A novel dynamic interferometric measurement method based on liquid level reference

被引:0
|
作者
Yuan, Yufeng [1 ]
Ong, S. K. [2 ]
Yin, Yuehong [1 ]
He, Yueqi [1 ]
Qiu, Junyang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Robot Inst, Sch Mech Engn, Shanghai, Peoples R China
[2] Natl Univ Singapore, Coll Design & Engn, Mech Engn Dept, Singapore, Singapore
关键词
Measurement; Interferometer; Liquid level reference;
D O I
10.1016/j.cirp.2024.04.0700007-8506
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dynamic optical interferometric measurement method directly uses the liquid level as the reference surface, which immerses the tested object in liquid, and the interferograms are generated based on the optical path difference between the surfaces of the liquid and the object. The phase shift is realized by adjusting the incident angle of the laser with a rotation reflector. A generalized inhomogeneous phase shift algorithm is developed to suppress the micro-vibration of the liquid surface by the iterative least squares method combined with a confidence matrix. The high performance of the proposed method has been well verified in simulation and experiment. (c) 2024 Published by Elsevier Ltd on behalf of CIRP.
引用
收藏
页码:397 / 400
页数:4
相关论文
共 50 条
  • [41] A novel helical electrode type capacitance level sensor for liquid level measurement
    Hanni, Jayalaxmi Rajesh
    Venkata, Santhosh Krishnan
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 315
  • [42] Concept for a novel grain level measurement method in silos
    Isiker, Hakan
    Canbolat, Hueseyin
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2009, 65 (02) : 258 - 267
  • [43] Interferometric method - a novel method to study the migration
    Guan, Dalin
    Gu, Qijang
    Huozhayao Xuebao/Chinese Journal of Explosives & Propellants, 22 (01): : 56 - 58
  • [44] A novel liquid level detection method and its implementation
    Musayev, E
    Karlik, SE
    SENSORS AND ACTUATORS A-PHYSICAL, 2003, 109 (1-2) : 21 - 24
  • [45] Reference measurement system for dynamic satellite based positioning experiments
    Däubler, L
    Filova, B
    Schrom, H
    TECHNISCHES MESSEN, 2002, 69 (03): : 125 - 130
  • [46] Polymer Optical Fiber Continuous Liquid Level Sensor for Dynamic Measurement
    Zhang, Hui-Xin
    Hou, Yu-Long
    Feng, Li-Shuang
    Su, Shan
    Zhang, Jia-Wei
    Liu, Jia
    Liu, Wen-Yi
    Liu, Jun
    Xiong, Ji-Jun
    IEEE SENSORS JOURNAL, 2015, 15 (09) : 5238 - 5242
  • [47] A method for linear distance measurement based on reference plane
    Wang, X.-P. (awangxp@163.com), 1600, Sichuan University (45):
  • [48] Novel method of evaluating dynamic repeated measurement uncertainty
    Wang Zhongyu
    Ge Leyi
    JOURNAL OF TESTING AND EVALUATION, 2008, 36 (05) : 453 - 459
  • [49] A NOVEL ELECTRONIC METHOD FOR DYNAMIC MEASUREMENT OF MICROVASCULAR DIAMETER
    YING, XY
    XIU, RJ
    FEDERATION PROCEEDINGS, 1986, 45 (04) : 1141 - 1141
  • [50] A novel method of fast dynamic optical image stabilization precision measurement based on CCD
    Li, Jing
    Wang, Junzheng
    Wang, Shoukun
    OPTIK, 2011, 122 (07): : 582 - 585