3D virtual patient-Magnetically retained printed stackable system for implant guided placement: Case report

被引:0
|
作者
Jreige, Camila Sales [1 ]
Gama, Rafael [2 ]
Parize, Hian [1 ]
Ates, Gokcen [2 ]
Sesma, Newton [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Prosthodont, 2227 Prof Lineu Prestes Ave, Sao Paulo, SP, Brazil
[2] Istanbul Univ, Dept Prosthodont, Istanbul, Turkiye
关键词
3D printing; dental implants; digital workflow; guided surgery; stackable guides; virtual patient; SURGERY;
D O I
10.1111/jerd.13265
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this report is to present the complete workflow of 3D virtual patient for planning and performing implant surgery with magnetically retained 3D-printed stackable guides. Clinical Considerations: A 3D-printed stackable system was proposed based on bone, dental, and facial references. Initially, a 66-year-old male patient was digitalized through photographs, cone beam computed tomography, and intraoral scans (Virtuo Vivo, Straumann). All files were merged to create a 3D virtual patient in the planning software (coDiagnostiX, Straumann). Sequential stackable guides were designed, printed, and cured. Magnets were inserted into connectors, and the interim protheses received color characterization. Four mounted guides were produced for the specific purposes of pin fixation, bone reduction, implant placement, and immediate provisionalization. After surgery and healing period, patient digital data were updated. Final implant positions were compared to planned values and inconsistencies were clinically acceptable. The mean angular deviation was 5.4 degrees (3.2-7.3) and mean 3D discrepancies were of 0.90 mm (0.46-1.12) at the entry point and 1.68 mm (1.00-2.20) at implant apex. Case follow-up revealed stability, patient's comfort, and no intercurrences. Conclusion: Magnetically retained stackable guides provide treatment accuracy and reduce surgical and prosthetic complications. The projected virtual patient enhances decision-making and communication between the multidisciplinary team and the patient, while decreases time and costs. Clinical SignificanceBidimensional diagnosis and freehand implant placement have limitations and outcomes often rely on professionals' expertise. Performing facially driven virtual planning improves treatment predictability. This approach promotes function, esthetic harmony, and patient satisfaction. Implant guided surgery and 3D printed prostheses constitute a reproducible digital workflow that can be implemented into clinical practice to optimize dental care.
引用
收藏
页码:1604 / 1613
页数:10
相关论文
共 50 条
  • [11] Auricular Reconstruction With Ultra-Short Dental Implant-retained Prosthesis: A Case Report on Virtual Planning Software and 3D Surgical Guides
    Song, Gun
    Park, Ji-su
    Jung, Seunggon
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (08) : e798 - e800
  • [12] 3D printed customised external cranial plate in a patient with syndrome of trephined: ‘a case report’
    Mee H.
    Greasley S.
    Whiting G.
    Harkin C.
    Oliver G.
    Marsden D.
    Andrews R.
    Sireau S.
    Price RD.
    Anwar F.
    Timofeev IS.
    Hutchinson PJ.
    White PA.
    Helmy A.
    3D Printing in Medicine, 7
  • [13] 3D printed customised external cranial plate in a patient with syndrome of trephined: 'a case report'
    Mee, H.
    Greasley, S.
    Whiting, G.
    Harkin, C.
    Oliver, G.
    Marsden, D.
    Andrews, R.
    Sireau, S.
    Price, R. D.
    Anwar, F.
    Timofeev, I. S.
    Hutchinson, P. J.
    White, P. A.
    Helmy, A.
    3D PRINTING IN MEDICINE, 2021, 7 (01)
  • [14] Computer-Guided Implant Placement: 3D Planning Software, Fixed Intraoral Reference Points, and CAD/CAM Technology. A Case Report
    Tahmaseb, Ali
    De Clerck, Renaat
    Wismeijer, Daniel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (03) : 541 - 546
  • [15] Fluoroless 3D mapping-guided pacemaker implant in a pregnant patient
    Gianni, Carola
    Della Rocca, Domenico G.
    Natale, Andrea
    Horton, Rodney P.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (09): : 1641 - 1645
  • [16] 3D PRINTED CUSTOMIZED CAD-CAM IMPLANT ABUTMENT FOR CORRECTION OF ANGULATED IMPLANT IN ESTHETIC ZONE-A CASE REPORT
    Maiti, Subhabrata
    Rai, Nitesh
    Appanna, Ponnanna
    Paulraj, Jessy
    ANNALS OF DENTAL SPECIALTY, 2023, 11 (02): : 1 - 6
  • [17] Methods Used to Assess the 3D Accuracy of Dental Implant Positions in Computer-Guided Implant Placement: A Review
    Pyo, Se-Wook
    Lim, Young-Jun
    Koo, Ki-Tae
    Lee, Jungwon
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (01)
  • [18] Accuracy of Implant Placement Utilizing 3D Printed and Thermoplastic Surgical Guides: A CBCT-Analysis
    Al-Hamdan, Khalid
    Al Oaibi, Abdulrahman
    AlWadai, Turki
    Al-Fadda, Abdullah
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (03): : 1210 - 1213
  • [19] The impact of 3D printed vs. 3D virtual congenital heart models on patient and family knowledge
    Zerwic, Luke
    Mohan, Ashray
    Riley, Emily
    Byeman, Connor
    Ashwath, Ravi
    FRONTIERS IN PEDIATRICS, 2025, 13
  • [20] Immediate implant-retained prosthetic obturation after maxillectomy based on zygomatic implant placement by 3D-guided surgery: a cadaver study
    Vosselman, N.
    Glas, H. H.
    de Visscher, S. A. H. J.
    Kraeima, J.
    Merema, B. J.
    Reintsema, H.
    Raghoebar, G. M.
    Witjes, M. J. H.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)