Local voltage contrast changes in MOSFET using scanning electron microscopy with photoelectron beam technology

被引:0
|
作者
Sato, Daiki [1 ]
Arakawa, Yuta [1 ]
Niimi, Kotaro [1 ]
Fukuroi, Keika [1 ]
Tajiri, Yutaro [1 ]
Koizumi, Atsushi [1 ]
Shikano, Haruka [1 ]
Iijima, Hokuto [1 ]
Nishitani, Tomohiro [1 ]
Honda, Yoshio [2 ]
Amano, Hiroshi [2 ]
机构
[1] Photo Electron Soul Inc, 2-22-8 Chikusa,Chikusa Ku, Nagoya, Aichi 4640858, Japan
[2] Nagoya Univ, Inst Mat & Syst Sustainabil, Furo Cho,Chikusa Ku, Nagoya, Aichi 4648601, Japan
关键词
Electron gun; Semiconductor photocathode; Scanning electron microscope; Negative electron affinity; Voltage contrast; Pulsed electron beam; Defect inspection; Metrology;
D O I
10.1117/12.3009947
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Scanning electron microscopy (SEM) is used for metrology and inspection in semiconductor manufacturing. In addition, electrical defects such as short circuits and unintentional insulation appear as contrast differences called voltage contrast (VC) in SEM under low acceleration voltage conditions. Moreover, by using pulsed electron beams from a photocathode, the probe current can be arbitrarily changed by pixel in the SEM image. Using this technology, we succeeded in observing the change in the VC of the drain in the metal-oxide-semiconductor field effect transistor (MOSFET) by changing in electron beam irradiation on the gate only. In this study, to estimate the threshold voltage of n-type MOSFET (nMOS) from VC, we investigated quantitative changes in the specimen current of the drain (I-d) and the gate (I-g) due to gate e-beam irradiation ON/OFF during SEM imaging. The landing energy of the electron beam was set to 0.8 keV, the probe current was 6.3 pA, and the e-beam was irradiated onto only the gate and drain electrodes. I-d and I-g, which showed a positive value at the beginning, decreased with time, and saturated at negative values. When the electron beam irradiation to the gate was turned OFF, the Id decreased further and reached saturation. When the gate e-beam irradiation was turned ON again, I-g recovered to a positive and then saturated again to a negative value. On the other hand, the drain Id increased when the gate irradiation was turned ON and returned to the same value as before it was turned OFF.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] IMAGE CONTRAST IN HIGH VOLTAGE ELECTRON MICROSCOPY
    HUMPHREYS, CJ
    JERNKONTORETS ANNALER, 1971, 155 (08): : 459 - +
  • [42] The contrast mechanism in low voltage scanning electron microscopy of single-walled carbon nanotubes
    Zhang, RY
    Wei, Y
    Nagahara, LA
    Amlani, I
    Tsui, RK
    NANOTECHNOLOGY, 2006, 17 (01) : 272 - 276
  • [43] Increasing compositional backscattered electron contrast in scanning electron microscopy
    Timischl, F.
    Inoue, N.
    ULTRAMICROSCOPY, 2018, 186 : 82 - 93
  • [44] Electron-beam-induced deposition of carbonaceous microstructures using scanning electron microscopy
    Miura, N
    Ishii, H
    Shirakashi, J
    Yamada, A
    Konagai, M
    APPLIED SURFACE SCIENCE, 1997, 113 : 269 - 273
  • [45] SCANNING ELECTRON MICROSCOPY AND FOCUSED ION BEAM TECHNOLOGY ON CELL CULTURES FOR TISSUE ENGINEERING
    Staeudte, A.
    Hoess, A.
    Heilmann, A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 636 - 637
  • [46] Local structure analysis of disordered materials via contrast variation in scanning transmission electron microscopy
    Kimoto, Koji
    Shiga, Motoki
    Kohara, Shinji
    Kikkawa, Jun
    Cretu, Ovidiu
    Onodera, Yohei
    Ishizuka, Kazuo
    AIP ADVANCES, 2022, 12 (09)
  • [47] SOME OBSERVATIONS OF CONTRAST EFFECTS IN SCANNING ELECTRON MICROSCOPY
    TIXIER, R
    PHILIBER.J
    JOURNAL DE MICROSCOPIE, 1969, 8 (04): : A26 - &
  • [48] Phase-contrast scanning transmission electron microscopy
    Minoda, Hiroki
    Tamai, Takayuki
    Iijima, Hirofumi
    Hosokawa, Fumio
    Kondo, Yukihito
    MICROSCOPY, 2015, 64 (03) : 181 - 187
  • [49] Z-contrast scanning transmission electron microscopy
    Pennycook, SJ
    Nellist, PD
    IMPACT OF ELECTRON AND SCANNING PROBE MICROSCOPY ON MATERIALS RESEARCH, 1999, 364 : 161 - 207
  • [50] Local depth monitoring using scanning electron microscopy and its verification using atomic force microscopy
    Park, Inseok
    Ahn, JaeHyung
    Lee, Donghyun
    Kim, Souk
    Rim, Minho
    Sohn, Younghoon
    METROLOGY, INSPECTION, AND PROCESS CONTROL XXXVII, 2023, 12496