An HPLC-SEC-based rapid quantification method for vesicular stomatitis virus particles to facilitate process development

被引:2
|
作者
Schimek, Adrian [1 ]
Ng, Judy K. M. [1 ]
Basbas, Ioannes [1 ]
Martin, Fabian [1 ]
Xin, Dongyue [2 ]
Saleh, David [3 ]
Hubbuch, Juergen [1 ,4 ]
机构
[1] ViraTherapeut GmbH, Bundesstr 27, A-6063 Rum, Austria
[2] Boehringer Ingelheim Pharmaceut Inc, 900 Ridgebury Rd, Ridgefield, CT 06877 USA
[3] Boehringer Ingelheim Pharma GmbH & Co KG, Birkendorfer Str 65, D-88397 Biberach, Germany
[4] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Sect Biomol Separat Engn 4, Fritz Haber Weg 2, D-76131 Karlsruhe, Germany
关键词
SIZE-EXCLUSION CHROMATOGRAPHY; MASS-SPECTROMETRY; QUANTITATION; CHALLENGES; TRACKING; SINGLE; CELLS;
D O I
10.1016/j.omtm.2024.101252
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Virus particle (VP) quantification plays a pivotal role in the development of production processes of VPs for virus-based therapies. The yield based on total VP count serves as a process performance indicator for evaluating process efficiency and consistency. Here, a label-free particle quantification method for enveloped VPs was developed, with potential applications in oncolytic virotherapy, vaccine development, and gene therapy. The method comprises size-exclusion chromatography (SEC) separation using high-performance liquid chromatography (HPLC) instruments. Ultraviolet (UV) was used for particle quantification and multi-angle light scattering (MALS) for particle characterization. Consistent recoveries of over 97% in the SEC were achieved upon mobile phase screenings and addition of bovine serum albumin (BSA) as sample stabilizer. A calibration curve was generated, and the method's performance and applicability to in-process samples were characterized. The assay's repeatability variation was <1% and its intermediate precision variation was <3%. The linear range of the method spans from 7.08 x 10(8) to 1.72 x 10(11) VP/mL, with a limit of detection (LOD) of 7.72 x 10(7) VP/mL and a lower limit of quantification (LLOQ) of 4.20 x 10(8) VP/mL. The method, characterized by its high precision, requires minimal hands-on time and provides same-day results, making it efficient for process development.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Phenolic compounds involved in pine wilt disease: HPLC-based method development and validation for their quantification
    Canas, Sara
    Trindade, Candida Sofia
    Sun, Baoshan
    Naves, Pedro
    JOURNAL OF PLANT BIOCHEMISTRY AND BIOTECHNOLOGY, 2021, 30 (02) : 343 - 353
  • [42] Development of a new HPLC-based method for 3-nitrotyrosine quantification in different biological matrices
    Teixeira, Dulce
    Prudencio, Cristina
    Vieira, Monica
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1046 : 48 - 57
  • [43] A recombinant vesicular stomatitis-based Lassa fever vaccine elicits rapid and long-term protection from lethal Lassa virus infection in guinea pigs
    Derek R. Stein
    Bryce M. Warner
    Geoff Soule
    Kevin Tierney
    Kathy L. Frost
    Stephanie Booth
    David Safronetz
    npj Vaccines, 4
  • [44] QbD based development of HPLC method for simultaneous quantification of Telmisartan and Hydrochlorothiazide impurities in tablets dosage form
    Palakurthi, Ashok K.
    Dongala, Thirupathi
    Katakam, Lakshmi Narasimha R.
    PRACTICAL LABORATORY MEDICINE, 2020, 21
  • [45] Phenolic compounds involved in pine wilt disease: HPLC-based method development and validation for their quantification
    Sara Canas
    Cândida Sofia Trindade
    Baoshan Sun
    Pedro Naves
    Journal of Plant Biochemistry and Biotechnology, 2021, 30 : 343 - 353
  • [46] Validation of a site-specific recombination cloning technique for the rapid development of a full-length cDNA clone of a virulent field strain of vesicular stomatitis New Jersey virus
    Velazquez-Salinas, Lauro
    Pauszek, Steven J.
    Barrera, Jose
    Clark, Benjamin A.
    Borca, Manuel, V
    Verdugo-Rodriguez, Antonio
    Stenfeldt, Carolina
    Arzt, Jonathan
    Rodriguez, Luis L.
    JOURNAL OF VIROLOGICAL METHODS, 2019, 265 : 113 - 116
  • [47] Evaluation of Neutralizing Antibodies Against Highly Pathogenic Coronaviruses: A Detailed Protocol for a Rapid Evaluation of Neutralizing Antibodies Using Vesicular Stomatitis Virus Pseudovirus-Based Assay
    Almahboub, Sarah A.
    Algaissi, Abdullah
    Alfaleh, Mohamed A.
    ElAssouli, M-Zaki
    Hashem, Anwar M.
    FRONTIERS IN MICROBIOLOGY, 2020, 11
  • [48] A recombinant vesicular stomatitis-based Lassa fever vaccine elicits rapid and long-term protection from lethal Lassa virus infection in guinea pigs
    Stein, Derek R.
    Warner, Bryce M.
    Soule, Geoff
    Tierney, Kevin
    Frost, Kathy L.
    Booth, Stephanie
    Safronetz, David
    NPJ VACCINES, 2019, 4 (1)
  • [49] Development of a simple and rapid HPLC-MS/MS method for quantification of streptomycin in mice and its application to plasma pharmacokinetic studies
    Wang, Zhijun
    Xie, Chen
    Yeung, Steven
    Wang, Jeffrey
    Chow, Moses S. S.
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (02)
  • [50] A rapid and highly sensitive HILIC-HPLC based analytical assay method for quantification of azacitidine and venetoclax in a single run
    More, Dnyaneshwar
    Khan, Nasir
    Sengupta, Pinaki
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2024, 47 (11-15) : 208 - 215