Analysis of Overvoltage and Backflashover with Different Transmission Line Models

被引:0
|
作者
Guevara, Jesus E. [1 ]
Colqui, Jaimis S. L. [1 ]
Pissolato Filho, Jose [1 ]
机构
[1] Univ Estadual Campinas, Sch Elect & Comp E, Campinas, SP, Brazil
来源
基金
巴西圣保罗研究基金会;
关键词
Lightning overvoltage; backflashover; transmission line; insulator string; lightning current;
D O I
10.1109/SOUTHEASTCON52093.2024.10500135
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Most research on the lightning overvoltage and backflashover phenomenon caused by direct lightning strikes use EMT programs considering the J. Marti model to represent transmission lines. Additionally, Carson's equations are used to compute the earth-return impedance. However, these equations disregard ground displacement current and assume that soil electrical properties are independent of frequency. Due to these disregards, simulations can produce incorrect findings and possibly even skip backflashover into existing insulator strings. In order to carry out the study of lightning overvoltage and backflashover, a real overhead transmission line in 440 kV was analyzed, getting results that there is backflashover when using the Pettersson transmission line model, even in two phases. However, it does not occur when Carson and Nakagawa models are used in some cases of lightning. Furthermore, considering high values of electrical resistivity of the ground will increase the lightning overvoltage in the insulator string. For example, when this value increases from 1000 to 10,000 Omega(sic)m, the lightning overvoltage increases by 249%.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [1] Backflashover analysis of overhead transmission lines for different tower and lightning models
    Teixeira, CJC
    Pinto, JAD
    UPEC 2004: 39TH INTERNATIONAL UNIVERSITITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2005, : 238 - 241
  • [2] Multi-Region Soil Model for Transmission Line Backflashover Analysis
    Grange, Francois
    Botelho, Diego Pereira
    Journet, Sebastien
    Fortin, Simon
    Dawalibi, Farid P.
    2021 35TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP) AND XVI INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (SIPDA), 2021,
  • [3] Lightning Overvoltage Investigation due to a Backflashover Event in Transmission Lines: a realist modeling proposal
    Rodrigues, Andre Roger
    Boaventura, Wallace do Couto
    Guimaraes, Geraldo Caixeta
    Caixeta, Daniel Araujo
    Ribeiro Chaves, Marcelo Lynce
    Tamashiro, Marcio Augusto
    2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA), 2015, : 231 - 238
  • [4] Backflashover Analysis For 132 kV Kuala Krai-Gua Musang Transmission Line
    Sardi, J.
    Ab Kadir, M. Z. A.
    Ahmad, W. F. Wan
    Hizam, H.
    Rawi, I. Mohamed
    Ahmad, A.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 1494 - 1497
  • [5] Automatic simulation of transmission line backflashover rate base on ATP
    Lu Hailiang
    Wen Xishan
    Lan Lei
    Tong Xuefang
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1211 - 1215
  • [6] Analysis of Various Transmission Line Switching Overvoltage Limitation Techniques
    Golabi, Smko
    Tanhaeidilmaghani, Shahab
    Seyedi, Heresh
    2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,
  • [7] Assessment of the backflashover occurrence rate on HV transmission line towers
    Sarajcev, Petar
    Goic, Ranko
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2012, 22 (02): : 152 - 169
  • [8] Analysis of overvoltage and backflashover of an unified double-circuit OHTL-A case study
    Asorza, Jesus E. Guevara
    Colqui, Jaimis S. L.
    Filho, Jose Pissolato
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 236
  • [9] The Impact of Transmission Line Modeling on Lightning Overvoltage
    Leon Colqui, Jaimis Sajid
    Ribeiro de Moura, Rodolfo Antonio
    De Oliveira Schroeder, Marco Aurelio
    Pissolato Filho, Jose
    Kurokawa, Sergio
    ENERGIES, 2023, 16 (03)
  • [10] Lightning overvoltage analysis and calculation of 330kV overhead transmission line
    Zhang Xiubin
    Wen Dingjun
    Sun Yaming
    Chen Honggang
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1588 - 1591