Technical note: Can photon-counting CT improve PET/CT's quantitative accuracy?

被引:1
|
作者
Hamill, James [1 ]
Birge, Noah [1 ]
O'Doherty, Jim [2 ,3 ]
Nye, Jonathon [4 ]
Elojeimy, Saeed [4 ]
机构
[1] Siemens Med Solut USA, 810 Innovat Dr Knoxville, Tennessee, IL 37923 USA
[2] Siemens Med Solut USA, CT R&D Collaborat, Malvern, PA USA
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC USA
[4] Med Univ South Carolina, Dept Radiol & Radiol Sci, Dept Nucl Med, Charleston, SC USA
关键词
attenuation correction; PET; photon-counting CT; ATTENUATION CORRECTION; INTRAVENOUS CONTRAST;
D O I
10.1002/mp.17299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundLinear attenuation coefficients (LACs) in positron emission tomography combined with computed tomography (PET/CT) are derived from CT scans that utilize energy-integrating detectors (EID-CT). These LACs are inaccurate when iodine contrast has been injected. Photon counting detector CT (PCD-CT) may be able to improve the accuracy.PurposeTo investigate whether PCD-CT can improve PET/CT quantitative accuracy.MethodsTwo experiments were performed: one with CT only and one that combined PET and CT. The first experiment used an electron density phantom whose inserts were imaged with EID-CT and PCD-CT. The inserts simulated normal human tissues, including bone and iodinated blood. In the case of PCD-CT, virtual-monoenergetic images at 190 keV were created. LACs were derived in each case and compared against known values. For inserts with iodine, more accurate LACs were expected with PCD-CT. The second experiment involved a custom PET phantom with various materials simulating human tissues (blood, iodinated blood, and bone) and 18F radioactivity. Data were first acquired with an EID-CT-based PET/CT system and then separately in a PCD-CT system without PET. PET images were reconstructed using LAC from EID-CT and PCD-CT. PET image values were compared against known activity values using recovery coefficients (RC).ResultsIn the first experiment, LAC based on EID-CT were in error by as much as 18%, whereas the corresponding PCD-CT based measurements were within 3%. In the second experiment, minimum, maximum, and mean RC were (96.1%, 115.4%, and 103.8%) for the EID-CT method, and (95.8%, 105.5%, and 101.0%) for the PCD-CT method. The consistency of PET images in body and head orientations was improved.ConclusionsPCD-CT can acquire the information needed for accurate LAC for PET reconstruction in a single spiral acquisition.
引用
收藏
页码:7206 / 7213
页数:8
相关论文
共 50 条
  • [1] Can photon-counting CT improve PET/CT's quantitative accuracy?
    Hamill, Jim
    O'Doherty, Jim
    Nye, Jonathon
    Elojeimy, Saeed
    Birge, Noah
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [2] The technical development of photon-counting detector CT
    Cynthia H. McCollough
    Kishore Rajendran
    Shuai Leng
    Lifeng Yu
    Joel G. Fletcher
    Karl Stierstorfer
    Thomas G. Flohr
    European Radiology, 2023, 33 : 5321 - 5330
  • [3] The technical development of photon-counting detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    Stierstorfer, Karl
    Flohr, Thomas G.
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5321 - 5330
  • [4] Can Photon-Counting CT Improve Estimation Accuracy of Morphological Radiomics Features? A Simulation Study for Assessing the Quantitative Benefits from Improved Spatial Resolution in Deep Silicon-Based Photon-Counting CT
    Sharma, Shobhit
    Pal, Debashish
    Abadi, Ehsan
    Sauer, Thomas
    Segars, Paul
    Hsieh, Jiang
    Samei, Ehsan
    ACADEMIC RADIOLOGY, 2023, 30 (06) : 1153 - 1163
  • [5] Technical Basics and Clinical Benefits of Photon-Counting CT
    Flohr, Thomas
    Schmidt, Bernhard
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 441 - 450
  • [6] Photon-counting CT: Technical Principles and Clinical Prospects
    Willemink, Martin J.
    Persson, Mats
    Pourmorteza, Amir
    Pelc, Norbert.
    Fleischmann, Dominik
    RADIOLOGY, 2018, 289 (02) : 293 - 312
  • [7] Photon-counting CT: Scouting for Quantitative Imaging Biomarkers
    Pourmorteza, Amir
    RADIOLOGY, 2021, 298 (01) : 153 - 154
  • [8] Standardization and Quantitative Imaging With Photon-Counting Detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 451 - 458
  • [9] Accuracy Assessment of Photon-Counting CT for Dose Calculation in Photon Therapy
    Wu, X.
    Shah, J.
    Wohlfahrt, P.
    Wu, Q.
    Wu, Q. J.
    Sheng, Y.
    MEDICAL PHYSICS, 2024, 51 (10) : 7669 - 7669
  • [10] Fundamentals of Photon-Counting CT
    Tang, Xiangyang
    Maltz, J.
    Rajendran, K.
    MEDICAL PHYSICS, 2022, 49 (06) : E541 - E542