Digital phantom versus patient-specific radiation dosimetry in adult routine thorax CT examinations

被引:2
|
作者
Papadakis, Antonios E. [1 ]
Giannakaki, Vassiliki [1 ]
Stratakis, John [1 ]
Myronakis, Marios [1 ]
Zaidi, Habib [2 ,3 ,4 ,5 ]
Damilakis, John [6 ]
机构
[1] Univ Hosp Heraklion, Med Phys Dept, Iraklion, Crete, Greece
[2] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, Geneva, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[4] Univ Southern Denmark, Dept Nucl Med, Odense, Denmark
[5] Obuda Univ, Univ Res & Innovat Ctr, Budapest, Hungary
[6] Univ Crete, Med Sch, Med Phys Dept, Iraklion, Crete, Greece
来源
关键词
CT; digital phantoms; dosimetry; experimental phantoms; Monte Carlo; HYBRID COMPUTATIONAL PHANTOMS; PEDIATRIC CHEST; VALIDATION; FAMILY; RISK;
D O I
10.1002/acm2.14389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe aim of this study was to compare the organ doses assessed through a digital phantom-based and a patient specific-based dosimetric tool in adult routine thorax computed tomography (CT) examinations with reference to physical dose measurements performed in anthropomorphic phantoms.MethodsTwo Monte Carlo based dose calculation tools were used to assess organ doses in routine adult thorax CT examinations. These were a digital phantom-based dosimetry tool (NCICT, National Cancer Institute, USA) and a patient-specific individualized dosimetry tool (ImpactMC, CT Imaging GmbH, Germany). Digital phantoms and patients were classified in four groups according to their water equivalent diameter (Dw). Normalized to volume computed tomography dose index (CTDIvol), organ dose was assessed for lungs, esophagus, heart, breast, active bone marrow, and skin. Organ doses were compared to measurements performed using thermoluminescent detectors (TLDs) in two physical anthropomorphic phantoms that simulate the average adult individual as a male (Alderson Research Labs, USA) and as a female (ATOM Phantoms, USA).ResultsThe average percent difference of NCICT to TLD and ImpactMC to TLD dose measurements across all organs in both sexes was 13% and 6%, respectively. The average +/- 1 standard deviation in dose values across all organs with NCICT, ImpactMC, and TLDs was +/- 0.06 (mGy/mGy), +/- 0.19 (mGy/mGy), and +/- 0.13 (mGy/mGy), respectively. Organ doses decreased with increasing Dw in both NCICT and ImpactMC.ConclusionOrgan doses estimated with ImpactMC were in closer agreement to TLDs compared to NCICT. This may be attributed to the inherent property of ImpactMC methodology to generate phantoms that resemble the realistic anatomy of the examined patient as opposed to NCICT methodology that incorporates an anatomical discrepancy between phantoms and patients.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Patient-Specific Dosimetry for CT Examinations in the Pediatric Population
    Carver, D.
    Kost, S.
    Clark, J.
    Price, R.
    Pickens, D.
    Stabin, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3607 - 3607
  • [2] Additively Manufactured Patient-Specific Anthropomorphic Thorax Phantom With Realistic Radiation Attenuation Properties
    Hatamikia, Sepideh
    Oberoi, Gunpreet
    Unger, Ewald
    Kronreif, Gernot
    Kettenbach, Joachim
    Buschmann, Martin
    Figl, Michael
    Knaeusl, Barbara
    Moscato, Francesco
    Birkfellner, Wolfgang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [3] Design and manufacture of a patient-specific phantom for Dosimetry analysis
    Gear, J. I.
    Cummings, C.
    Partridge, M.
    Flux, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S178 - S178
  • [4] Implementation of Dosimetrix® for patient-specific dosimetry in clinical routine
    Combettes, E.
    Deshayes, E.
    Santoro, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S221 - S221
  • [5] Evaluation of patient-specific MC simulation accuracy with the XCAT phantom results in PET/CT patient dosimetry
    Karimipourfard, M.
    Sina, S.
    Shoshtari, F. Khodadadi
    Mahani, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S632 - S633
  • [6] Phantom-and patient-specific dose calculations for CT
    Schmidt, B
    Kalender, WA
    RADIOLOGY, 2002, 225 : 592 - 592
  • [7] Patient-specific CT dosimetry calculation: a feasibility study
    Fearon, Thomas
    Xie, Huchen
    Cheng, Jason Y.
    Ning, Holly
    Zhuge, Ying
    Miller, Robert W.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 196 - 209
  • [8] A 4D digital phantom for patient-specific simulation of brain CT perfusion protocols
    van den Boom, Rieneke
    Manniesing, Rashindra
    Oei, Marcel T. H.
    van der Woude, Willem-Jan
    Smit, Ewoud J.
    Laue, Hendrik O. A.
    van Ginneken, Bram
    Prokop, Mathias
    MEDICAL PHYSICS, 2014, 41 (07)
  • [9] Patient-specific fetal radiation dosimetry for pregnant patients undergoing abdominal and pelvic CT imaging
    Qu, Shuiyin
    Liu, Haikuan
    Xie, Tianwu
    Giger, Maryellen L.
    Quan, Guotao
    Zaidi, Habib
    MEDICAL PHYSICS, 2023, 50 (06) : 3801 - 3815
  • [10] Evaluation of a patient-specific Monte Carlo software for CT dosimetry
    Myronakis, Marios
    Perisinakis, Kostas
    Tzedakis, Antonis
    Gourtsoyianni, Sofia
    Damilakis, John
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 248 - 255