Smartphone-enabled flow injection amperometric glucose monitoring based on a screen-printed carbon electrode modified with PEDOT@PB and a GOx@PPtNPs@MWCNTs nanocomposite

被引:2
|
作者
Khumngern, Suntisak [1 ,2 ]
Nontipichet, Natha [1 ]
Thavarungkul, Panote [1 ,2 ,3 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Ctr Excellence Trace Anal & Biosensor, Hat Yai 90110, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Div Phys Sci, Hat Yai 90110, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Ctr Excellence Innovat Chem, Hat Yai 90110, Songkhla, Thailand
关键词
Flow injection analysis; Electrochemical biosensor; Glucose detection; PPtNPs@MWCNTs nanocomposite; PEDOT@PB nanocomposite; PRUSSIAN BLUE; PLATINUM NANOPARTICLES; SENSOR; NANOSHEETS; OXIDASE; FILM;
D O I
10.1016/j.talanta.2024.126336
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents a modified screen-printed carbon electrode (SPCE) to determine glucose in a custom-built flow injection system. The biosensor was constructed by immobilizing glucose oxidase on porous platinum nanoparticles decorated on multi-walled carbon nanotubes (GOx@PPtNPs@MWCTNs). The fabrication of the biosensor was completed by coating the GOx@PPtNPs@MWCTNs nanocomposite on an SPCE modified with a nanocomposite of poly(3,4-ethylenedioxythiophene) and Prussian blue (GOx@PPtNPs@MWCTNs/PEDOT@PB/SPCE). The fabricated electrode accurately measured hydrogen peroxide (H2O2), the byproduct of the GOx-catalyzed oxidation of glucose, and was then applied as a glucose biosensor. The glucose response was amperometrically determined from the PB-mediated reduction of H2O2 at an applied potential of -0.10 V in a flow injection system. Under optimal conditions, the developed biosensor produced a linear range from 2.50 mu M to 1.250 mM, a limit of detection of 2.50 mu M, operational stability over 500 sample injections, and good selectivity. The proposed biosensor determined glucose in human plasma samples, achieving recoveries and results that agreed with the hexokinase-spectrophotometric method (P > 0.05). Combining the proposed biosensor with the custom-built sample feed, a portable potentiostat and a smartphone, enabled on-site glucose monitoring.
引用
收藏
页数:12
相关论文
共 18 条
  • [1] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [2] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [3] Flow injection amperometric uric acid biosensor based on AuNPs-GO-CS porous composite cryogel coated on PB-PEDOT:PSS modified screen-printed carbon electrode
    Tuntiwongmetee, Thanawath
    Khumngern, Suntisak
    Nontipichet, Natha
    Romportong, Supapich
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    BIOELECTROCHEMISTRY, 2024, 158
  • [4] An amperometric glucose biosensor based on a screen-printed electrode and Os-complex mediator for flow injection analysis
    Liu, Jian
    Sun, Shanhui
    Liu, Changchun
    Wei, Shoushui
    MEASUREMENT, 2011, 44 (10) : 1878 - 1883
  • [5] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    Bioelectrochemistry, 2021, 138
  • [6] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    BIOELECTROCHEMISTRY, 2021, 138
  • [7] An amperometric glucose biosensor based on layer-by-layer GOx-SWCNT conjugate/redox polymer multilayer on a screen-printed carbon electrode
    Gao, Qiang
    Guo, Yanyan
    Zhang, Wenyan
    Qi, Honglan
    Zhang, Chengxiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01): : 219 - 225
  • [8] A novel flow injection amperometric sensor based on carbon black and graphene oxide modified screen-printed carbon electrode for highly sensitive determination of uric acid
    Reanpang, Preeyaporn
    Mool-am-kha, Pijika
    Upan, Jantima
    Jakmunee, Jaroon
    TALANTA, 2021, 232
  • [9] Amperometric determination of bonded glucose with an MnO2 and glucose oxidase bulk-modified screen-printed electrode using flow-injection analysis
    Turkusic, E
    Kalcher, J
    Kahrovic, E
    Beyene, NW
    Moderegger, H
    Sofic, E
    Begic, S
    Kalcher, K
    TALANTA, 2005, 65 (02) : 559 - 564
  • [10] Ultrasensitive and highly stable nonenzymatic glucose sensor by a CuO/graphene-modified screen-printed carbon electrode integrated with flow-injection analysis
    Sun, Chia-Liang
    Cheng, Wan-Ling
    Hsu, Ting-Kang
    Chang, Chia-Wei
    Chang, Jen-Lin
    Zen, Jyh-Myng
    ELECTROCHEMISTRY COMMUNICATIONS, 2013, 30 : 91 - 94