 (01) : 12 - 24
  • [34] P300 brain-computer interface design for communication and control applications
    Wang, Chaunchu
    Guan, Cuntai
    Zhang, Haihong
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5400 - 5403
  • [35] A region-based P300 speller for brain-computer interface
    Fazel-Rezai, Reza
    Abhari, Kamyar
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2009, 34 (03): : 81 - 85
  • [36] Human error in P300 speller paradigm for brain-computer interface
    Fazel-Rezai, Reza
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2516 - 2519
  • [37] SUBOPTIMAL SENSOR SUBSET EVALUATION IN A P300 BRAIN-COMPUTER INTERFACE
    Cecotti, H.
    Rivet, B.
    Congedo, M.
    Jutten, C.
    Bertrand, O.
    Maby, E.
    Mattout, J.
    18TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO-2010), 2010, : 924 - 928
  • [38] A Potential Prognosis Indicator Based on P300 Brain-Computer Interface for Patients with Disorder of Consciousness
    Li, Jingcong
    Huang, Biao
    Wang, Fei
    Xie, Qiuyou
    Xu, Chengwei
    Huang, Haiyun
    Pan, Jiahui
    BRAIN SCIENCES, 2022, 12 (11)
  • [39] Brain-computer interfaces -: Communication with the P300
    Kübler, A
    Nijboer, F
    Mellinger, J
    Matuz, T
    Kleber, B
    Eitel-Braitsch, Y
    Sellers, E
    Vaughan, T
    Wolpaw, J
    Birbaumer, N
    JOURNAL OF PSYCHOPHYSIOLOGY, 2005, 19 (02) : 128 - 128
  • [40] An innovative P300 speller brain-computer interface design: Easy screen
    Aygun, Abdullah Bilal
    Kavsaoglu, Ahmet Resit
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 75