Analysis of Overvoltage and Backflashover with Different Transmission Line Models

被引:0
|
作者
Guevara, Jesus E. [1 ]
Colqui, Jaimis S. L. [1 ]
Pissolato Filho, Jose [1 ]
机构
[1] Univ Estadual Campinas, Sch Elect & Comp E, Campinas, SP, Brazil
来源
SOUTHEASTCON 2024 | 2024年
基金
巴西圣保罗研究基金会;
关键词
Lightning overvoltage; backflashover; transmission line; insulator string; lightning current;
D O I
10.1109/SOUTHEASTCON52093.2024.10500135
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Most research on the lightning overvoltage and backflashover phenomenon caused by direct lightning strikes use EMT programs considering the J. Marti model to represent transmission lines. Additionally, Carson's equations are used to compute the earth-return impedance. However, these equations disregard ground displacement current and assume that soil electrical properties are independent of frequency. Due to these disregards, simulations can produce incorrect findings and possibly even skip backflashover into existing insulator strings. In order to carry out the study of lightning overvoltage and backflashover, a real overhead transmission line in 440 kV was analyzed, getting results that there is backflashover when using the Pettersson transmission line model, even in two phases. However, it does not occur when Carson and Nakagawa models are used in some cases of lightning. Furthermore, considering high values of electrical resistivity of the ground will increase the lightning overvoltage in the insulator string. For example, when this value increases from 1000 to 10,000 Omega(sic)m, the lightning overvoltage increases by 249%.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [31] Lightning overvoltage suppression method based on magnetic ring for transmission line
    Zhou L.
    Hu C.
    Huang L.
    Wang D.
    Wu T.
    Zhang D.
    Chen S.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (06): : 186 - 191and198
  • [32] Study on Influencing Factors of Transmission Line Lightning Overvoltage with Impulse Corona
    Liu, Kai
    Bian, Xingming
    Lu, Tiebing
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [33] Influence of Gas-Insulated Transmission Line (GIL) on Energization Overvoltage
    Xu Wenjia
    Xiang Zutao
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3553 - 3560
  • [34] The Evaluation of Transmission Line Modeling on Lightning Performance Considering Surger Arresters: Impact in the Energy and Backflashover Rates
    Colqui, Jaimis S. L.
    Moura, Rodolfo A. R.
    Schroeder, Marco Aurelio O.
    Pissolato Filho, Jose
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2024, 35 (04) : 731 - 741
  • [35] Introducing novel risk-based indicator for determining transmission line tower's backflashover performance
    Sarajcev, P.
    Jakus, D.
    Vasilj, J.
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 160 : 337 - 347
  • [36] Switching Overvoltage Analysis in Conventional and Unconventional Transmission Lines
    Arafat, Easir
    Ghassemi, Mona
    2024 IEEE KANSAS POWER AND ENERGY CONFERENCE, KPEC 2024, 2024,
  • [37] Reduced order transmission line models for power system analysis
    Lefebvre, S
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1999, 21 (03) : 211 - 223
  • [38] Reduced order transmission line models for power system analysis
    Lefebvre, Serge
    International Journal of Electrical Power and Energy System, 1999, 21 (03): : 211 - 223
  • [39] Research on switching overvoltage in 1000 kV ultra-HVAC transmission line
    Xu, W., 2005, Chinese Society for Electrical Engineering (25):