摘要
BackgroundLinear attenuation coefficients (LACs) in positron emission tomography combined with computed tomography (PET/CT) are derived from CT scans that utilize energy-integrating detectors (EID-CT). These LACs are inaccurate when iodine contrast has been injected. Photon counting detector CT (PCD-CT) may be able to improve the accuracy.PurposeTo investigate whether PCD-CT can improve PET/CT quantitative accuracy.MethodsTwo experiments were performed: one with CT only and one that combined PET and CT. The first experiment used an electron density phantom whose inserts were imaged with EID-CT and PCD-CT. The inserts simulated normal human tissues, including bone and iodinated blood. In the case of PCD-CT, virtual-monoenergetic images at 190 keV were created. LACs were derived in each case and compared against known values. For inserts with iodine, more accurate LACs were expected with PCD-CT. The second experiment involved a custom PET phantom with various materials simulating human tissues (blood, iodinated blood, and bone) and 18F radioactivity. Data were first acquired with an EID-CT-based PET/CT system and then separately in a PCD-CT system without PET. PET images were reconstructed using LAC from EID-CT and PCD-CT. PET image values were compared against known activity values using recovery coefficients (RC).ResultsIn the first experiment, LAC based on EID-CT were in error by as much as 18%, whereas the corresponding PCD-CT based measurements were within 3%. In the second experiment, minimum, maximum, and mean RC were (96.1%, 115.4%, and 103.8%) for the EID-CT method, and (95.8%, 105.5%, and 101.0%) for the PCD-CT method. The consistency of PET images in body and head orientations was improved.ConclusionsPCD-CT can acquire the information needed for accurate LAC for PET reconstruction in a single spiral acquisition.
引用
收藏
页码:7206 / 7213
页数:8
相关论文
共 50 条
  • [41] GATED PHOTON-COUNTING CAN IMPROVE OPTICAL MEASUREMENTS
    PEASE, JS
    WANG, JC
    LASER FOCUS-ELECTRO-OPTICS, 1988, 24 (02): : 102 - &
  • [42] Accuracy and variability of radiomics in photon-counting CT: texture features and lung lesion morphology
    Rajagopal, Jayasai R.
    Hoye, Jocelyn
    Robins, Marthony
    Jones, Elizabeth C.
    Samei, Ehsan
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [43] Advantages of Photon-Counting Detector CT in Aortic Imaging
    Zanon, Chiara
    Cademartiri, Filippo
    Toniolo, Alessandro
    Bini, Costanza
    Clemente, Alberto
    Colacchio, Elda Chiara
    Cabrelle, Giulio
    Mastro, Florinda
    Antonello, Michele
    Quaia, Emilio
    Pepe, Alessia
    TOMOGRAPHY, 2024, 10 (01) : 1 - 13
  • [44] First human imaging with MARS photon-counting CT
    Panta, Raj Kumar
    Butler, Anthony P. H.
    Butler, Philip H.
    de Ruiter, Niels J. A.
    Bell, Stephen T.
    Walsh, Michael F.
    Doesburg, Robert M. N.
    Chernoglazov, Alexander, I
    Goulter, Brian P.
    Carbonez, Pierre
    Damet, Jerome
    Adebileje, Sikiru A.
    Alexander, Steven D.
    Amma, Maya R.
    Anjomrouz, Marzieh
    Asghariomabad, Fatemeh
    Atharifard, Ali
    Baer, Kenzie
    Bamford, Benjamin
    Bheesette, Srinidhi
    Chambers, Claire
    Dahal, Shishir
    Dalefield, Tara
    Duncan, Neryda
    Gieseg, Steven P.
    Gurney, Sam
    Healy, Joseph L.
    Hilton, Peter J.
    Kanithi, Preveenkumar
    Kirkbride, Tracy
    Lansley, Stuart P.
    Lowe, Chiara
    Mandalika, V. B. H.
    Marfo, Emmanuel
    Matanaghi, Aysouda
    Moghiseh, Mandieh
    Palmer, David
    Prebble, Hannah M.
    Raja, Aamir Y.
    Ramyar, Mohsen
    Renaud, Peter
    Schleich, Nanette
    Searle, Emily
    Shamshad, Muhammad
    Sheeja, Jereena S.
    Uddin, Rayhan
    Vanden Broeke, Lieza
    Vivek, V. S.
    Walker, E. Peter
    Wijesooriya, Manoj
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [45] Deep Grid Inpainting for Photon-Counting CT Detectors
    Magonov, Jan
    Maier, Joscha
    Fournie, Eric
    Sunnegardh, Johan
    Stierstorfer, Karl
    Kachelriess, Marc
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [46] MSK - Myeloma Diagnostics with Photon-Counting Detector CT
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (11): : 976 - +
  • [47] CT technology: photon-counting detector computed tomography
    Layer, Yannik Christian
    Kravchenko, Dmitrij
    Dell, Tatjana
    Kuetting, Daniel
    RADIOLOGIE, 2023, 63 (07): : 497 - 506
  • [48] Exploiting the Potential of Photon-Counting CT in Abdominal Imaging
    Schwartz, Fides Regina
    Samei, Ehsan
    Marin, Daniele
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 488 - 498
  • [49] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [50] Photon-counting cine-cardiac CT in the mouse
    Clark, Darin P.
    Holbrook, Matthew
    Lee, Chang-Lung
    Badea, Cristian T.
    PLOS ONE, 2019, 14 (09):