Limited versus full sternotomy for aortic valve replacement

被引:4
|
作者
Kirmani, Bilal H. [1 ,2 ,3 ]
Jones, Sion G. [4 ]
Muir, Andrew [1 ]
Malaisrie, S. Chris [5 ]
Chung, Darryl A. [6 ]
Williams, Richard J. N. N. [1 ]
Akowuah, Enoch [7 ,8 ]
机构
[1] Liverpool Heart & Chest Hosp, Cardiothorac Surg, Liverpool, Merseyside, England
[2] Univ Liverpool, Liverpool, Merseyside, England
[3] Liverpool Ctr Cardiovasc Sci, Liverpool, Merseyside, England
[4] Univ Hosp Coventry & Warwickshire, Dept Cardiac Surg, Coventry, W Midlands, England
[5] Northwestern Univ, Div Cardiac Surg, Chicago, IL USA
[6] High Lane Med Ctr, Stockport, Lancs, England
[7] South Tees Hosp NHS Fdn Trust, Acad Cardiovasc Unit, Middlesbrough, Cleveland, England
[8] Newcastle Univ, Translat & Clin Res Inst, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Aortic Valve [surgery; Aortic Valve Disease; Pain; Prospective Studies; Quality of Life; Randomized Controlled Trials as Topic; Retrospective Studies; State Medicine; Sternotomy [adverse eIects; Surgical Wound; QUALITY-OF-LIFE; MINIMALLY INVASIVE APPROACH; VALVULAR HEART-DISEASE; CONVENTIONAL STERNOTOMY; MEDIAN STERNOTOMY; MINI-STERNOTOMY; PORT-ACCESS; RIGHT MINITHORACOTOMY; PULMONARY-FUNCTION; RAPID DEPLOYMENT;
D O I
10.1002/14651858.CD011793.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Aortic valve disease is a common condition easily treatable with cardiac surgery. This is conventionally performed by opening the sternum ('median sternotomy') and replacing the valve under cardiopulmonary bypass. Median sternotomy is well tolerated, but as less invasive options become available, the efficacy of limited incisions has been called into question. In particular, the effects of reducing the visibility and surgical access have raised safety concerns with regard to the placement of cannulae, venting of the heart, epicardial wire placement, and de-airing of the heart at the end of the procedure. These difficulties may increase operating times, affecting outcome. The benefits of smaller incisions are thought to include decreased pain; improved respiratory mechanics; reductions in wound infections, bleeding, and need for transfusion; shorter intensive care stay; better cosmesis; and a quicker return to normal activity. This is an update of a Cochrane review first published in 2017, with seven new studies. Objectives To assess the effects of minimally invasive aortic valve replacement via a limited sternotomy versus conventional aortic valve replacement via median sternotomy in people with aortic valve disease requiring surgical replacement. Search methods We performed searches of CENTRAL, MEDLINE and Embase from inception to August 2021, with no language limitations. We also searched two clinical trials registries and manufacturers' websites. We reviewed references of primary studies to identify any further studies of relevance. Selection criteria We included randomised controlled trials comparing aortic valve replacement via a median sternotomy versus aortic valve replacement via a limited sternotomy. We excluded trials that performed other minimally invasive incisions such as mini-thoracotomies, port access, transapical, transfemoral or robotic procedures. Although some well-conducted prospective and retrospective case-control and cohort studies exist, these were not included in this review. Data collection and analysis Two review authors independently assessed trial papers to extract data, assess quality, and identify risk of bias. A third review author provided arbitration where required. We determined the certainty of evidence using the GRADE methodology and summarised results of patient-relevant outcomes in a summary of findings table. Main results The review included 14 trials with 1395 participants. Most studies had at least two domains at high risk of bias. We analysed 14 outcomes investigating the effects of minimally invasive limited upper hemi-sternotomy on aortic valve replacement as compared to surgery performed via full median sternotomy. Upper hemi-sternotomy may have little to no effect on mortality versus full median sternotomy (risk ratio (RR) 0.93, 95% confidence interval (CI) 0.45 to 1.94; 10 studies, 985 participants; low-certainty evidence). Upper hemi-sternotomy for aortic valve replacement may increase cardiopulmonary bypass time slightly, although the evidence is very uncertain (mean difference (MD) 10.63 minutes, 95% CI 3.39 to 17.88; 10 studies, 1043 participants; very low-certainty evidence) and may increase aortic cross-clamp time slightly (MD 6.07 minutes, 95% CI 0.79 to 11.35; 12 studies, 1235 participants; very low-certainty evidence), although the evidence is very uncertain. Most studies had at least two domains at high risk of bias. Postoperative blood loss was probably lower in the upper hemi-sternotomy group (MD -153 mL, 95% CI -246 to -60; 8 studies, 767 participants; moderate-certainty evidence). Low-certainty evidence suggested that there may be no change in pain scores by upper hemi-sternotomy (standardised mean difference (SMD) -0.19, 95% CI -0.43 to 0.04; 5 studies, 649 participants). Upper hemi-sternotomy may result in little to no difference in quality of life (MD 0.03 higher, 95% CI 0 to 0.06 higher; 4 studies, 624 participants; low-certainty evidence). Two studies reporting index admission costs concluded that limited sternotomy may be more costly at index admission in the UK National Health Service (MD 1190 GBP more, 95% CI 420 GBP to 1970 GBP, 2 studies, 492 participants; low-certainty evidence). Authors' conclusions The evidence was of very low to moderate certainty. Sample sizes were small and underpowered to demonstrate differences in some outcomes. Clinical heterogeneity was also noted. Considering these limitations, there may be little to no effect on mortality. Differences in extracorporeal support times are uncertain, comparing upper hemi-sternotomy to full sternotomy for aortic valve replacement. Before widespread adoption of the minimally invasive approach can be recommended, there is a need for a well-designed and adequately powered prospective randomised controlled trial. Such a study would benefit from also performing a robust cost analysis. Growing patient preference for minimally invasive techniques merits thorough quality of life analyses to be included as end points, as well as quantitative measures of physiological reserve.
