A theoretical and numerical analysis of solar chimney in multi-storey atrium building

被引:2
|
作者
Shi, Long [1 ,2 ,3 ]
Wu, Qihong [1 ]
Zhang, Guomin [3 ]
Wang, Qingyuan [1 ]
机构
[1] Chengdu Univ, Sch Architecture & Civil Engn, Chengdu 610106, Sichuan, Peoples R China
[2] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[3] RMIT Univ, Sch Engn, Civil & Infrastruct Engn Discipline, Melbourne 3001, Australia
基金
中国国家自然科学基金;
关键词
Solar energy; Low energy building; Natural ventilation; Trombe wall; Cost-effective solution; WHO ventilation requirement; NATURAL VENTILATION; EMPIRICAL-MODEL; TROMBE WALL; ONE-ZONE; PERFORMANCE; BUOYANCY; ROOM;
D O I
10.1016/j.seta.2024.103797
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Current research efforts on solar chimney are much on those configurations with single space or single vent, hampering its applications in complex buildings. To expand its implementation, the viability of solar chimney in multi-storey atrium buildings was explored numerically and theoretically. It was known that its natural ventilation performance can fulfil the WHO requirements ( i.e. , 6 air change per hour, ACH) even under low solar radiation of 200 W/m(2) if it is appropriately designed, such as cavity gap (d), cavity height (H-c), solar radiation (Q), and window width (W). Its natural ventilation rate was found to be positively linear to the exponential form of the analyzed factors in this study, including cavity gap ( d(0.63 similar to 0.69) ), cavity height (H-c(0.59 similar to 0.60) ), solar radiation (Q(0.42 similar to 0.43) ), and window width ( W-0.14 similar to 0.20 ). The impacts of cavity gap and solar radiation are relatively weaker for big space such as atrium than those scenarios with single-space ventilation in the literature. The volume of the connected space was found to affect its natural ventilation performance, where the obtained ventilation rate of 4storey is averagely 5.1 % lower than those of 3-storey buildings. A theoretical model was developed and experimentally validated, for the first time, to predict the natural ventilation rate of solar chimney when it is applied to the atrium with multiple air inlets. It was also noticed that the same theoretical model can be applied to the atrium buildings with odd and even storeys, but the area coefficients are different. The research outcomes of this study confirm the viability of solar chimney in complex buildings and offer a theoretical foundation for its implementation.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Wastewater recycling concept for an urban multi-storey building
    Herrmann, T
    Hesse, T
    WATER SCIENCE AND TECHNOLOGY, 2002, 46 (6-7) : 325 - 332
  • [32] Business models in industrialized building of multi-storey houses
    Brege, Staffan
    Stehn, Lars
    Nord, Tomas
    CONSTRUCTION MANAGEMENT AND ECONOMICS, 2014, 32 (1-2) : 208 - 226
  • [33] Comfort level identification for irregular multi-storey building
    Alqado, Tarek Edrees Saaed
    Nikolakopoulos, George
    Jonasson, Jan-Erik
    AUTOMATION IN CONSTRUCTION, 2015, 50 : 40 - 49
  • [34] Seismic Performance Assessment of a Conventional Multi-storey Building
    Giuseppe Marcantonio Del Gobbo
    Martin S. Williams
    Anthony Blakeborough
    International Journal of Disaster Risk Science, 2017, 8 : 237 - 245
  • [35] Multi-Storey Brick Building in Passive House Construction
    不详
    MAUERWERK, 2010, 14 (05) : 310 - 310
  • [36] The dynamic characteristics of a multi-storey steel framed building
    Ellis, BR
    Moore, DB
    Delpak, R
    Richards, VM
    Luke, S
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 235 - 240
  • [37] Seismic Performance Assessment of a Conventional Multi-storey Building
    Giuseppe Marcantonio Del Gobbo
    Martin S.Williams
    Anthony Blakeborough
    InternationalJournalofDisasterRiskScience, 2017, 8 (03) : 237 - 245
  • [38] Differential Movements in a Timber Multi-Storey Hybrid Building
    Meleki, H.
    Asiz, A.
    Smith, I.
    Gagnon, S.
    Mohammad, M.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14 : 1613 - 1620
  • [39] A complete timber building system for multi-storey buildings
    Daerga, Per-Anders
    Girhammar, Ulf Arne
    Kallsner, Bo
    CONSTRUCTION MATERIALS AND STRUCTURES, 2014, : 1164 - 1171
  • [40] Solar Chimney Effect in Building the Application Research of the Atrium
    Shi, Yanbo
    He, Mei
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ENERGY, 2013, : 91 - 95