Burn-in test and thermal performance evaluation of Silicon Photomultipliers for the JUNO-TAO experiment

被引:0
|
作者
Chen, X. [1 ]
Cao, G. F. [2 ,3 ]
Qu, M. H. [4 ]
Wang, H. W. [2 ]
Anfimov, N. [5 ]
Rybnikov, A. [5 ]
Xu, J. Y. [2 ,3 ]
Su, A. Q. [4 ]
Chen, Z. L. [1 ]
Cao, J. [2 ]
Li, Y. C. [2 ]
Qi, M. [1 ]
机构
[1] Nanjing Univ, 22 Hankou Rd, Nanjing 210093, Jiangsu, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, 19B Yuquan Rd, Beijing 100049, Peoples R China
[3] Univ Chinese Acad Sci, 1 Yanqihu East Rd, Beijing 101408, Peoples R China
[4] Zhengzhou Univ, 100 Sci Ave, Zhengzhou 450001, Henan, Peoples R China
[5] Joint Inst Nucl Res, 6 Joliot Curie Str, Dubna 141980, Moscow, Russia
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 07期
关键词
Analysis and statistical methods; Detector cooling and thermo-stabilization; Large detector-systems performance; Data processing methods;
D O I
10.1088/1748-0221/19/07/P07028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study evaluates more than 4,000 tiles made of Hamamatsu visual-sensitive silicon photomultipier (SiPM), each with dimensions of 5 x 5 cm2, 2 , intended for the central detector of the Taishan Anti-neutrino Observatory (TAO), a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO) aimed at measuring the reactor anti-neutrino energy spectrum with unprecedented energy resolution. All SiPM tiles underwent a room temperature burn-in test in the dark for two weeks, while cryogenic testing analyzed the thermal dependence of parameters for some sampled SiPMs. Results from these comprehensive tests provide crucial insights into the long-term performance and stability of the 10 square meters of SiPMs operating at -50 degrees C degrees C to detect scintillation photons in the TAO detector. Despite some anomalies awaiting further inspection, all SiPMs successfully passed the burn-in test over two weeks at room temperature, which is equivalent to 6.7 years at -50 degrees C. degrees C. Results are also used to guide optimal SiPM selection, configuration, and operation, ensuring reliability and sustainability in reactor neutrino measurements. This work also provides insights for a rapid and robust quality assessment in future experiments that employ large-scale SiPMs as detection systems.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Experiment test of atmospheric turbulence effects on the IR thermal imagers performance
    Wang, Chensheng
    Zhang, Zhijie
    Hong, Pu
    Wang, Qun
    INFRARED, MILLIMETER WAVE, AND TERAHERTZ TECHNOLOGIES, 2010, 7854
  • [22] Performance Evaluation of Silicon Photomultipliers for Frequency-Domain Fluorescence Lifetime Measurement Based on a Comprehensive Circuit Model
    Siminfar, Amir Reza
    Shoaci, Omid
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2019, 55 (05)
  • [23] High-Density Silicon Photomultipliers: Performance and Linearity Evaluation for High Efficiency and Dynamic-Range Applications
    Acerbi, Fabio
    Paternoster, Giovanni
    Gola, Alberto
    Regazzoni, Veronica
    Zorzi, Nicola
    Piemonte, Claudio
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 2018, 54 (02)
  • [24] Demonstration of hybrid silicon-on-silicon carbide wafers and electrical test structures with improved thermal performance
    Whipple, Steven G.
    Torvik, John T.
    Treece, Randolph E.
    Bernacki, Jeffrey T.
    SILICON CARBIDE 2006 - MATERIALS, PROCESSING AND DEVICES, 2006, 911 : 383 - +
  • [25] Assessing thermal comfort and performance in the workplace: A test room experiment for summer and winter conditions
    Carnieletto, Laura
    Marigo, Marco
    Arcelli, Tommaso
    Moro, Christian
    Turchi, Gian Piero
    De Carli, Michele
    Di Bella, Antonino
    BUILDING AND ENVIRONMENT, 2025, 276
  • [26] Application of the PSTAR method to a massive test cell for thermal performance evaluation
    Chun, WG
    Jeon, MS
    Yoon, HK
    Jeon, HS
    Auh, PC
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1997, 21 (02) : 129 - 138
  • [27] Development of an experimental test rig for the evaluation of the thermal performance of building roofs
    Michels, Caren
    Guths, Saulo
    Marinoski, Deivis L.
    Lamberts, Roberto
    ENERGY AND BUILDINGS, 2018, 180 : 32 - 41
  • [28] Fundamental evaluation of the performance field experiment and model experiment of air-conditioning system with floor thermal storage
    Dept. of Architecture, Waseda University, Japan
    不详
    J. Environ. Eng., 2009, 635 (63-70):
  • [29] SENSITIVITY EVALUATION OF THE DAILY THERMAL PREDICTIONS OF THE AGR-2 EXPERIMENT IN THE ADVANCED TEST REACTOR
    Hawkes, Grant L.
    Sterbentz, James W.
    Pham, Binh T.
    PROCEEDINGS OF THE ASME NUCLEAR FORUM - 2015, 2016,
  • [30] Thermal Conductivity Evaluation and Road Performance Test of Steel Slag Asphalt Mixture
    Cao, Yangsen
    Sha, Aimin
    Liu, Zhuangzhuang
    Zhang, Fan
    Li, Jiarong
    Liu, Hai
    SUSTAINABILITY, 2022, 14 (12)