Recording the tactile P300 with the cEEGrid for potential use in a brain-computer interface

被引:0
|
作者
Eidel, M. [1 ]
Pfeiffer, M. [1 ]
Ziebell, P. [1 ]
Kuebler, A. [1 ]
机构
[1] Univ Wurzburg, Inst Psychol, Wurzburg, Germany
来源
关键词
brain-computer interface (BCI); P300-event-related potential; tactile P300; tactually evoked potentials; somatosensory sensitivity; CENTERED DESIGN; COMMUNICATION; TECHNOLOGY; ODDBALL; BCI; DISCRIMINATION; PARTICIPANTS; PROBABILITY; PEOPLE; P3A;
D O I
10.3389/fnhum.2024.1371631
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Brain-computer interfaces (BCIs) are scientifically well established, but they rarely arrive in the daily lives of potential end-users. This could be in part because electroencephalography (EEG), a prevalent method to acquire brain activity for BCI operation, is considered too impractical to be applied in daily life of end-users with physical impairment as an assistive device. Hence, miniaturized EEG systems such as the cEEGrid have been developed. While they promise to be a step toward bridging the gap between BCI development, lab demonstrations, and home use, they still require further validation. Encouragingly, the cEEGrid has already demonstrated its ability to record visually and auditorily evoked event-related potentials (ERP), which are important as input signal for many BCIs. With this study, we aimed at evaluating the cEEGrid in the context of a BCI based on tactually evoked ERPs. To compare the cEEGrid with a conventional scalp EEG, we recorded brain activity with both systems simultaneously. Forty healthy participants were recruited to perform a P300 oddball task based on vibrotactile stimulation at four different positions. This tactile paradigm has been shown to be feasible for BCI repeatedly but has never been tested with the cEEGrid. We found distinct P300 deflections in the cEEGrid data, particularly at vertical bipolar channels. With an average of 63%, the cEEGrid classification accuracy was significantly above the chance level (25%) but significantly lower than the 81% reached with the EEG cap. Likewise, the P300 amplitude was significantly lower (cEEGrid R2-R7: 1.87 mu V, Cap Cz: 3.53 mu V). These results indicate that a tactile BCI using the cEEGrid could potentially be operated, albeit with lower efficiency. Additionally, participants' somatosensory sensitivity was assessed, but no correlation to the accuracy of either EEG system was shown. Our research contributes to the growing amount of literature comparing the cEEGrid to conventional EEG systems and provides first evidence that the tactile P300 can be recorded behind the ear. A BCI based on a thus simplified EEG system might be more readily accepted by potential end-users, provided the accuracy can be substantially increased, e.g., by training and improved classification.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A tactile P300 brain-computer interface
    Brouwer, Anne-Marie
    van Erp, Jan B. F.
    FRONTIERS IN NEUROSCIENCE, 2010, 4
  • [2] An Optimizational Tactile P300 Brain-Computer Interface Paradigm
    Cao, Boyan
    Han, Xing
    Tang, Jingsheng
    Zhou, Zongtan
    Liu, Yadong
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 8215 - 8220
  • [3] Effects of Skin Friction on Tactile P300 Brain-Computer Interface Performance
    Mao, Ying
    Jin, Jing
    Li, Shurui
    Miao, Yangyang
    Cichocki, Andrzej
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2021, 2021
  • [4] A P300 Brain-Computer Interface Under the Hybrid Stimuli of P300 and SSVEP
    Jie, Ke
    Bi, Luzheng
    Lian, Jinling
    Zhao, Shuju
    INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION (ICECA 2014), 2014, : 509 - 514
  • [5] Communication for patients with disorders of consciousness with a vibro-tactile P300 brain-computer interface
    Ortner, Rupert
    Dinares-Ferran, Josep
    Murovec, Nensi
    Mayr, Katrin
    Cao, Fan
    Guger, Christoph
    2020 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2020, : 508 - 512
  • [6] A P300 Brain-Computer Interface for Lower Limb Robot Control Based on Tactile Stimulation
    Xiaoyu Duan
    Shijie Guo
    Lingling Chen
    Mengge Wang
    Journal of Medical and Biological Engineering, 2023, 43 : 22 - 31
  • [7] An Auditory-Tactile Visual Saccade-Independent P300 Brain-Computer Interface
    Yin, Erwei
    Zeyl, Timothy
    Saab, Rami
    Hu, Dewen
    Zhou, Zongtan
    Chau, Tom
    INTERNATIONAL JOURNAL OF NEURAL SYSTEMS, 2016, 26 (01)
  • [8] A P300 Brain-Computer Interface for Lower Limb Robot Control Based on Tactile Stimulation
    Duan, Xiaoyu
    Guo, Shijie
    Chen, Lingling
    Wang, Mengge
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2023, 43 (01) : 22 - 31
  • [9] Developing a Novel Tactile P300 Brain-Computer Interface With a Cheeks-Stim Paradigm
    Jin, Jing
    Chen, Zongmei
    Xu, Ren
    Miao, Yangyang
    Wang, Xingyu
    Jung, Tzyy-Ping
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (09) : 2585 - 2593
  • [10] Motivation modulates the P300 amplitude during brain-computer interface use
    Kleih, S. C.
    Nijboer, F.
    Halder, S.
    Kuebler, A.
    CLINICAL NEUROPHYSIOLOGY, 2010, 121 (07) : 1023 - 1031