A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode

被引:0
|
作者
Khumngern, Suntisak [1 ,2 ,3 ]
Jirakunakorn, Ratchaneekorn [1 ,2 ,3 ]
Thavarungkul, Panote [1 ,2 ,3 ]
Kanatharana, Proespichaya [1 ,2 ,3 ]
Numnuam, Apon [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Ctr Excellence Trace Anal & Biosensor, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Sci, Div Phys Sci, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Ctr Excellence Innovat Chem, Fac Sci, Hat Yai 90112, Songkhla, Thailand
关键词
Prussian blue; Glucose; Gold nanoparticles; Flow injection analysis; Polytyramine; PRUSSIAN-BLUE; HYDROGEN-PEROXIDE; ELECTROCHEMICAL DETECTION; HYBRID FILM; NANOPARTICLES; IMMOBILIZATION; OXIDASE; NANOCOMPOSITE; POLYTYRAMINE; SENSOR;
D O I
10.1016/j.bioelechem.2020.107718
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A novel oxidase enzyme sensor was fabricated based on the chemisorption of highly active glucose oxidase (GOx) on gold nanoparticles that were adsorbed on a polytyramine layer (AuNPs/Pty). The GOx/AuNPs/Pty assembly was coated on a Prussian blue (PB)-modified screen-printed carbon electrode (SPCE) to produce the GOx/AuNPs/Pty/PB/SPCE biosensor. The amperometric glucose biosensor response was measured at-0.10 V using a Ag pseudo-reference electrode through the reduction current of the PB mediator in a flow injection analysis system. Under optimised experimental conditions, the developed biosensor displayed linearity over the 1.0 mu M -1.0 mM glucose concentration range and a limit of detection of 1.0 mu M (S/N >= 3). A low value for the Michaelis constant of 0.21 mM indicated that the immobilised GOx had high affinity for glucose. The developed biosensor exhibited excellent operational stability over 374 injections, long-term stability over 3 weeks, good reproducibility (relative standard deviations = 1.9%-4.3%) and high selectivity. The results obtained analysing glucose in blood plasma samples were satisfactory when compared with the corresponding results recorded implementing the standard hexokinase-spectrophotometric method (P > 0.05). (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    [J]. Bioelectrochemistry, 2021, 138
  • [2] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    [J]. CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [3] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [4] Amperometric biosensor based on Prussian Blue nanoparticle-modified screen-printed electrode for estimation of glucose-6-phosphate
    Banerjee, Suchanda
    Sarkar, Priyabrata
    Turner, Anthony P. F.
    [J]. ANALYTICAL BIOCHEMISTRY, 2013, 439 (02) : 194 - 200
  • [5] Reagentless Amperometric Pyruvate Biosensor Based on a Prussian Blue- and Enzyme Nanoparticle-Modified Screen-Printed Carbon Electrode
    Thirumalai, Dinakaran
    Kim, Seonghye
    Kim, Suhkmann
    Chang, Seung-Cheol
    [J]. ACS OMEGA, 2020, 5 (46): : 30123 - 30129
  • [6] Amperometric biosensor based on Prussian Blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    Rejeb, Ines Ben
    Arduini, Fabiana
    Amine, Aziz
    Gargouri, Mohamed
    Palleschi, Giuseppe
    [J]. ANALYTICA CHIMICA ACTA, 2007, 594 (01) : 1 - 8
  • [8] A paper-based amperometric glucose biosensor developed with Prussian Blue-modified screen-printed electrodes
    Sekar, Nadia Chandra
    Shaegh, Seyed Ali Mousavi
    Ng, Sum Huan
    Ge, Liya
    Tan, Swee Ngin
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 414 - 420
  • [9] Flow injection analysis of an ultratrace amount of arsenite using a Prussian blue-modified screen-printed electrode
    Zen, JM
    Chen, PY
    Kumar, AS
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (21) : 6017 - 6022
  • [10] A Highly Sensitive Biosensor Based on a 3D Gold Nanostructure Modified Screen-Printed Electrode for Glucose Detection
    Liu, His-Chien
    Tsai, Chung-Che
    Chang, Kang J.
    Wang, Gou-Jen
    [J]. 2013 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2013,