引用
收藏
页数:75
相关论文
共 50 条
  • [31] The economic value of rapid deployment aortic valve replacement via full sternotomy
    Moore, Matt
    Barnhart, Glenn R.
    Chitwood, W. Randolph, Jr.
    Rizzo, John A.
    Gunnarsson, Candace
    Palli, Swetha R.
    Grossi, Eugene A.
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2017, 6 (04) : 293 - 302
  • [32] A Randomized Multicenter Trial of Minimally Invasive Rapid Deployment Versus Conventional Full Sternotomy Aortic Valve Replacement
    Borger, Michael A.
    Moustafine, Vadim
    Conradi, Lenard
    Knosalla, Christoph
    Richter, Markus
    Merk, Denis R.
    Doenst, Torsten
    Hammerschmidt, Robert
    Treede, Hendrik
    Dohmen, Pascal
    Strauch, Justus T.
    ANNALS OF THORACIC SURGERY, 2015, 99 (01): : 17 - 24
  • [33] Minithoracotomy versus full sternotomy for isolated aortic valve replacement: Propensity matched data from two centers
    Meyer, Alexander
    van Kampen, Antonia
    Kiefer, Philipp
    Sundermann, Simon
    Van Praet, Karel M.
    Borger, Michael A.
    Falk, Volkmar
    Kempfert, Jorg
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (01) : 97 - 104
  • [34] Partial versus Complete Sternotomy for Aortic Valve Replacement-Multicenter Study
    Goebel, Nora
    Stankowski, Tomasz
    Pollari, Francesco
    Hassan, Kambiz
    Jueckstock, Helena
    Schubel, Jens
    Sellin, Christian
    Zielezinski, Thorsten
    Elhmidi, Yacine
    Sack, Falk-Udo
    Feyrer, Richard
    Doerge, Hilmar
    Hausmann, Harald
    Massoudy, Parwis
    Schmoeckel, Michael
    Hakmi, Samer
    Fischlein, Theodor
    Fritzsche, Dirk
    Franke, Ulrich F. W.
    THORACIC AND CARDIOVASCULAR SURGEON, 2024,
  • [35] Ministernotomy versus median sternotomy for aortic valve replacement:: A prospective, randomized study
    Aris, A
    Cámara, ML
    Montiel, J
    Delgado, LJ
    Galán, J
    Litvan, H
    ANNALS OF THORACIC SURGERY, 1999, 67 (06): : 1583 - 1587
  • [36] Should Mini-Sternotomy Be Favoured Over Conventional Full-Sternotomy Approach in Aortic Valve Replacement
    Aljanadi, F.
    Moawad, N.
    Beattie, G.
    Nzewi, O.
    Jones, M.
    Ahmed, A.
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [37] Partial upper sternotomy for aortic valve replacement provides similar mid-term outcomes as the full sternotomy
    Hlavicka, Jan
    Janda, David
    Budera, Petr
    Tousek, Petr
    Maly, Marek
    Fojt, Richard
    Linkova, Hana
    Holubec, Tomas
    Racer, Petr
    JOURNAL OF THORACIC DISEASE, 2022, 14 (04) : 857 - 865
  • [38] Comparing mini-sternotomy to full median sternotomy for aortic valve replacement with propensity-matching methods
    Liu, Rui
    Song, Jiangping
    Chu, Junmin
    Hu, Shengshou
    Wang, Xian-qiang
    FRONTIERS IN SURGERY, 2022, 9
  • [39] Aortic Valve Replacement in Heart Failure Patients: Full Sternotomy or Minimally Invasive Access?
    Lehmann, Sven
    Leontyev, Sergey
    Etz, Christian D.
    Funkat, Anna
    Garbade, Jens
    Misfeld, Martin
    Borger, Michael
    Mohr, Friedrich W.
    CARDIOLOGY, 2014, 128 (02) : 116 - 117
  • [40] Postoperative Quality of Life After Full-sternotomy and Ministernotomy Aortic Valve Replacement
    Perrotti, Andrea
    Francica, Alessandra
    Monaco, Francesco
    Quintana, Edward
    Sponga, Sandro
    El-Dean, Zein
    Salizzoni, Stefano
    Loizzo, Tommaso
    Salsano, Antonio
    Di Cesare, Alessandro
    Benassi, Filippo
    Castella, Manuel
    Rinaldi, Mauro
    Chocron, Sidney
    Vendramin, Igor
    Faggian, Giuseppe
    Santini, Francesco
    Nicolini, Francesco
    Milano, Aldo Domenico
    Ruggieri, Vito Giovanni
    Onorati, Francesco
    ANNALS OF THORACIC SURGERY, 2023, 115 (05): : 1189 - 1196