Fat suppression using frequency-sweep RF saturation and iterative reconstruction

被引:0
|
作者
Zi, Ruoxun [1 ]
Benkert, Thomas [1 ]
Chandarana, Hersh [1 ]
Lattanzi, Riccardo [1 ]
Block, Kai Tobias [1 ]
机构
[1] NYU, Bernard & Irene Schwartz Ctr Biomed Imaging, Grossman Sch Med, Dept Radiol, New York, NY 10010 USA
基金
美国国家卫生研究院;
关键词
fat suppression; iterative reconstruction; low field; STEADY-STATE; MRI;
D O I
10.1002/mrm.30199
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To introduce an alternative idea for fat suppression that is suited both for low-field applications where conventional fat-suppression approaches become ineffective due to narrow spectral separation and for applications with strong B0 homogeneities. Methods: Separation of fat and water is achieved by sweeping the frequency of RF saturation pulses during continuous radial acquisition and calculating frequency-resolved images using regularized iterative reconstruction. Voxel-wise signal-response curves are extracted that reflect tissue's response to RF saturation at different frequencies and allow the classification into fat or water. This information is then utilized to generate water-only composite images. The principle is demonstrated in free-breathing abdominal and neck examinations using stack-of-stars 3D balanced SSFP (bSSFP) and gradient-recalled echo (GRE) sequences at 0.55 and 3T. Moreover, a potential extension toward quantitative fat/water separation is described. Results: Experiments with a proton density fat fraction (PDFF) phantom validated the reliability of fat/water separation using signal-response curves. As demonstrated for abdominal imaging at 0.55T, the approach resulted in more uniform fat suppression without loss of water signal and in improved CSF-to-fat signal ratio. Moreover, the approach provided consistent fat suppression in 3T neck exams where conventional spectrally-selective fat saturation failed due to strong local B0 inhomogeneities. The feasibility of simultaneous fat/water quantification has been demonstrated in a PDFF phantom. Conclusion: The proposed principle achieves reliable fat suppression in low-field applications and adapts to high-field applications with strong B0 inhomogeneity. Moreover, the principle potentially provides a basis for developing an alternative approach for PDFF quantification.
引用
收藏
页码:1995 / 2006
页数:12
相关论文
共 33 条
  • [21] Simultaneous optical and RF linear frequency sweep generation using a Fourier domain mode-locked OEO with carrier-suppressed sideband modulation
    Hao, Peng
    Wan, Zhenchuan
    Bi, Ruixue
    Gong, Haocong
    Yao, X. Steve
    OPTICS EXPRESS, 2024, 32 (18): : 32175 - 32186
  • [22] Instability of background fat intensity suppression using fat-saturated (FS) MR imaging techniques according to region and reconstruction procedure in patients with oral cancer
    Morimoto, Y
    Tanaka, T
    Kito, S
    Yoshioka, I
    Shibuya, T
    Okabe, Y
    Matsufuji, Y
    Ohba, T
    ORAL ONCOLOGY, 2004, 40 (03) : 332 - 340
  • [23] Correction of Excitation Profile in Zero Echo Time (ZTE) Imaging Using Quadratic Phase-Modulated RF Pulse Excitation and Iterative Reconstruction
    Li, Cheng
    Magland, Jeremy F.
    Seifert, Alan C.
    Wehrli, Felix W.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (04) : 961 - 969
  • [24] Reduced Field-of-View DWI with Robust Fat Suppression and Unrestricted Slice Coverage Using Tilted 2D RF Excitation
    Banerjee, Suchandrima
    Nishimura, Dwight G.
    Shankaranarayanan, Ajit
    Saritas, Emine Ulku
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (06) : 1668 - 1676
  • [25] Amide Proton Transfer Imaging With Improved Robustness to Magnetic Field Inhomogeneity and Magnetization Transfer Asymmetry Using Saturation With Frequency Alternating RF Irradiation
    Scheidegger, Rachel
    Vinogradov, Elena
    Alsop, David C.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) : 1275 - 1285
  • [26] Effectiveness of fat suppression using a water-selective binomial-pulse excitation in chemical exchange saturation transfer (CEST) magnetic resonance imaging
    Zhao, Yu
    Zu, Zhongliang
    Wang, Zhichao
    Liu, Zhenzhi
    Guo, Bin
    Yan, Xu
    Gochberg, Daniel F.
    Li, Jianqi
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (06) : 809 - 818
  • [27] Effectiveness of fat suppression using a water-selective binomial-pulse excitation in chemical exchange saturation transfer (CEST) magnetic resonance imaging
    Yu Zhao
    Zhongliang Zu
    Zhichao Wang
    Zhenzhi Liu
    Bin Guo
    Xu Yan
    Daniel F. Gochberg
    Jianqi Li
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 809 - 818
  • [28] Assessment of the Quality of Breast MR Imaging Using the Modified Dixon Method and Frequency-selective Fat Suppression: A Phantom Study
    Takatsu, Yasuo
    Kyotani, Katsusuke
    Ueyama, Tsuyoshi
    Miyati, Tosiaki
    Yamamura, Kenichirou
    Andou, Atsushi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (04) : 350 - 355
  • [29] Suppression of RF noise tones caused by Rayleigh backscatter in to an unisolated laser using audio-frequency external optical-phase modulation
    Gan, HB
    Lowery, AJ
    Lauder, RDT
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1998, 10 (12) : 1778 - 1780
  • [30] CT-based thermometry with virtual monoenergetic images by dual-energy of fat, muscle and bone using FBP, iterative and deep learning–based reconstruction
    Andreas Heinrich
    Sebastian Schenkl
    David Buckreus
    Felix V. Güttler
    Ulf K-M. Teichgräber
    European Radiology, 2022, 32 : 424 - 431